Literature DB >> 20202762

Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius.

Matthew L Tweet1, Ryan P Calfee, Peter J Stern.   

Abstract

PURPOSE: Intra-articular screw penetration is one complication of volar plate fixation of distal radius fractures. This study was designed to determine the most commonly used imaging techniques and views during volar plating of distal radius fractures and to evaluate surgeons' ability to detect intra-articular screw placement on static fluoroscopic images and rotational fluoroscopy.
METHODS: Active members of the American Society for Surgery of the Hand were polled regarding preferred imaging techniques (fluoroscopic vs cassette radiographs) and views (rotational fluoroscopy or static orthogonal/anatomic tilt/semipronated imaging) during volar plating of distal radius fractures. After the survey, volar locking plates were applied to 30 cadaveric distal radiuses. We intentionally penetrated a single screw into the radiocarpal joint in half of the specimens (15 arms) and intentionally did not penetrate the radiocarpal joint in the other half. Imaging (standard posteroanterior [PA] and lateral views, 11 degrees tilt PA and 22 degrees tilt lateral views, and two 360 degrees fluoroscopy movies) was performed using a custom jig. Five surgeons blinded to results reviewed randomized image sets evaluating for intra-articular screw placement. Receiver operating characteristic curves were constructed to compare the reliability of each fluoroscopic projection or movie.
RESULTS: Among 696 survey respondents, 606 exclusively used fluoroscopic imaging (without cassette radiographs) and over 450 preferred either tilt images or rotational fluoroscopy to detect intra-articular screw penetration. In our cadaveric model, rotational fluoroscopy provided the highest sensitivity (93%) and specificity (96%) for the detection of intra-articular screw penetration. Rotational fluoroscopy was significantly more reliable (p<.01) than most images (standard lateral, 11 degrees PA, 22 degrees lateral, paired PA/lateral) and trended strongly toward better reliability for all remaining images (standard PA [p=.07], paired 11 degrees PA/22 degrees lateral [p=.08], and 22 degrees tilt fluoroscopy movie [p=.11]).
CONCLUSIONS: Rotational fluoroscopy improves the surgeon's ability to detect intra-articular screw penetration during volar plating of the distal radius. No combination of imaging allowed detection of all intra-articular screws. A high level of suspicion for intra-articular screw penetration should be maintained during volar plating of distal radial fractures.

Entities:  

Mesh:

Year:  2010        PMID: 20202762      PMCID: PMC2854080          DOI: 10.1016/j.jhsa.2009.12.033

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  9 in total

1.  Tangential views of the articular surface of the distal radius-aid to open reduction and internal fixation of fractures.

Authors:  D Kumar; L Breakwell; S C Deshmukh; B K Singh
Journal:  Injury       Date:  2001-12       Impact factor: 2.586

2.  Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction--a biomechanic study in a cadaveric model.

Authors:  Herwig Drobetz; Adam L Bryant; Tom Pokorny; Ralf Spitaler; Martin Leixnering; Jesse B Jupiter
Journal:  J Hand Surg Am       Date:  2006-04       Impact factor: 2.230

3.  Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation.

Authors:  Martin I Boyer; Kenneth J Korcek; Richard H Gelberman; Louis A Gilula; Konstantinos Ditsios; Bradley A Evanoff
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

4.  The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures.

Authors:  Dean W Smith; Mark H Henry
Journal:  J Hand Surg Am       Date:  2004-07       Impact factor: 2.230

5.  Normal palmar tilt: is dorsal tilting really normal?

Authors:  F A Mann; S W Kang; L A Gilula
Journal:  J Hand Surg Br       Date:  1992-06

6.  Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study.

Authors:  Maximillian Soong; Christopher Got; Julia Katarincic; Edward Akelman
Journal:  J Hand Surg Am       Date:  2008-12       Impact factor: 2.230

7.  Tilted lateral radiographs in the evaluation of intra-articular distal radius fractures.

Authors:  D W Lundy; S G Quisling; G M Lourie; C M Feiner; R E Lins
Journal:  J Hand Surg Am       Date:  1999-03       Impact factor: 2.230

8.  Arthroscopic assessment of intra-articular distal radius fractures after open reduction and internal fixation from a volar approach.

Authors:  Kevin Lutsky; Martin I Boyer; Jennifer A Steffen; Charles A Goldfarb
Journal:  J Hand Surg Am       Date:  2008-04       Impact factor: 2.230

9.  A normal data base of posteroanterior roentgenographic measurements of the wrist.

Authors:  F A Schuind; R L Linscheid; K N An; E Y Chao
Journal:  J Bone Joint Surg Am       Date:  1992-10       Impact factor: 5.284

  9 in total
  5 in total

1.  Intraoperative evaluation of dorsal screw prominence after polyaxial volar plate fixation of distal radius fractures utilizing the Hoya view: a cadaveric study.

Authors:  Donald Dolce; David Goodwin; Meryl Ludwig; Scott Edwards
Journal:  Hand (N Y)       Date:  2014-12

2.  Improving accuracy and confidence in distal radius volar plate screw placement through supplemental radiography: examining specialty, education, and experience levels.

Authors:  Archit Patel; Maya Deza Culbertson; Philip Lahey; Michael Semenovski; Jack Choueka
Journal:  Hand (N Y)       Date:  2013-09

3.  Medial malleolus screws: out in one view and out.

Authors:  Jeffrey C Wera; David Seligson; John T Riehl
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-22

4.  Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures.

Authors:  Sascha Rausch; Ivan Marintschev; Isabel Graul; Arne Wilharm; Kajetan Klos; Gunther O Hofmann; Marc Florian Gras
Journal:  Arch Trauma Res       Date:  2015-06-20

5.  Volar Locking Plate Fixation for Distal Radius Fractures by Intraoperative Computed Tomographic-Guided Navigation.

Authors:  Akira Kawabata; Yusuke Sogabe; Yukiko Morimoto; Kiyohito Takamatsu
Journal:  J Hand Surg Glob Online       Date:  2020-09-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.