Literature DB >> 10194007

Tilted lateral radiographs in the evaluation of intra-articular distal radius fractures.

D W Lundy1, S G Quisling, G M Lourie, C M Feiner, R E Lins.   

Abstract

The anatomy of the distal radius confounds the assessment of fracture displacement of the lunate facet. Since reduction of the articular surface is paramount to obtaining good clinical results, this study was designed to evaluate whether a radiograph taken 22 degrees from true lateral (forearm held at a 22 degrees angle from the horizontal film cassette) would enhance the accuracy of measuring displacement. Fifteen lunate facet fractures of varying depression were produced in 7 fresh cadaveric wrists. Posteroanterior (PA), standard lateral, and 22 degrees tilted lateral radiographs were obtained of each fracture pattern. Four observers reviewed the films and measured the depression of the fragments from their anatomic position. Measurement error from actual depression averaged 1.1 mm when the evaluators evaluated the 22 degrees lateral and PA films, 1.5 mm for the standard lateral and PA views, and 0.8 mm for the standard lateral, 22 degrees lateral, and PA radiographs (combined group). The decrease in measurement error obtained from all 3 groups was statistically significant. The results of this study suggest that the 22 degrees tilted lateral, either in combination with the standard lateral radiograph or just with the PA view, may help the hand surgeon better understand the intra-articular depression of lunate facet fractures of the distal radius.

Entities:  

Mesh:

Year:  1999        PMID: 10194007     DOI: 10.1053/jhsu.1999.0249

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

1.  Radiographic evaluation of the distal radius using two novel biplanar "pitch-and-roll" views: a preliminary cadaveric study.

Authors:  Brandon M Boyce; Jaiyoung Ryu
Journal:  Hand (N Y)       Date:  2009-04-11

2.  Intraoperative Tilted Posteroanterior View for the Measurement of Distal Radius Articular Step-Off.

Authors:  Steven Beldner; Remy V Rabinovich; Daniel B Polatsch
Journal:  J Wrist Surg       Date:  2019-04-16

3.  Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius.

Authors:  Matthew L Tweet; Ryan P Calfee; Peter J Stern
Journal:  J Hand Surg Am       Date:  2010-03-03       Impact factor: 2.230

4.  WHAT IS THE BEST RADIOGRAPHIC VIEW FOR "DIE PUNCH" DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY.

Authors:  Diego Figueira Falcochio; Bruno Eiras Crepaldi; Christiano Augusto Trindade; Antonio Carlos da Costa; Ivan Chakkour
Journal:  Rev Bras Ortop       Date:  2015-11-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.