Literature DB >> 20195695

Comparison of image enhancement methods for the effective diagnosis in successive whole-body bone scans.

Chang Bu Jeong1, Kwang Gi Kim, Tae Sung Kim, Seok Ki Kim.   

Abstract

Whole-body bone scan is one of the most frequent diagnostic procedures in nuclear medicine. Especially, it plays a significant role in important procedures such as the diagnosis of osseous metastasis and evaluation of osseous tumor response to chemotherapy and radiation therapy. It can also be used to monitor the possibility of any recurrence of the tumor. However, it is a very time-consuming effort for radiologists to quantify subtle interval changes between successive whole-body bone scans because of many variations such as intensity, geometry, and morphology. In this paper, we present the most effective method of image enhancement based on histograms, which may assist radiologists in interpreting successive whole-body bone scans effectively. Forty-eight successive whole-body bone scans from 10 patients were obtained and evaluated using six methods of image enhancement based on histograms: histogram equalization, brightness-preserving bi-histogram equalization, contrast-limited adaptive histogram equalization, end-in search, histogram matching, and exact histogram matching (EHM). Comparison of the results of the different methods was made using three similarity measures peak signal-to-noise ratio, histogram intersection, and structural similarity. Image enhancement of successive bone scans using EHM showed the best results out of the six methods measured for all similarity measures. EHM is the best method of image enhancement based on histograms for diagnosing successive whole-body bone scans. The method for successive whole-body bone scans has the potential to greatly assist radiologists quantify interval changes more accurately and quickly by compensating for the variable nature of intensity information. Consequently, it can improve radiologists' diagnostic accuracy as well as reduce reading time for detecting interval changes.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20195695      PMCID: PMC3092044          DOI: 10.1007/s10278-010-9273-x

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  8 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  Computerized segmentation of whole-body bone scintigrams and its use in automated diagnostics.

Authors:  Luka Sajn; Matjaz Kukar; Igor Kononenko; Metka Milcinski
Journal:  Comput Methods Programs Biomed       Date:  2005-10       Impact factor: 5.428

3.  Exact histogram specification.

Authors:  Dinu Coltuc; Philippe Bolon; Jean-Marc Chassery
Journal:  IEEE Trans Image Process       Date:  2006-05       Impact factor: 10.856

4.  A new computer-based decision-support system for the interpretation of bone scans.

Authors:  May Sadik; David Jakobsson; Fredrik Olofsson; Mattias Ohlsson; Madis Suurkula; Lars Edenbrandt
Journal:  Nucl Med Commun       Date:  2006-05       Impact factor: 1.690

5.  Usefulness of temporal subtraction images for identification of interval changes in successive whole-body bone scans: JAFROC analysis of radiologists' performance.

Authors:  Junji Shiraishi; Daniel Appelbaum; Yonglin Pu; Qiang Li; Lorenzo Pesce; Kunio Doi
Journal:  Acad Radiol       Date:  2007-08       Impact factor: 3.173

Review 6.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

7.  Development of a computer-aided diagnostic scheme for detection of interval changes in successive whole-body bone scans.

Authors:  Junji Shiraishi; Qiang Li; Daniel Appelbaum; Yonglin Pu; Kunio Doi
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

8.  A computer-aided diagnosis for locating abnormalities in bone scintigraphy by a fuzzy system with a three-step minimization approach.

Authors:  Tang-Kai Yin; Nan-Tsing Chiu
Journal:  IEEE Trans Med Imaging       Date:  2004-05       Impact factor: 10.048

  8 in total
  6 in total

1.  Computer-aided quantitative bone scan assessment of prostate cancer treatment response.

Authors:  Matthew S Brown; Gregory H Chu; Hyun J Kim; Martin Allen-Auerbach; Cheryce Poon; Juliette Bridges; Adria Vidovic; Bharath Ramakrishna; Judy Ho; Michael J Morris; Steven M Larson; Howard I Scher; Jonathan G Goldin
Journal:  Nucl Med Commun       Date:  2012-04       Impact factor: 1.690

2.  An automatic fine-grained skeleton segmentation method for whole-body bone scintigraphy using atlas-based registration.

Authors:  Jianan Wei; Huawei Cai; Yong Pi; Zhen Zhao; Zhang Yi
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-03-12       Impact factor: 2.924

3.  New parametric imaging method with fluorescein angiograms for detecting areas of capillary nonperfusion.

Authors:  Young Jae Kim; Chang Bu Jeong; Jeong-Min Hwang; Hee Kyung Yang; Seung Hyun Lee; Kwang Gi Kim
Journal:  Healthc Inform Res       Date:  2014-07-31

4.  Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

Authors:  Anil Kumar Pandey; Param Dev Sharma; Pankaj Dheer; Girish Kumar Parida; Harish Goyal; Chetan Patel; Chandrashekhar Bal; Rakesh Kumar
Journal:  Indian J Nucl Med       Date:  2017 Oct-Dec

5.  Improving technetium-99m methylene diphosphonate bone scan images using histogram specification technique.

Authors:  Anil Kumar Pandey; Param Dev Sharma; Akshima Sharma; Ashish Negi; Girish Kumar Parida; Harish Goyal; Chandra Sekhar Bal; Rakesh Kumar
Journal:  World J Nucl Med       Date:  2020-07-22

6.  Methylene Diphosphonate Bone Scan Scintigraphic Image Enhancement using Gamma Correction and Optimizing the Value of Gamma.

Authors:  Anshul Sharma; Anil Kumar Pandey; Deepak Khichi; Rakesh Kumar
Journal:  Indian J Nucl Med       Date:  2019-12-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.