Literature DB >> 15147016

A computer-aided diagnosis for locating abnormalities in bone scintigraphy by a fuzzy system with a three-step minimization approach.

Tang-Kai Yin1, Nan-Tsing Chiu.   

Abstract

Bone scintigraphy is an effective method to diagnose bone diseases such as bone tumors. In the scintigraphic images, bone abnormalities are widely scattered on the whole body. Conventionally, radiologists visually check the whole-body images and find the distributed abnormalities based on their expertise. This manual process is time-consuming and it is not unusual to miss some abnormalities. In this paper, a computer-aided diagnosis (CAD) system is proposed to assist radiologists in the diagnosis of bone scintigraphy. The system will provide warning marks and abnormal scores on some locations of the images to direct radiologists' attention toward these locations. A fuzzy system called characteristic-point-based fuzzy inference system (CPFIS) is employed to implement the diagnosis system and three minimizations are used to systematically train the CPFIS. Asymmetry and brightness are chosen as the two inputs to the CPFIS according to radiologists' knowledge. The resulting CAD system is of a small-sized rule base such that the resulting fuzzy rules can be not only easily understood by radiologists, but also matched to and compared with their expert knowledge. The prototype CAD system was tested on 82 abnormal images and 27 normal images. We employed free-response receiver operating characteristics method with the mean number of false positives (FPs) and the sensitivity as performance indexes to evaluate the proposed system. The sensitivity is 91.5% (227 of 248) and the mean number of FPs is 37.3 per image. The high sensitivity and moderate numbers of FP marks per image shows that the proposed method can provide an effective second-reader information to radiologists in the diagnosis of bone scintigraphy.

Entities:  

Mesh:

Year:  2004        PMID: 15147016     DOI: 10.1109/tmi.2004.826355

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Reliable evaluation of performance level for computer-aided diagnostic scheme.

Authors:  Qiang Li
Journal:  Acad Radiol       Date:  2007-08       Impact factor: 3.173

Review 2.  A new family of distance functions for perceptual similarity retrieval of medical images.

Authors:  Joaquim Cezar Felipe; Caetano Traina; Agma Juci Machado Traina
Journal:  J Digit Imaging       Date:  2008-01-11       Impact factor: 4.056

3.  Computer-aided quantitative bone scan assessment of prostate cancer treatment response.

Authors:  Matthew S Brown; Gregory H Chu; Hyun J Kim; Martin Allen-Auerbach; Cheryce Poon; Juliette Bridges; Adria Vidovic; Bharath Ramakrishna; Judy Ho; Michael J Morris; Steven M Larson; Howard I Scher; Jonathan G Goldin
Journal:  Nucl Med Commun       Date:  2012-04       Impact factor: 1.690

4.  Comparison of image enhancement methods for the effective diagnosis in successive whole-body bone scans.

Authors:  Chang Bu Jeong; Kwang Gi Kim; Tae Sung Kim; Seok Ki Kim
Journal:  J Digit Imaging       Date:  2011-06       Impact factor: 4.056

5.  Wavelet method for CT colonography computer-aided polyp detection.

Authors:  Jiang Li; Robert Van Uitert; Jianhua Yao; Nicholas Petrick; Marek Franaszek; Adam Huang; Ronald M Summers
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  An automatic fine-grained skeleton segmentation method for whole-body bone scintigraphy using atlas-based registration.

Authors:  Jianan Wei; Huawei Cai; Yong Pi; Zhen Zhao; Zhang Yi
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-03-12       Impact factor: 2.924

Review 7.  Application of SPECT and PET / CT with computer-aided diagnosis in bone metastasis of prostate cancer: a review.

Authors:  Zhao Chen; Xueqi Chen; Rongfu Wang
Journal:  Cancer Imaging       Date:  2022-04-15       Impact factor: 5.605

8.  Automatic vertebral column extraction by whole-body bone SPECT scan.

Authors:  Sheng-Fang Huang; Hao-Yu Chao; Pan-Fu Kao; Wei-Chih Shen; Yu-Hsiang Chou; Shu-Hsin Liu
Journal:  Comput Math Methods Med       Date:  2013-04-10       Impact factor: 2.238