Literature DB >> 20192718

Preclinical analysis of irreversible electroporation on rat liver tissues using a microfabricated electroporator.

Youn-Suk Choi1, Hong-Bae Kim, Junho Chung, Hyung-Sik Kim, Jeong-Han Yi, Je-Kyun Park.   

Abstract

A microfabricated electroporator (MFE) for the irreversible electroporation (IRE) of tissues has been developed by miniaturizing a clinical electroporator with a two-needle array while keeping the same electric field strength distribution. Since IRE was brought to special attention as one of the local tissue ablation techniques to treat tumors, many preclinical studies have been conducted to investigate the efficacy of IRE on animal tissues. However, some technical difficulties have been frequently encountered due to the macroscale dimension of clinical electroporators, particularly in experiments on small animal models such as the mouse or rat. Here, the MFE was proposed to solve the associated problems, resulting in time- and cost-effective experimental procedures. With the developed MFE, the effect of IRE on rat liver tissues was analyzed with time by immunohistological stainings and electrical measurement, and the experimental results were compared with those operated with the corresponding real-scale clinical electroporator.

Entities:  

Mesh:

Year:  2010        PMID: 20192718     DOI: 10.1089/ten.TEC.2009.0803

Source DB:  PubMed          Journal:  Tissue Eng Part C Methods        ISSN: 1937-3384            Impact factor:   3.056


  7 in total

1.  Histological and Mathematical Analysis of the Irreversibly Electroporated Liver Tissue.

Authors:  Chang Kyu Sung; Hong Bae Kim; Jong Hyun Jung; Ku Youn Baik; Kee Wook Moon; Hyung-Sik Kim; Jeong-Han Yi; Jong Hoon Chung
Journal:  Technol Cancer Res Treat       Date:  2016-04-14

2.  Irreversible electroporation: a novel image-guided cancer therapy.

Authors:  Edward W Lee; Susan Thai; Stephen T Kee
Journal:  Gut Liver       Date:  2010-09-10       Impact factor: 4.519

3.  Modification of a Ready-Made High-Voltage Pulse Generator for Non-Thermal Irreversible Electroporation.

Authors:  K Zhang; J Wang
Journal:  Bull Exp Biol Med       Date:  2022-06-23       Impact factor: 0.804

4.  The effects of irreversible electroporation (IRE) on nerves.

Authors:  Wei Li; Qingyu Fan; Zhenwei Ji; Xiuchun Qiu; Zhao Li
Journal:  PLoS One       Date:  2011-04-14       Impact factor: 3.240

Review 5.  Time-Dependent Impact of Irreversible Electroporation on Pancreas, Liver, Blood Vessels and Nerves: A Systematic Review of Experimental Studies.

Authors:  J A Vogel; E van Veldhuisen; P Agnass; J Crezee; F Dijk; J Verheij; T M van Gulik; M R Meijerink; L G Vroomen; K P van Lienden; M G Besselink
Journal:  PLoS One       Date:  2016-11-21       Impact factor: 3.240

6.  Characterization of irreversible electroporation on the stomach: A feasibility study in rats.

Authors:  Jae Min Lee; Hyuk Soon Choi; Eun Sun Kim; Bora Keum; Yeon Seok Seo; Yoon Tae Jeen; Hong Sik Lee; Hoon Jai Chun; Soon Ho Um; Chang Duck Kim; Hong Bae Kim
Journal:  Sci Rep       Date:  2019-06-24       Impact factor: 4.379

7.  Incorporation of Reversible Electroporation Into Electrolysis Accelerates Apoptosis for Rat Liver Tissue.

Authors:  Hong Bae Kim; Jong Hoon Chung
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.