Literature DB >> 20189669

A comparison of two immobilization systems for stereotactic body radiation therapy of lung tumors.

Kathy Han1, Patrick Cheung, Parminder S Basran, Ian Poon, Latifa Yeung, Fiona Lochray.   

Abstract

PURPOSE: This study aims to compare the efficacy, efficiency and comfort level of two immobilization systems commonly used in lung stereotactic body radiation therapy (SBRT): the Bodyfix and the abdominal compression plate (ACP).
MATERIALS AND METHODS: Twenty-four patients undergoing SBRT for medically inoperable stage I lung cancer or pulmonary metastases were entered on this prospective randomized study. All underwent 4DCT simulation with free breathing, the Bodyfix, and the ACP to assess respiratory tumor motion. After CT simulation, patients were randomly assigned to immobilization with either the Bodyfix or the ACP for the actual SBRT treatment. Cone beam CTs (CBCTs) were acquired before and after each treatment to assess intrafraction tumor motion. Setup time and patient comfort were recorded.
RESULTS: There were 16 upper lobe, two middle lobe and seven lower-lobe lesions. Both the Bodyfix and the ACP significantly reduced the superior-inferior (SI) and overall respiratory tumor motion compared to free breathing (4.6 and 4.0 vs 5.3mm; 5.3 and 4.7 vs 6.1mm, respectively, p<0.05). The ACP further reduced the SI and overall respiratory tumor motion compared to the Bodyfix (p<0.05). The mean overall intrafraction tumor motion was 2.3mm with the Bodyfix and 2.0mm with the ACP (p>0.05). The ACP was faster to set up and rated more comfortable by patients than the Bodyfix (p<0.05).
CONCLUSIONS: While there is no significant difference between the Bodyfix and ACP in reducing intrafraction tumor motion, the ACP is more comfortable, faster to set up, and superior to the Bodyfix in reducing SI and overall respiratory tumor motion. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20189669     DOI: 10.1016/j.radonc.2010.01.025

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  21 in total

1.  Influence of different treatment techniques and clinical factors over the intrafraction variation on lung stereotactic body radiotherapy.

Authors:  M Rico; E Martínez; S Pellejero; B Bermejo; P Navarrete; M Barrado; M Campo; F Mañeru; E Villafranca; J Aristu
Journal:  Clin Transl Oncol       Date:  2016-01-12       Impact factor: 3.405

2.  Dosimetric evaluation of abdominal compression as a method to reduce the incidence of radiation-induced pneumonitis in lung SBRT treatment.

Authors:  Vikren Sarkar; Long Huang; Yu-Huei Jessica Huang; Martin W Szegedi; Prema Rassiah-Szegedi; Hui Zhao; Ying J Hitchcock; Kristine E Kokeny; Brian Wang; Bill J Salter
Journal:  J Radiosurg SBRT       Date:  2016

3.  Stereotactic ablative body radiotherapy for non-small-cell lung cancer: setup reproducibility with novel arms-down immobilization.

Authors:  Karen Moore; Claire Paterson; Jonathan Hicks; Stephen Harrow; Mark McJury
Journal:  Br J Radiol       Date:  2016-10-06       Impact factor: 3.039

4.  Incorporating imaging information from deep neural network layers into image guided radiation therapy (IGRT).

Authors:  Wei Zhao; Bin Han; Yong Yang; Mark Buyyounouski; Steven L Hancock; Hilary Bagshaw; Lei Xing
Journal:  Radiother Oncol       Date:  2019-07-11       Impact factor: 6.280

Review 5.  Stereotactic body radiotherapy treatment of extracranial metastases.

Authors:  Joseph K Salama; John P Kirkpatrick; Fang-Fang Yin
Journal:  Nat Rev Clin Oncol       Date:  2012-09-25       Impact factor: 66.675

6.  Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors.

Authors:  Ellen Yorke; Ying Xiong; Qian Han; Pengpeng Zhang; Gikas Mageras; Michael Lovelock; Hai Pham; Jian-Ping Xiong; Karyn A Goodman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-18       Impact factor: 7.038

7.  Investigation of gated cone-beam CT to reduce respiratory motion blurring.

Authors:  Russell E Kincaid; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Abraham J Wu; Gig S Mageras
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

8.  Monitoring tumor motion by real time 2D/3D registration during radiotherapy.

Authors:  Christelle Gendrin; Hugo Furtado; Christoph Weber; Christoph Bloch; Michael Figl; Supriyanto Ardjo Pawiro; Helmar Bergmann; Markus Stock; Gabor Fichtinger; Dietmar Georg; Wolfgang Birkfellner
Journal:  Radiother Oncol       Date:  2011-08-30       Impact factor: 6.280

9.  Comparative analysis of thermoplastic masks versus vacuum cushions in stereotactic body radiotherapy.

Authors:  Arturo Navarro-Martin; Jon Cacicedo; Olwen Leaman; Ismael Sancho; Elvira García; Valentin Navarro; Ferran Guedea
Journal:  Radiat Oncol       Date:  2015-08-20       Impact factor: 3.481

10.  Lung tumor motion reproducibility for five patients who received four-fraction VMAT stereotactic ablative body radiotherapy under constrained breathing conditions: a preliminary study.

Authors:  Keiichi Nakagawa; Akihiro Haga; Katsutake Sasaki; Satoshi Kida; Yoshitaka Masutani; Hideomi Yamashita; Wataru Takahashi; Hiroshi Igaki; Akira Sakumi; Kuni Ohtomo; Kiyoshi Yoda
Journal:  J Radiat Res       Date:  2014-06-25       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.