Karen Moore1, Claire Paterson2, Jonathan Hicks2, Stephen Harrow2, Mark McJury3. 1. 1 Department of Radiotherapy, Beatson West of Scotland Cancer Centre, Glasgow, UK. 2. 2 Department of Clinical Oncology, Beatson West of Scotland Cancer Centre, Glasgow, UK. 3. 3 Radiotherapy Physics Section, Department of Clinical Physics and Bio-engineering, Beatson West of Scotland Cancer Centre, Glasgow, UK.
Abstract
OBJECTIVE: A clinical evaluation of the intrafraction and interfraction setup accuracy of a novel thermoplastic mould immobilization device and patient position in early-stage lung cancer being treated with stereotactic radiotherapy at the Beatson West of Scotland Cancer Centre, Glasgow, UK. METHODS: 35 patients were immobilized in a novel, arms-down position, with a four-point Klarity™ (Klarity Medical Products, Ohio, US) clear thermoplastic mould fixed to a SinMed (CIVCO Medical solutions, lowa, US) head and neck board. A knee support was also used for patient comfort and support. Pre- and post-treatment kilovoltage cone beam CT (CBCT) images were fused with the planning CT scan to determine intra- and interfraction motion. A total of 175 CBCT scans were analysed in the longitudinal, vertical and lateral directions. RESULTS: The mean intrafraction errors were 0.05 ± 0.77 mm (lateral), 0.44 ± 1.2 mm (superior-inferior) and -1.44 ± 1.35 mm (anteroposterior), respectively. Mean composite three-dimensional displacement vector was 2.14 ± 1.2 mm. Interfraction errors were -0.66 ± 2.35 mm (lateral), -0.13 ± 3.11 mm (superior-inferior) and 0.00 ± 2.94 mm (anteroposterior), with three-dimensional vector 4.08 ± 2.73 mm. CONCLUSION: Setup accuracy for lung image-guided stereotactic ablative radiotherapy using a unique immobilization device, where patients have arms by their sides, has been shown to be safe and favourably comparable to other published setup data where more complex and cumbersome devices were utilised. There was no arm toxicity reported and low arm doses. Advances in knowledge: We report on the accuracy of a novel patient immobilization device.
OBJECTIVE: A clinical evaluation of the intrafraction and interfraction setup accuracy of a novel thermoplastic mould immobilization device and patient position in early-stage lung cancer being treated with stereotactic radiotherapy at the Beatson West of Scotland Cancer Centre, Glasgow, UK. METHODS: 35 patients were immobilized in a novel, arms-down position, with a four-point Klarity™ (Klarity Medical Products, Ohio, US) clear thermoplastic mould fixed to a SinMed (CIVCO Medical solutions, lowa, US) head and neck board. A knee support was also used for patient comfort and support. Pre- and post-treatment kilovoltage cone beam CT (CBCT) images were fused with the planning CT scan to determine intra- and interfraction motion. A total of 175 CBCT scans were analysed in the longitudinal, vertical and lateral directions. RESULTS: The mean intrafraction errors were 0.05 ± 0.77 mm (lateral), 0.44 ± 1.2 mm (superior-inferior) and -1.44 ± 1.35 mm (anteroposterior), respectively. Mean composite three-dimensional displacement vector was 2.14 ± 1.2 mm. Interfraction errors were -0.66 ± 2.35 mm (lateral), -0.13 ± 3.11 mm (superior-inferior) and 0.00 ± 2.94 mm (anteroposterior), with three-dimensional vector 4.08 ± 2.73 mm. CONCLUSION: Setup accuracy for lung image-guided stereotactic ablative radiotherapy using a unique immobilization device, where patients have arms by their sides, has been shown to be safe and favourably comparable to other published setup data where more complex and cumbersome devices were utilised. There was no arm toxicity reported and low arm doses. Advances in knowledge: We report on the accuracy of a novel patient immobilization device.
Authors: Winnie Li; Douglas J Moseley; Jean-Pierre Bissonnette; Thomas G Purdie; Andrea Bezjak; David A Jaffray Journal: Med Dosim Date: 2009-10-29 Impact factor: 1.482
Authors: Alonso N Gutiérrez; Sotirios Stathakis; Richard Crownover; Carlos Esquivel; Chengyu Shi; Niko Papanikolaou Journal: Med Dosim Date: 2010-05-01 Impact factor: 1.482
Authors: Frank J Lagerwaard; Naomi E Verstegen; Cornelis J A Haasbeek; Ben J Slotman; Marinus A Paul; Egbert F Smit; Suresh Senan Journal: Int J Radiat Oncol Biol Phys Date: 2011-11-19 Impact factor: 7.038
Authors: Inga S Grills; Geoffrey Hugo; Larry L Kestin; Ana Paula Galerani; K Kenneth Chao; Jennifer Wloch; Di Yan Journal: Int J Radiat Oncol Biol Phys Date: 2007-10-29 Impact factor: 7.038
Authors: Coen W Hurkmans; Johan P Cuijpers; Frank J Lagerwaard; Joachim Widder; Uulke A van der Heide; Danny Schuring; Suresh Senan Journal: Radiat Oncol Date: 2009-01-12 Impact factor: 3.481