Automatic temperature control for MR-guided interstitial ultrasound ablation in liver using a percutaneous applicator: ex vivo and in vivo initial studies.

Eric Delabrousse1, Rares Salomir, Alain Birer, Christian Paquet, François Mithieux, Jean-Yves Chapelon, François Cotton, Cyril Lafon.   

Abstract

Image-guided thermal ablation offers minimally invasive options for treating hepatocellular carcinoma and colorectal metastases in liver. Here, the feasibility and the potential benefit of active temperature control for MR-guided percutaneous ultrasound ablation was investigated in pig liver. An MR-compatible interstitial ultrasound applicator (flat transducer), a positioning system with rotation-translation guiding frame, and an orbital ring holder were developed. Step-by-step rotated elementary lesions were produced, each being formed by directive heating of a flame-shaped volume of tissue. In vivo feasibility of automatic temperature control was investigated on two pigs. Proton Resonance Frequency Shift (PRFS)-based MR thermometry was performed on a 1.5-T clinical scanner, using SENSE acceleration and respiratory gating. MR follow-up of animals and macroscopic analysis were performed at 3 and, respectively, 4 days postprocedure. No sonication-related radiofrequency artifacts were detected on MR images. The temperature controller converged to the target elevation within +/-2 degrees C unless the requested power level exceeded the authorized limit. Large variability of the controller's applied powers from one sonication to another was found both ex vivo and in vivo, indicating highly anisotropic acoustic coupling and/or tissue response to identical beam pattern along different radial directions. The automatic control of the temperature enabled reproducible shape of lesions (15 +/- 2 mm radial depth). (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20187177     DOI: 10.1002/mrm.22328

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Temperature imaging of laser-induced thermotherapy (LITT) by MRI: evaluation of different sequences in phantom.

Authors:  Babak Bazrafshan; Frank Hübner; Parviz Farshid; Renate Hammerstingl; Jijo Paul; Vitali Vogel; Werner Mäntele; Thomas J Vogl
Journal:  Lasers Med Sci       Date:  2013-03-28       Impact factor: 3.161

2.  Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model.

Authors:  Matthew S Adams; Vasant A Salgaonkar; Juan Plata-Camargo; Peter D Jones; Aurea Pascal-Tenorio; Hsin-Yu Chen; Donna M Bouley; Graham Sommer; Kim Butts Pauly; Chris J Diederich
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

3.  Realtime control of multiple-focus phased array heating patterns based on noninvasive ultrasound thermography.

Authors:  Andrew Casper; Dalong Liu; Emad S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  2011-07-14       Impact factor: 4.538

4.  Multiple applicator hepatic ablation with interstitial ultrasound devices: theoretical and experimental investigation.

Authors:  Punit Prakash; Vasant A Salgaonkar; E Clif Burdette; Chris J Diederich
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

Review 5.  Catheter-based ultrasound technology for image-guided thermal therapy: current technology and applications.

Authors:  Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2015-03-23       Impact factor: 3.914

6.  Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.

Authors:  Muhammad Zubair; Matthew S Adams; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2021-08-10       Impact factor: 3.914

7.  Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control.

Authors:  Mohamed A Abbass; Allison-Joy Garbo; Neeraja Mahalingam; Jakob K Killin; T Douglas Mast
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06-14       Impact factor: 2.725

8.  In vivo ultrasound thermal ablation control using echo decorrelation imaging in rabbit liver and VX2 tumor.

Authors:  Mohamed A Abbass; Syed A Ahmad; Neeraja Mahalingam; K Sameer Krothapalli; Jack A Masterson; Marepalli B Rao; Peter G Barthe; T Douglas Mast
Journal:  PLoS One       Date:  2019-12-05       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.