Literature DB >> 20185659

Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives.

Daniel A Reuter1, Cecil Huang, Thomas Edrich, Stanton K Shernan, Holger K Eltzschig.   

Abstract

The ability to monitor cardiac output is one of the important cornerstones of hemodynamic assessment for managing critically ill patients at increased risk for developing cardiac complications, and in particular in patients with preexisting cardiovascular comorbidities. For >30 years, single-bolus thermodilution measurement through a pulmonary artery catheter for assessment of cardiac output has been widely accepted as the "clinical standard" for advanced hemodynamic monitoring. In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution technique, such as the transcardiopulmonary thermodilution and lithium dilution techniques. In this review, not only the underlying technical principles and the unique features but also the limitations of each application of indicator dilution are outlined.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20185659     DOI: 10.1213/ANE.0b013e3181cc885a

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  58 in total

1.  Transpulmonary thermodilution measurements are not affected by continuous veno-venous hemofiltration at high blood pump flow.

Authors:  Nicolas Dufour; Marianne Delville; Jean-Louis Teboul; Laurent Camous; Aude Favier du Noyer; Christian Richard; Xavier Monnet
Journal:  Intensive Care Med       Date:  2012-04-28       Impact factor: 17.440

2.  Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.

Authors:  Youn Joung Cho; Chang-Hoon Koo; Tae Kyong Kim; Deok Man Hong; Yunseok Jeon
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

3.  Transpulmonary Thermodilution Versus Transthoracic Echocardiography for Cardiac Output Measurements in Severely Burned Children.

Authors:  Paul Wurzer; Ludwik K Branski; Marc G Jeschke; Arham Ali; Michael P Kinsky; Fredrick J Bohanon; Gabriel Hundeshagen; William B Norbury; Felicia N Williams; Lars-P Kamolz; Celeste C Finnerty; David N Herndon
Journal:  Shock       Date:  2016-09       Impact factor: 3.454

Review 4.  [Goal-directed hemodynamic therapy: Concepts, indications and risks].

Authors:  S A Haas; B Saugel; C J Trepte; D A Reuter
Journal:  Anaesthesist       Date:  2015-07       Impact factor: 1.041

5.  Dynamic device properties of pulse contour cardiac output during transcatheter aortic valve implantation.

Authors:  Martin Petzoldt; Carsten Riedel; Jan Braeunig; Sebastian Haas; Matthias S Goepfert; Hendrik Treede; Stephan Baldus; Alwin E Goetz; Daniel A Reuter
Journal:  J Clin Monit Comput       Date:  2014-10-30       Impact factor: 2.502

6.  Noninvasive photoacoustic measurement of the composite indicator dilution curve for cardiac output estimation.

Authors:  DongYel Kang; Qiaojian Huang; Youzhi Li
Journal:  Biomed Opt Express       Date:  2015-01-15       Impact factor: 3.732

7.  Cardiac output with modified cardio-impedance against inert gas rebreathing during sub-maximal and maximal cycling exercise in healthy and fit subjects.

Authors:  Alessio Del Torto; Øyvind Skattebo; Jostein Hallén; Carlo Capelli
Journal:  Eur J Appl Physiol       Date:  2018-10-17       Impact factor: 3.078

Review 8.  The pulmonary artery catheter.

Authors:  Jean-Louis Vincent
Journal:  J Clin Monit Comput       Date:  2012-08-12       Impact factor: 2.502

Review 9.  Transoesophageal echocardiography during liver transplantation.

Authors:  Lesley De Pietri; Federico Mocchegiani; Chiara Leuzzi; Roberto Montalti; Marco Vivarelli; Vanni Agnoletti
Journal:  World J Hepatol       Date:  2015-10-18

10.  [Peripartum cardiomyopathy: interdisciplinary challenge].

Authors:  B Löser; S Tank; G Hillebrand; B Goldmann; W Diehl; D Biermann; J Schirmer; D A Reuter
Journal:  Anaesthesist       Date:  2013-05       Impact factor: 1.041

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.