| Literature DB >> 20181916 |
James W Snyder1, Gina K Munier, Charles L Johnson.
Abstract
This study compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay to culture by the use of BBL CHROMagar MRSA for the detection of MRSA in 627 nasal surveillance specimens collected from intensive care unit (ICU) patients. The PCR assay had a sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 96.7%, 70.3%, and 100%, respectively. Nine of 19 false-positive PCR specimens grew methicillin-susceptible S. aureus (MSSA) from broth enrichment culture, of which two demonstrated evidence of mecA gene dropout. Compared to culture by the use of BBL CHROMagar MRSA, the BD GeneOhm MRSA PCR assay demonstrated sensitivity and specificity above 95% for the detection of MRSA nasal colonization and provided shorter turnaround time in generating positive and negative final results.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20181916 PMCID: PMC2849557 DOI: 10.1128/JCM.01326-09
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948