Literature DB >> 20175496

In vivo bioluminescence tomography with a blocking-off finite-difference SP3 method and MRI/CT coregistration.

Alexander D Klose1, Bradley J Beattie, Hamid Dehghani, Lena Vider, Carl Le, Vladimir Ponomarev, Ronald Blasberg.   

Abstract

PURPOSE: Bioluminescence imaging is a research tool for studying gene expression levels in small animal models of human disease. Bioluminescence light, however, is strongly scattered in biological tissue and no direct image of the light-emitting reporter probe's location can be obtained. Therefore, the authors have developed a linear image reconstruction method for bioluminescence tomography (BLT) that recovers the three-dimensional spatial bioluminescent source distribution in small animals.
METHODS: The proposed reconstruction method uses third-order simplified spherical harmonics (SP3) solutions to the equation of radiative transfer for modeling the bioluminescence light propagation in optically nonuniform tissue. The SP3 equations and boundary conditions are solved with a finite-difference (FD) technique on a regular grid. The curved geometry of the animal surface was taken into account with a blocking-off region method for regular grids. Coregistered computed tomography (CT) and magnetic resonance (MR) images provide information regarding the geometry of the skin surface and internal organs. The inverse source problem is defined as an algebraic system of linear equations for the unknown source distribution and is iteratively solved given multiview and multispectral boundary measurements. The average tissue absorption parameters, which are used for the image reconstruction process, were calculated with an evolution strategy (ES) from in vivo measurements using an implanted pointlike source of known location and spectrum. Moreover, anatomical information regarding the location of the internal organs and other tissue structures within the animal's body are provided by coregistered MR images.
RESULTS: First, the authors recovered the wavelength-dependent absorption coefficients (average error of 14%) with the ES under ideal conditions by using a numerical mouse model. Next, they reconstructed the average absorption coefficient of a small animal by using an artificial implanted light source and the validated ES. Last, they conducted two in vivo animal experiments and recovered the spatial location of the implanted light source and the spatial distribution of a bioluminescent reporter system located in the kidneys. The source reconstruction results were coregistered to CT and MR images. They further found that accurate bioluminescence image reconstructions could be obtained when segmenting a voidlike cyst with low-scattering and absorption parameters, whereas inaccurate image reconstructions were obtained when assuming a uniform optical parameter distribution instead. The image reconstructions were completed within 23 min on a 3 GHz Intel processor.
CONCLUSIONS: The authors demonstrated on in vivo examples that the combination of anatomical coregistration, accurate optical tissue properties, multispectral acquisition, and a blocking-off FD-SP3 solution of the radiative transfer model significantly improves the accuracy of the BLT reconstructions.

Entities:  

Mesh:

Year:  2010        PMID: 20175496      PMCID: PMC2803718          DOI: 10.1118/1.3273034

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  34 in total

Review 1.  Molecular imaging and cancer.

Authors:  Ronald G Blasberg
Journal:  Mol Cancer Ther       Date:  2003-03       Impact factor: 6.261

2.  Uniqueness theorems in bioluminescence tomography.

Authors:  Ge Wang; Yi Li; Ming Jiang
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

3.  Multimodality registration without a dedicated multimodality scanner.

Authors:  Bradley J Beattie; Gregor J Förster; Ricardo Govantes; Carl H Le; Valerie A Longo; Pat B Zanzonico; Luc Bidaut; Ronald G Blasberg; Jason A Koutcher
Journal:  Mol Imaging       Date:  2007 Mar-Apr       Impact factor: 4.488

4.  Spectrally resolved bioluminescence optical tomography.

Authors:  Hamid Dehghani; Scott C Davis; Shudong Jiang; Brian W Pogue; Keith D Paulsen; Michael S Patterson
Journal:  Opt Lett       Date:  2006-02-01       Impact factor: 3.776

5.  Iterative reconstruction method for light emitting sources based on the diffusion equation.

Authors:  Nikolai V Slavine; Matthew A Lewis; Edmond Richer; Peter P Antich
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

6.  Transport-theory-based stochastic image reconstruction of bioluminescent sources.

Authors:  Alexander D Klose
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-06       Impact factor: 2.129

Review 7.  The future of cancer imaging.

Authors:  David A Benaron
Journal:  Cancer Metastasis Rev       Date:  2002       Impact factor: 9.264

8.  Rapid and quantitative assessment of cancer treatment response using in vivo bioluminescence imaging.

Authors:  A Rehemtulla; L D Stegman; S J Cardozo; S Gupta; D E Hall; C H Contag; B D Ross
Journal:  Neoplasia       Date:  2000 Nov-Dec       Impact factor: 5.715

9.  Combined magnetic resonance and bioluminescence imaging of live mice.

Authors:  Mathieu Allard; Daniel Côté; Lorinda Davidson; Jun Dazai; R Mark Henkelman
Journal:  J Biomed Opt       Date:  2007 May-Jun       Impact factor: 3.170

10.  Multispectral bioluminescence tomography: methodology and simulation.

Authors:  Alexander X Cong; Ge Wang
Journal:  Int J Biomed Imaging       Date:  2006-02-05
View more
  20 in total

Review 1.  A shift from cell cultures to creatures: in vivo imaging of small animals in experimental regenerative medicine.

Authors:  Anna J Studwell; Darrell N Kotton
Journal:  Mol Ther       Date:  2011-09-27       Impact factor: 11.454

2.  The forward and inverse problem in tissue optics based on the radiative transfer equation: a brief review.

Authors:  Alexander D Klose
Journal:  J Quant Spectrosc Radiat Transf       Date:  2010-07-01       Impact factor: 2.468

3.  Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

Authors:  Yidong Yang; Ken Kang-Hsin Wang; Sohrab Eslami; Iulian I Iordachita; Michael S Patterson; John W Wong
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

4.  Multi-modal molecular diffuse optical tomography system for small animal imaging.

Authors:  James A Guggenheim; Hector R A Basevi; Jon Frampton; Iain B Styles; Hamid Dehghani
Journal:  Meas Sci Technol       Date:  2013       Impact factor: 2.046

5.  Bioluminescence tomography with structural information estimated via statistical mouse atlas registration.

Authors:  Bin Zhang; Wanzhou Yin; Hao Liu; Xu Cao; Hongkai Wang
Journal:  Biomed Opt Express       Date:  2018-07-05       Impact factor: 3.732

6.  A parallel adaptive finite element simplified spherical harmonics approximation solver for frequency domain fluorescence molecular imaging.

Authors:  Yujie Lu; Banghe Zhu; Haiou Shen; John C Rasmussen; Ge Wang; Eva M Sevick-Muraca
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

7.  Systematic study of target localization for bioluminescence tomography guided radiation therapy.

Authors:  Jingjing Yu; Bin Zhang; Iulian I Iordachita; Juvenal Reyes; Zhihao Lu; Malcolm V Brock; Michael S Patterson; John W Wong; Ken Kang-Hsin Wang
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

Review 8.  Standardization of Small Animal Imaging-Current Status and Future Prospects.

Authors:  Julia G Mannheim; Firat Kara; Janine Doorduin; Kerstin Fuchs; Gerald Reischl; Sayuan Liang; Marleen Verhoye; Felix Gremse; Laura Mezzanotte; Marc C Huisman
Journal:  Mol Imaging Biol       Date:  2018-10       Impact factor: 3.488

9.  Bioluminescence Tomography-Guided Radiation Therapy for Preclinical Research.

Authors:  Bin Zhang; Ken Kang-Hsin Wang; Jingjing Yu; Sohrab Eslami; Iulian Iordachita; Juvenal Reyes; Reem Malek; Phuoc T Tran; Michael S Patterson; John W Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-12-14       Impact factor: 7.038

10.  Differentiation of tumor vasculature heterogeneity levels in small animals based on total hemoglobin concentration using magnetic resonance-guided diffuse optical tomography in vivo.

Authors:  Tiffany C Kwong; Mitchell Hsing; Yuting Lin; David Thayer; Mehmet Burcin Unlu; Min-Ying Su; Gultekin Gulsen
Journal:  Appl Opt       Date:  2016-07-20       Impact factor: 1.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.