Literature DB >> 20162723

Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints.

Mathias C Galetz1, Ernst W Fleischmann, Christian H Konrad, Adelheid Schuetz, Uwe Glatzel.   

Abstract

Most total knee replacement joints consist of a metal femoral component made from a cobalt-chromium- molybdenum (CoCrMo)-alloy and a tibial component with an ultrahigh molecular weight polyethylene (UHMWPE) bearing surface. Wear of the UHMWPE remains the primary disadvantage of these implants. The allergic potential ascribed to CoCrMo-alloys is a further concern. Other metallic alloys with and without ceramic coatings are clinically used to avoid these problems. This study compared the mechanical surface properties of an oxidized zirconium alloy with those of cast and wrought CoCrMo and TiAlV6-4. Additionally, the influence of a titanium nitride (TiN)-plasma coating on the surface properties was investigated. The composition of the oxidized zirconium layer was analyzed. Micro- and macrohardness tests as well as adhesion tests were used to reveal material differences in terms of their abrasive wear potential in artificial joints.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20162723     DOI: 10.1002/jbm.b.31581

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  11 in total

1.  In vitro evaluation of frictional force of a novel elastic bendable orthodontic wire.

Authors:  Megumi Takada; Akira Nakajima; Shingo Kuroda; Shinya Horiuchi; Noriyoshi Shimizu; Eiji Tanaka
Journal:  Angle Orthod       Date:  2018-05-25       Impact factor: 2.079

2.  In vivo testing of canine prosthetic femoral components with HA-Ti ladder-type coating on vacuum plasma-sprayed Ti substrate.

Authors:  Xian-Lin Zeng; Jing-Feng Li; Shu-Hua Yang; Qi-Xin Zheng; Zhen-Wei Zou
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-08-01

3.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

4.  Increased inflammatory response is associated with less favorable functional results 5 years after total knee arthroplasty.

Authors:  Jörg Lützner; Franziska Beyer; Cornelia Lützner; Peter Thomas; Burkhard Summer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-02-11       Impact factor: 4.342

5.  Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study.

Authors:  Jörg Lützner; Albrecht Hartmann; Gerd Dinnebier; Petra Spornraft-Ragaller; Christine Hamann; Stephan Kirschner
Journal:  Int Orthop       Date:  2013-07-17       Impact factor: 3.075

Review 6.  An overview of recent advances in designing orthopedic and craniofacial implants.

Authors:  Venkata P Mantripragada; Beata Lecka-Czernik; Nabil A Ebraheim; Ambalangodage C Jayasuriya
Journal:  J Biomed Mater Res A       Date:  2013-06-14       Impact factor: 4.396

7.  Wear performance of inverted non-conforming bearings in anatomic total shoulder arthroplasty.

Authors:  Lorenzo Banci; Alessio Meoli; Martin Hintner; Hans Rudolf Bloch
Journal:  Shoulder Elbow       Date:  2019-02-07

Review 8.  Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature.

Authors:  Ruud P van Hove; Inger N Sierevelt; Barend J van Royen; Peter A Nolte
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

Review 9.  Advances in the surface modification techniques of bone-related implants for last 10 years.

Authors:  Zhi-Ye Qiu; Cen Chen; Xiu-Mei Wang; In-Seop Lee
Journal:  Regen Biomater       Date:  2014-10-20

10.  Aucubin suppresses Titanium particles‑mediated apoptosis of MC3T3‑E1 cells and facilitates osteogenesis by affecting the BMP2/Smads/RunX2 signaling pathway.

Authors:  Ziguan Zhu; Qingping Xie; Yazeng Huang; Shuijun Zhang; Yu Chen
Journal:  Mol Med Rep       Date:  2018-07-16       Impact factor: 2.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.