Literature DB >> 20155342

New device for intraoperative graft assessment: HyperEye charge-coupled device camera system.

Takemi Handa1, Rajesh G Katare, Hideaki Nishimori, Seiichiro Wariishi, Takashi Fukutomi, Masaki Yamamoto, Shiro Sasaguri, Takayuki Sato.   

Abstract

PURPOSE: Our institution developed a new color chargecoupled device (CCD) camera system (HyperEye system) for intraoperative indocyanine green (ICG) angiography. The device consists of a combination of custommade optical filters and an ultra-high-sensitive CCD image sensor with non-Bayer color filter array (i.e., HyperEye technology), which can detect simultaneously color and near-infrared (NIR) rays from 380 to 1200 nm. Here, we demonstrate intraoperative graft assessment using the HyperEye system.
METHODS: We investigated the intraoperative graft patency using both the HyperEye system and transittime flowmetry (TFM) in 51 patients between April 2007 and April 2009 while ICG dye was injected through a central venous catheter. Each patient signed a consent form before the surgery.
RESULTS: We obtained intraoperative graft flows and images in 189 anastomoses of 153 grafts. Both the HyperEye system and TFM indicated the patency of the grafts in 129 grafts. Both the HyperEye system and TFM detected the abnormality of the graft in seven grafts. For the competitive flows, the HyperEye system captured to-and-fro flow fluorescence and TFM detected the retrograde waveform in 16 grafts. On the other hand, although TFM indicated the patency of the graft, the HyperEye system suspected nonoccluded graft failure in seven grafts. In contrast, although TFM detected a mean flow of <10 ml/min, the HyperEye system captured the patent perfusion fluorescence in four grafts.
CONCLUSION: The HyperEye system can visualize any structural and functional failures. Our findings suggest that this device could become a useful tool for intraoperative graft assessment.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20155342     DOI: 10.1007/s11748-009-0536-8

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  18 in total

1.  A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency.

Authors:  Lognathen Balacumaraswami; Yasir Abu-Omar; Bikram Choudhary; David Pigott; David P Taggart
Journal:  J Thorac Cardiovasc Surg       Date:  2005-08       Impact factor: 5.209

2.  SPY: an innovative intra-operative imaging system to evaluate graft patency during off-pump coronary artery bypass grafting.

Authors:  Masao Takahashi; Toshihiro Ishikawa; Koichi Higashidani; Hiroki Katoh
Journal:  Interact Cardiovasc Thorac Surg       Date:  2004-09

Review 3.  Intraoperative imaging techniques to assess coronary artery bypass graft patency.

Authors:  Lognathen Balacumaraswami; David P Taggart
Journal:  Ann Thorac Surg       Date:  2007-06       Impact factor: 4.330

4.  Predictive factors for the intermediate-term patency of arterial grafts in aorta no-touch off-pump coronary revascularization.

Authors:  Hiroyuki Nakajima; Junjiro Kobayashi; Toshihiro Funatsu; Yusuke Shimahara; Masashi Kawamura; Atsushi Kawamura; Toshikatsu Yagihara; Soichiro Kitamura
Journal:  Eur J Cardiothorac Surg       Date:  2007-09-06       Impact factor: 4.191

5.  Factors affecting internal mammary artery graft survival: how is competitive flow from a patent native coronary vessel a risk factor?

Authors:  S Pagni; J Storey; J Ballen; W Montgomery; N K Qaqish; S Etoch; P A Spence
Journal:  J Surg Res       Date:  1997-08       Impact factor: 2.192

6.  A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts.

Authors:  Nimesh D Desai; Senri Miwa; David Kodama; Taadaki Koyama; Gideon Cohen; Marc P Pelletier; Eric A Cohen; George T Christakis; Bernard S Goldman; Stephen E Fremes
Journal:  J Thorac Cardiovasc Surg       Date:  2006-07-28       Impact factor: 5.209

7.  Early angiographic control of perioperative ischemia after coronary artery bypass grafting.

Authors:  A M Fabricius; W Gerber; M Hanke; J Garbade; R Autschbach; F W Mohr
Journal:  Eur J Cardiothorac Surg       Date:  2001-06       Impact factor: 4.191

8.  ITA versus SVG: a comparison of instantaneous pressure and flow dynamics during competitive flow.

Authors:  S Pagni; J Storey; J Ballen; W Montgomery; B Y Chiang; S Etoch; P A Spence
Journal:  Eur J Cardiothorac Surg       Date:  1997-06       Impact factor: 4.191

9.  Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization.

Authors:  David P Taggart; Bikram Choudhary; Kyriakos Anastasiadis; Yasir Abu-Omar; Lognathen Balacumaraswami; David W Pigott
Journal:  Ann Thorac Surg       Date:  2003-03       Impact factor: 4.330

10.  A new and simplified method for coronary and graft imaging during CABG.

Authors:  Fraser D Rubens; Marc Ruel; Stephen E Fremes
Journal:  Heart Surg Forum       Date:  2002       Impact factor: 0.676

View more
  22 in total

Review 1.  The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery.

Authors:  Boudewijn E Schaafsma; J Sven D Mieog; Merlijn Hutteman; Joost R van der Vorst; Peter J K Kuppen; Clemens W G M Löwik; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer
Journal:  J Surg Oncol       Date:  2011-04-14       Impact factor: 3.454

2.  Successful treatment of non-occlusive mesenteric ischemia with indocyanine green fluorescence and open-abdomen management.

Authors:  Toshiyuki Irie; Takeshi Matsutani; Nobutoshi Hagiwara; Tsutomu Nomura; Itsuo Fujita; Yoshikazu Kanazawa; Daisuke Kakinuma; Eiji Uchida
Journal:  Clin J Gastroenterol       Date:  2017-09-27

3.  Reconstruction using a divided latissimus dorsi muscle flap after conventional posterolateral thoracotomy and the effectiveness of indocyanine green-fluorescence angiography to assess intraoperative blood flow.

Authors:  Motone Kuriyama; Akiko Yano; Yukitaka Yoshida; Maiko Kubo; Shinsuke Akita; Nobuyuki Mitsukawa; Kaneshige Satoh; Shin Yamamoto; Shiro Sasaguri; Kazumasa Orihashi
Journal:  Surg Today       Date:  2015-05-05       Impact factor: 2.549

4.  Efficacy of intraoperative HyperEye Medical System angiography for coronary artery bypass grafting.

Authors:  Masaki Yamamoto; Kazumasa Orihashi; Hideaki Nishimori; Takemi Handa; Nobuo Kondo; Takashi Fukutomi; Takayuki Sato
Journal:  Surg Today       Date:  2014-08-28       Impact factor: 2.549

Review 5.  Recent advances in near-infrared fluorescence-guided imaging surgery using indocyanine green.

Authors:  Tsutomu Namikawa; Takayuki Sato; Kazuhiro Hanazaki
Journal:  Surg Today       Date:  2015-03-29       Impact factor: 2.549

Review 6.  Assessing intraoperative blood flow in cardiovascular surgery.

Authors:  Masaki Yamamoto; Shiro Sasaguri; Takayuki Sato
Journal:  Surg Today       Date:  2011-10-04       Impact factor: 2.549

7.  Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy?

Authors:  Tyler R McClintock; Marc A Bjurlin; James S Wysock; Michael S Borofsky; Tracy P Marien; Chinonyerem Okoro; Michael D Stifelman
Journal:  Urology       Date:  2014-06-06       Impact factor: 2.649

Review 8.  Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging.

Authors:  Alisha V DSouza; Huiyun Lin; Eric R Henderson; Kimberley S Samkoe; Brian W Pogue
Journal:  J Biomed Opt       Date:  2016-08-01       Impact factor: 3.170

9.  Oncoplastic surgery combining partial mastectomy and immediate volume replacement using a thoracodorsal adipofascial cutaneous flap with a crescent-shaped dermis.

Authors:  Yuko Kijima; Heiji Yoshinaka; Munetsugu Hirata; Hideo Arima; Akihiro Nakajo; Yoshiaki Shinden; Yoshikazu Uenosono; Hiroshi Okumura; Sumiya Ishigami; Shoji Natsugoe
Journal:  Surg Today       Date:  2013-12-22       Impact factor: 2.549

10.  Maximal blood flow acceleration analysis in the early diastolic phase for aortocoronary artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting.

Authors:  Takemi Handa; Kazumasa Orihashi; Hideaki Nishimori; Masaki Yamamoto
Journal:  Surg Today       Date:  2016-03-19       Impact factor: 2.549

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.