Literature DB >> 17670291

SPY: an innovative intra-operative imaging system to evaluate graft patency during off-pump coronary artery bypass grafting.

Masao Takahashi1, Toshihiro Ishikawa, Koichi Higashidani, Hiroki Katoh.   

Abstract

Off-pump coronary artery bypass grafting (CABG) has been rapidly increased, because of its less invasiveness with low complications. However, graft patency rate highly depends on the operators' capability due to technical difficulties. The SPY system, based on the fluorescence of indocyanine green, is an innovative device that permits validation of graft patency intra-operatively. Real time images of grafts are obtained with no need for catheterization, X-rays or iodine contrast medium. High-quality images could be obtained in all 290 grafts of 72 off-pump CABG cases (mean 4.0 grafts per patient). Four anastomoses (1.4%), including two proximal and two distal, were revised because of defects detected by SPY images. In one case, the SPY system revealed no blood flow in a radial sequential graft, although transit-time flow meter measurements showed a diastolic dominant pattern. SPY images provide critical information to surgeons to detect non-patent grafts, allowing them to be revised while the patient is still on the operating table. Using the SPY system, technical failures could be completely resolved during surgery. The use of the SPY system for intra-operative graft validation during off-pump CABG may become the gold standard for surgical management in the near future.

Entities:  

Year:  2004        PMID: 17670291     DOI: 10.1016/j.icvts.2004.01.018

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  12 in total

1.  Image overlay solution based on threshold detection for a compact near infrared fluorescence goggle system.

Authors:  Shengkui Gao; Suman B Mondal; Nan Zhu; RongGuang Liang; Samuel Achilefu; Viktor Gruev
Journal:  J Biomed Opt       Date:  2015-01       Impact factor: 3.170

Review 2.  Intraoperative graft assessment during coronary artery bypass surgery.

Authors:  Toshihiro Fukui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-01-06

Review 3.  Techniques for intraoperative graft assessment in coronary artery bypass surgery.

Authors:  Lucas B Ohmes; Antonino Di Franco; Gabriele Di Giammarco; Carlo Maria Rosati; Christopher Lau; Leonard N Girardi; Massimo Massetti; Mario Gaudino
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

Review 4.  Assessing intraoperative blood flow in cardiovascular surgery.

Authors:  Masaki Yamamoto; Shiro Sasaguri; Takayuki Sato
Journal:  Surg Today       Date:  2011-10-04       Impact factor: 2.549

5.  New device for intraoperative graft assessment: HyperEye charge-coupled device camera system.

Authors:  Takemi Handa; Rajesh G Katare; Hideaki Nishimori; Seiichiro Wariishi; Takashi Fukutomi; Masaki Yamamoto; Shiro Sasaguri; Takayuki Sato
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-02-13

6.  Intraoperative indocyanine green fluorescence angiography to predict wound complications in complex ventral hernia repair.

Authors:  P D Colavita; B A Wormer; I Belyansky; A Lincourt; S B Getz; B T Heniford; V A Augenstein
Journal:  Hernia       Date:  2015-08-18       Impact factor: 4.739

7.  Maximal blood flow acceleration analysis in the early diastolic phase for aortocoronary artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting.

Authors:  Takemi Handa; Kazumasa Orihashi; Hideaki Nishimori; Masaki Yamamoto
Journal:  Surg Today       Date:  2016-03-19       Impact factor: 2.549

Review 8.  Real-time fluorescence image-guided oncologic surgery.

Authors:  Suman B Mondal; Shengkui Gao; Nan Zhu; Rongguang Liang; Viktor Gruev; Samuel Achilefu
Journal:  Adv Cancer Res       Date:  2014       Impact factor: 6.242

9.  Surgical ligation level of the bronchial artery influences tissue oxygen saturation of the bronchus and the incidence of postoperative bronchofistula after pulmonary lobectomy.

Authors:  Marino Yamamoto; Takashi Anayama; Hironobu Okada; Ryohei Miyazaki; Kazumasa Orihashi
Journal:  Quant Imaging Med Surg       Date:  2021-07

10.  A review of indocyanine green fluorescent imaging in surgery.

Authors:  Jarmo T Alander; Ilkka Kaartinen; Aki Laakso; Tommi Pätilä; Thomas Spillmann; Valery V Tuchin; Maarit Venermo; Petri Välisuo
Journal:  Int J Biomed Imaging       Date:  2012-04-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.