Literature DB >> 16935114

A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts.

Nimesh D Desai1, Senri Miwa, David Kodama, Taadaki Koyama, Gideon Cohen, Marc P Pelletier, Eric A Cohen, George T Christakis, Bernard S Goldman, Stephen E Fremes.   

Abstract

BACKGROUND: Early coronary bypass graft failures may be preventable if identified intraoperatively. The purpose of this investigation was to compare the diagnostic accuracy of two intraoperative graft assessment techniques, transit-time ultrasound flow measurement and indocyanine green fluorescent-dye graft angiography.
METHODS: Patents undergoing isolated coronary artery bypass grafting with no contraindications for postoperative angiography were enrolled in the study. Patients were randomly assigned to be evaluated with either indocyanine green angiography (Novadaq Spy angiography system; Novadaq Technologies Inc, Concord, Ontario, Canada) and then transit-time ultrasonic flow measurement (Medtronic Medi-Stim Butterfly Flowmeter TTF measurement system; Medtronic Inc, Minneapolis, Minn) or transit-time flow then indocyanine green angiography. Patients underwent x-ray angiography on postoperative day 4. The primary end point of the trial was to determine the sensitivity and specificity of the two techniques versus reference standard x-ray angiography to detect graft occlusion or greater than 50% stenosis in the graft or perianastomotic area.
RESULTS: Between February 2004 and March 2005, 106 patients were enrolled and x-ray angiography was performed in 46 patients. In total, 139 grafts were reviewed with all three techniques and 12 grafts (8.2%) were demonstrated to have greater than 50% stenosis or occlusion by the reference standard. The sensitivity and specificity of indocyanine green angiography to detect greater than 50% stenosis or occlusion was 83.3% and 100%, respectively. The sensitivity and specificity of transit-time ultrasonic flow measurement to detect greater than 50% stenosis or occlusion was 25% and 98.4%, respectively. The P value for the overall comparison of sensitivity and specificity between indocyanine green angiography and transit-time flow ultrasonography was .011. The difference between sensitivity for indocyanine green angiography and transit-time flow measurement was 58% with a 95% confidence interval of 30% to 86%, P = .023.
CONCLUSION: Indocyanine green angiography provides better diagnostic accuracy for detecting clinically significant graft errors than does transit-time ultrasound flow measurement.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16935114     DOI: 10.1016/j.jtcvs.2005.09.061

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  36 in total

Review 1.  Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.

Authors:  Sylvain Gioux; Hak Soo Choi; John V Frangioni
Journal:  Mol Imaging       Date:  2010-10       Impact factor: 4.488

Review 2.  The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery.

Authors:  Boudewijn E Schaafsma; J Sven D Mieog; Merlijn Hutteman; Joost R van der Vorst; Peter J K Kuppen; Clemens W G M Löwik; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer
Journal:  J Surg Oncol       Date:  2011-04-14       Impact factor: 3.454

3.  Quantitative assessment technique of HyperEye medical system angiography for coronary artery bypass grafting.

Authors:  Masaki Yamamoto; Hideaki Nishimori; Takemi Handa; Takashi Fukutomi; Kazuki Kihara; Miwa Tashiro; Takayuki Sato; Kazumasa Orihashi
Journal:  Surg Today       Date:  2016-06-28       Impact factor: 2.549

Review 4.  Advances in fluorescence imaging of the cardiovascular system.

Authors:  Kiyuk Chang; Farouc Jaffer
Journal:  J Nucl Cardiol       Date:  2008 May-Jun       Impact factor: 5.952

5.  Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency.

Authors:  Atsutoshi Hatada; Yoshitaka Okamura; Masahiro Kaneko; Takahiro Hisaoka; Shuji Yamamoto; Takeshi Hiramatsu; Yoshiharu Nishimura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-01-12

6.  A novel endoscopic fluorescent clip visible with near-infrared imaging during laparoscopic surgery in a porcine model.

Authors:  Hiroshi Takeyama; Taishi Hata; Junichi Nishimura; Ryoji Nonaka; Mamoru Uemura; Naotsugu Haraguchi; Ichiro Takemasa; Tsunekazu Mizushima; Hirofumi Yamamoto; Yuichiro Doki; Masaki Mori
Journal:  Surg Endosc       Date:  2014-02-25       Impact factor: 4.584

Review 7.  Intraoperative graft assessment during coronary artery bypass surgery.

Authors:  Toshihiro Fukui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-01-06

8.  The use of intraoperative graft assessment in guiding graft revision.

Authors:  Teresa M Kieser; David P Taggart
Journal:  Ann Cardiothorac Surg       Date:  2018-09

9.  Qualitative angiographic and quantitative myocardial perfusion assessment using fluorescent cardiac imaging during graded coronary artery bypass stenosis.

Authors:  Christian Detter; Detlef Russ; Jan Felix Kersten; Hermann Reichenspurner; Sabine Wipper
Journal:  Int J Cardiovasc Imaging       Date:  2017-07-15       Impact factor: 2.357

10.  Intraoperative indocyanine green fluorescence angiography to predict wound complications in complex ventral hernia repair.

Authors:  P D Colavita; B A Wormer; I Belyansky; A Lincourt; S B Getz; B T Heniford; V A Augenstein
Journal:  Hernia       Date:  2015-08-18       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.