The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties.

Cheol-Min Han1, Eun-Jung Lee, Hyoun-Ee Kim, Young-Hag Koh, Keung N Kim, Yoon Ha, Sung-Uk Kuh.   

Abstract

The surface of polyetheretherketone (PEEK) was coated with a pure titanium (Ti) layer using an electron beam (e-beam) deposition method in order to enhance its biocompatibility and adhesion to bone tissue. The e-beam deposition method was a low-temperature coating process that formed a dense, uniform and well crystallized Ti layer without deteriorating the characteristics of the PEEK implant. The Ti coating layer strongly adhered to the substrate and remarkably enhanced its wettability. The Ti-coated samples were evaluated in terms of their in vitro cellular behaviors and in vivo osteointegration, and the results were compared to a pure PEEK substrate. The level of proliferation of the cells (MC3T3-E1) was measured using a methoxyphenyl tetrazolium salt (MTS) assay and more than doubled after the Ti coating. The differentiation level of cells was measured using the alkaline phosphatase (ALP) assay and also doubled. Furthermore, the in vivo animal tests showed that the Ti-coated PEEK implants had a much higher bone-in-contact (BIC) ratio than the pure PEEK implants. These in vitro and in vivo results suggested that the e-beam deposited Ti coating significantly improved the potential of PEEK for hard tissue applications. Copyright 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20153890     DOI: 10.1016/j.biomaterials.2009.12.030

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  36 in total

Review 1.  Radiological and clinical outcomes of novel Ti/PEEK combined spinal fusion cages: a systematic review and preclinical evaluation.

Authors:  Yusuf Assem; Ralph J Mobbs; Matthew H Pelletier; Kevin Phan; William R Walsh
Journal:  Eur Spine J       Date:  2015-12-15       Impact factor: 3.134

2.  Evolution of Design of Interbody Cages for Anterior Lumbar Interbody Fusion.

Authors:  Kevin Phan; Ralph J Mobbs
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

3.  Biocompatibility of polyetheretherketone for the treatment of orbital bone defects.

Authors:  Rui-Dong Gu; Fan Xiao; Lin Wang; Kai-Jian Sun; Lin-Lin Chen
Journal:  Int J Ophthalmol       Date:  2020-05-18       Impact factor: 1.779

4.  Getting PEEK to Stick to Bone: The Development of Porous PEEK for Interbody Fusion Devices.

Authors:  F Brennan Torstrick; David L Safranski; J Kenneth Burkus; James L Chappuis; Christopher S D Lee; Robert E Guldberg; Ken Gall; Kathryn E Smith
Journal:  Tech Orthop       Date:  2017-09-01

5.  Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?

Authors:  F Brennan Torstrick; Nathan T Evans; Hazel Y Stevens; Ken Gall; Robert E Guldberg
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

6.  High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants.

Authors:  Nathan T Evans; F Brennan Torstrick; Christopher S D Lee; Kenneth M Dupont; David L Safranski; W Allen Chang; Annie E Macedo; Angela S P Lin; Jennifer M Boothby; Daniel C Whittingslow; Robert A Carson; Robert E Guldberg; Ken Gall
Journal:  Acta Biomater       Date:  2014-11-24       Impact factor: 8.947

7.  Rough titanium alloys regulate osteoblast production of angiogenic factors.

Authors:  Rene Olivares-Navarrete; Sharon L Hyzy; Rolando A Gittens; Jennifer M Schneider; David A Haithcock; Peter F Ullrich; Paul J Slosar; Zvi Schwartz; Barbara D Boyan
Journal:  Spine J       Date:  2013-05-14       Impact factor: 4.166

Review 8.  Polyetheretherketone (PEEK) for medical applications.

Authors:  Ivan Vladislavov Panayotov; Valérie Orti; Frédéric Cuisinier; Jacques Yachouh
Journal:  J Mater Sci Mater Med       Date:  2016-06-03       Impact factor: 3.896

9.  Surface topography and wetting modifications of PEEK for implant applications.

Authors:  Cagri Kaan Akkan; Mohammed Eid Hammadeh; Alexander May; Hai-Woong Park; Hashim Abdul-Khaliq; Thomas Strunskus; Oral Cenk Aktas
Journal:  Lasers Med Sci       Date:  2014-04-02       Impact factor: 3.161

10.  Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle.

Authors:  R Guillot; I Pignot-Paintrand; J Lavaud; A Decambron; E Bourgeois; V Josserand; D Logeart-Avramoglou; E Viguier; C Picart
Journal:  Acta Biomater       Date:  2016-03-07       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.