Literature DB >> 20152793

Empirically optimized flow cytometric immunoassay validates ambient analyte theory.

Zaheer A Parpia1, David M Kelso.   

Abstract

Ekins' ambient analyte theory predicts, counterintuitively, that an immunoassay's limit of detection can be improved by reducing the amount of capture antibody. In addition, it also anticipates that results should be insensitive to the volume of sample as well as the amount of capture antibody added. The objective of this study was to empirically validate all of the performance characteristics predicted by Ekins' theory. Flow cytometric analysis was used to detect binding between a fluorescent ligand and capture microparticles because it can directly measure fractional occupancy, the primary response variable in ambient analyte theory. After experimentally determining ambient analyte conditions, comparisons were carried out between ambient and nonambient assays in terms of their signal strengths, limits of detection, and sensitivity to variations in reaction volume and number of particles. The critical number of binding sites required for an assay to be in the ambient analyte region was estimated to be 0.1 VK(d). As predicted, such assays exhibited superior signal/noise levels and limits of detection and were not affected by variations in sample volume and number of binding sites. When the signal detected measures fractional occupancy, ambient analyte theory is an excellent guide to developing assays with superior performance characteristics. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20152793      PMCID: PMC2874886          DOI: 10.1016/j.ab.2009.03.050

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  13 in total

1.  Suspension array technology: evolution of the flat-array paradigm.

Authors:  John P Nolan; Larry A Sklar
Journal:  Trends Biotechnol       Date:  2002-01       Impact factor: 19.536

2.  Evaluating sandwich immunoassays in microarray format in terms of the ambient analyte regime.

Authors:  Petri Saviranta; Ryan Okon; Achim Brinker; Masaki Warashina; Joerg Eppinger; Bernhard H Geierstanger
Journal:  Clin Chem       Date:  2004-08-12       Impact factor: 8.327

3.  Multispot, multianalyte, immunoassay.

Authors:  R Ekins; F Chu; E Biggart
Journal:  Ann Biol Clin (Paris)       Date:  1990       Impact factor: 0.459

4.  Array feature size influences nucleic acid surface capture in DNA microarrays.

Authors:  David S Dandy; Peng Wu; David W Grainger
Journal:  Proc Natl Acad Sci U S A       Date:  2007-05-07       Impact factor: 11.205

Review 5.  Multianalyte microspot immunoassay--microanalytical "compact disk" of the future.

Authors:  R P Ekins; F W Chu
Journal:  Clin Chem       Date:  1991-11       Impact factor: 8.327

Review 6.  Kinetics of antigen-antibody reactions at solid-liquid interfaces.

Authors:  M Stenberg; H Nygren
Journal:  J Immunol Methods       Date:  1988-10-04       Impact factor: 2.303

Review 7.  Diffusion-controlled macromolecular interactions.

Authors:  O G Berg; P H von Hippel
Journal:  Annu Rev Biophys Biophys Chem       Date:  1985

8.  Analysis of ligand-receptor interactions with the fluorescence activated cell sorter.

Authors:  L A Sklar; D A Finney
Journal:  Cytometry       Date:  1982-11

9.  Real-time measurements of DNA hybridization on microparticles with fluorescence resonance energy transfer.

Authors:  M R Henry; P Wilkins Stevens; J Sun; D M Kelso
Journal:  Anal Biochem       Date:  1999-12-15       Impact factor: 3.365

10.  Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins.

Authors:  Jwa-Min Nam; C Shad Thaxton; Chad A Mirkin
Journal:  Science       Date:  2003-09-26       Impact factor: 47.728

View more
  4 in total

1.  Multiplex IP-FCM (immunoprecipitation-flow cytometry): Principles and guidelines for assessing physiologic protein-protein interactions in multiprotein complexes.

Authors:  Anya T Bida; Diana Gil; Adam G Schrum
Journal:  Methods       Date:  2011-09-16       Impact factor: 3.608

2.  Functionalized Polymer Microgel Particles Enable Customizable Production of Label-Free Sensor Arrays.

Authors:  Mark A Lifson; Jared A Carter; Benjamin L Miller
Journal:  Anal Chem       Date:  2015-07-15       Impact factor: 6.986

3.  Enhancing the detection limit of nanoscale biosensors via topographically selective functionalization.

Authors:  Mark A Lifson; Dhrubajyoti Basu Roy; Benjamin L Miller
Journal:  Anal Chem       Date:  2013-12-27       Impact factor: 6.986

4.  Simultaneous capture and sequential detection of two malarial biomarkers on magnetic microparticles.

Authors:  Christine F Markwalter; Keersten M Ricks; Anna L Bitting; Lwiindi Mudenda; David W Wright
Journal:  Talanta       Date:  2016-08-30       Impact factor: 6.057

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.