Literature DB >> 20150265

Arterial wall dosimetry for non-Hodgkin lymphoma patients treated with radioimmunotherapy.

Robert F Hobbs1, Sébastien Baechler, Richard L Wahl, Bin He, Hong Song, Caroline E Esaias, Eric C Frey, Heather Jacene, George Sgouros.   

Abstract

UNLABELLED: Tumors in non-Hodgkin lymphoma (NHL) patients are often proximal to the major blood vessels in the abdomen or neck. In external-beam radiotherapy, these tumors present a challenge because imaging resolution prevents the beam from being targeted to the tumor lesion without also irradiating the artery wall. This problem has led to potentially life-threatening delayed toxicity. Because radioimmunotherapy has resulted in long-term survival of NHL patients, we investigated whether the absorbed dose (AD) to the artery wall in radioimmunotherapy of NHL is of potential concern for delayed toxicity. SPECT resolution is not sufficient to enable dosimetric analysis of anatomic features of the thickness of the aortic wall. Therefore, we present a model of aortic wall toxicity based on data from 4 patients treated with (131)I-tositumomab.
METHODS: Four NHL patients with periaortic tumors were administered pretherapeutic (131)I-tositumomab. Abdominal SPECT and whole-body planar images were obtained at 48, 72, and 144 h after tracer administration. Blood-pool activity concentrations were obtained from regions of interest drawn on the heart on the planar images. Tumor and blood activity concentrations, scaled to therapeutic administered activities-both standard and myeloablative-were input into a geometry and tracking model (GEANT, version 4) of the aorta. The simulated energy deposited in the arterial walls was collected and fitted, and the AD and biologic effective dose values to the aortic wall and tumors were obtained for standard therapeutic and hypothetical myeloablative administered activities.
RESULTS: Arterial wall ADs from standard therapy were lower (0.6-3.7 Gy) than those typical from external-beam therapy, as were the tumor ADs (1.4-10.5 Gy). The ratios of tumor AD to arterial wall AD were greater for radioimmunotherapy by a factor of 1.9-4.0. For myeloablative therapy, artery wall ADs were in general less than those typical for external-beam therapy (9.4-11.4 Gy for 3 of 4 patients) but comparable for 1 patient (32.6 Gy).
CONCLUSION: Blood vessel radiation dose can be estimated using the software package 3D-RD combined with GEANT modeling. The dosimetry analysis suggested that arterial wall toxicity is highly unlikely in standard dose radioimmunotherapy but should be considered a potential concern and limiting factor in myeloablative therapy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20150265      PMCID: PMC2967028          DOI: 10.2967/jnumed.109.069575

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  38 in total

1.  Renal radiation-induced arterial stenosis.

Authors:  H Izzedine; P Cluzel; G Deray
Journal:  Kidney Int       Date:  2007-06       Impact factor: 10.612

2.  The radiobiology of intravascular irradiation.

Authors:  D J Brenner; R C Miller; E J Hall
Journal:  Int J Radiat Oncol Biol Phys       Date:  1996-11-01       Impact factor: 7.038

Review 3.  The linear-quadratic formula and progress in fractionated radiotherapy.

Authors:  J F Fowler
Journal:  Br J Radiol       Date:  1989-08       Impact factor: 3.039

4.  Radiation dosimetry results and safety correlations from 90Y-ibritumomab tiuxetan radioimmunotherapy for relapsed or refractory non-Hodgkin's lymphoma: combined data from 4 clinical trials.

Authors:  Gregory A Wiseman; Ellen Kornmehl; Bryan Leigh; William D Erwin; Donald A Podoloff; Stewart Spies; Richard B Sparks; Michael G Stabin; Thomas Witzig; Christine A White
Journal:  J Nucl Med       Date:  2003-03       Impact factor: 10.057

5.  Patient-specific dosimetry in predicting renal toxicity with (90)Y-DOTATOC: relevance of kidney volume and dose rate in finding a dose-effect relationship.

Authors:  Raffaella Barone; Françoise Borson-Chazot; Roelf Valkema; Stéphan Walrand; Franck Chauvin; Lida Gogou; Larry K Kvols; Eric P Krenning; François Jamar; Stanislas Pauwels
Journal:  J Nucl Med       Date:  2005-01       Impact factor: 10.057

6.  Randomized controlled trial of yttrium-90-labeled ibritumomab tiuxetan radioimmunotherapy versus rituximab immunotherapy for patients with relapsed or refractory low-grade, follicular, or transformed B-cell non-Hodgkin's lymphoma.

Authors:  Thomas E Witzig; Leo I Gordon; Fernando Cabanillas; Myron S Czuczman; Christos Emmanouilides; Robin Joyce; Brad L Pohlman; Nancy L Bartlett; Gregory A Wiseman; Norman Padre; Antonio J Grillo-López; Pratik Multani; Christine A White
Journal:  J Clin Oncol       Date:  2002-05-15       Impact factor: 44.544

7.  High-dose [131I]tositumomab (anti-CD20) radioimmunotherapy and autologous hematopoietic stem-cell transplantation for adults > or = 60 years old with relapsed or refractory B-cell lymphoma.

Authors:  Ajay K Gopal; Joseph G Rajendran; Ted A Gooley; John M Pagel; Darrell R Fisher; Stephen H Petersdorf; David G Maloney; Janet F Eary; Frederick R Appelbaum; Oliver W Press
Journal:  J Clin Oncol       Date:  2007-02-20       Impact factor: 44.544

8.  MIRD pamphlet No. 20: the effect of model assumptions on kidney dosimetry and response--implications for radionuclide therapy.

Authors:  Barry W Wessels; Mark W Konijnenberg; Roger G Dale; Hazel B Breitz; Marta Cremonesi; Ruby F Meredith; Alan J Green; Lionel G Bouchet; A Bertrand Brill; Wesley E Bolch; George Sgouros; Stephen R Thomas
Journal:  J Nucl Med       Date:  2008-10-16       Impact factor: 10.057

Review 9.  Adult life after surviving lymphoma in childhood.

Authors:  Nicolas X von der Weid
Journal:  Support Care Cancer       Date:  2008-01-15       Impact factor: 3.603

10.  Three-dimensional radiobiologic dosimetry: application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry.

Authors:  Andrew R Prideaux; Hong Song; Robert F Hobbs; Bin He; Eric C Frey; Paul W Ladenson; Richard L Wahl; George Sgouros
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

View more
  9 in total

1.  A model of cellular dosimetry for macroscopic tumors in radiopharmaceutical therapy.

Authors:  Robert F Hobbs; Sébastien Baechler; De-Xue Fu; Caroline Esaias; Martin G Pomper; Richard F Ambinder; George Sgouros
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

2.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

3.  Radiopharmaceutical Therapy.

Authors:  George Sgouros
Journal:  Health Phys       Date:  2019-02       Impact factor: 1.316

4.  A nephron-based model of the kidneys for macro-to-micro α-particle dosimetry.

Authors:  Robert F Hobbs; Hong Song; David L Huso; Margaret H Sundel; George Sgouros
Journal:  Phys Med Biol       Date:  2012-06-15       Impact factor: 3.609

5.  A bone marrow toxicity model for ²²³Ra alpha-emitter radiopharmaceutical therapy.

Authors:  Robert F Hobbs; Hong Song; Christopher J Watchman; Wesley E Bolch; Anne-Kirsti Aksnes; Thomas Ramdahl; Glenn D Flux; George Sgouros
Journal:  Phys Med Biol       Date:  2012-05-01       Impact factor: 3.609

6.  A treatment planning method for sequentially combining radiopharmaceutical therapy and external radiation therapy.

Authors:  Robert F Hobbs; Todd McNutt; Sébastien Baechler; Bin He; Caroline E Esaias; Eric C Frey; David M Loeb; Richard L Wahl; Ori Shokek; George Sgouros
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-10-13       Impact factor: 7.038

7.  Study of the impact of tissue density heterogeneities on 3-dimensional abdominal dosimetry: comparison between dose kernel convolution and direct Monte Carlo methods.

Authors:  Arnaud Dieudonné; Robert F Hobbs; Rachida Lebtahi; Fabien Maurel; Sébastien Baechler; Richard L Wahl; Ariane Boubaker; Dominique Le Guludec; Georges Sgouros; Isabelle Gardin
Journal:  J Nucl Med       Date:  2012-12-18       Impact factor: 10.057

8.  Monte Carlo-based 3-dimensional dosimetry of salivary glands in radioiodine treatment of differentiated thyroid cancer estimated using 124I PET.

Authors:  R F Hobbs; W Jentzen; A Bockisch; G Sgouros
Journal:  Q J Nucl Med Mol Imaging       Date:  2013-03       Impact factor: 2.346

9.  Radiobiologic optimization of combination radiopharmaceutical therapy applied to myeloablative treatment of non-Hodgkin lymphoma.

Authors:  Robert F Hobbs; Richard L Wahl; Eric C Frey; Yvette Kasamon; Hong Song; Peng Huang; Richard J Jones; George Sgouros
Journal:  J Nucl Med       Date:  2013-08-05       Impact factor: 10.057

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.