Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.

Ernest V Garcia1, Russell Folks, Samuel Pak, Andrew Taylor.   

Abstract

INTRODUCTION: An image-processing algorithm (AUTOROI) has been developed to totally automatically (or with manual assistance) detect whole-kidney contours and generate renal regions of interest (ROI) for the extraction of the quantitative measurements used in the interpretation of Tc-mercaptoacetyltriglycine (Tc-MAG3) renograms.
METHODS: The 18-20th min dynamic frames post-MAG3 injection were used to automatically define boxes surrounding each kidney, which were then transposed to an early composite image for interpolative and directional background subtraction. Sobel operator and unsharp masking were applied for edge enhancement, and the resulting image histograms were equalized to better define poorly functioning kidneys. AUTOROI searched radially from the center of mass to define each kidney's ROI coordinates. AUTOROI was validated using MAG3 studies from 79 patients referred for suspected obstruction (79 left, 77 right kidneys) and 19 kidney donors with normal kidney function and no obstruction. Renal ROIs were manually defined by a nuclear medicine technologist with 20+ years of experience (reference standard) and an American Board of Nuclear Medicine certified physician. AUTOROI and physician ROIs were automatically compared with the reference standard to determine the border definition error.
RESULTS: AUTOROI totally automatically detected the renal borders in 89% (172 of 194) of the kidneys from the entire group of 98 patients. The 22 kidneys missed automatically were subsequently detected with the assistance of a single manually placed fiducial point demarcating the liver/kidney boundary. These 22 kidneys were shown to be associated with markedly reduced MAG3 clearance. The mean error of AUTOROI for all 194 kidneys was 6.66+/-3.77 and 7.31+/-4.52 mm for the left and right kidney, respectively. The physician's error was 6.78+/-2.42 and 6.65+/-2.05 mm for the left and right kidney, respectively. This error difference between AUTOROI and the physician was not statistically significant.
CONCLUSION: AUTOROI provides an objective and promising approach to automated renal ROI detection.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20145580      PMCID: PMC2884994          DOI: 10.1097/MNM.0b013e3283362aa3

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  15 in total

1.  Improved automatic separation of renal parenchyma and pelvis in dynamic renal scintigraphy using fuzzy regions of interest.

Authors:  H Bergmann; E Dworak; B König; A Mostbeck; M Sámal
Journal:  Eur J Nucl Med       Date:  1999-08

2.  Intra- and interoperator variations in region-of-interest drawing and their effect on the measurement of glomerular filtration rates.

Authors:  D R White; A S Houston; W F Sampson; G P Wilkins
Journal:  Clin Nucl Med       Date:  1999-03       Impact factor: 7.794

3.  An assessment of two methods for generating automatic regions of interest.

Authors:  A S Houston; D R White; W F Sampson; M A Macleod; J B Pilkington
Journal:  Nucl Med Commun       Date:  1998-10       Impact factor: 1.690

4.  Cluster analysis for automatic image segmentation in dynamic scintigraphies.

Authors:  P Hannequin; J C Liehn; J Valeyre
Journal:  Nucl Med Commun       Date:  1990-05       Impact factor: 1.690

5.  Relative renal uptake and transit time measurements using functional factor images and fuzzy regions of interest.

Authors:  M Sámal; C C Nimmon; K E Britton; H Bergmann
Journal:  Eur J Nucl Med       Date:  1998-01

6.  Digital processing in cardiac imaging.

Authors:  E V Garcia; A Ezekiel
Journal:  Int J Card Imaging       Date:  1985

7.  RENEX: an expert system for the interpretation of 99mTc-MAG3 scans to detect renal obstruction.

Authors:  Ernest V Garcia; Andrew Taylor; Raghuveer Halkar; Russell Folks; Meghna Krishnan; C David Cooke; Eva Dubovsky
Journal:  J Nucl Med       Date:  2006-02       Impact factor: 10.057

8.  Measurement of renal parenchymal transit time of 99mTc-MAG3 using factor analysis.

Authors:  C D Russell; M V Yester; E V Dubovsky
Journal:  Nuklearmedizin       Date:  1990-08       Impact factor: 1.379

9.  Measuring technetium-99m-MAG3 clearance with an improved camera-based method.

Authors:  A Taylor; P L Corrigan; J Galt; E V Garcia; R Folks; M Jones; A Manatunga; D Eshima
Journal:  J Nucl Med       Date:  1995-09       Impact factor: 10.057

10.  Factor analysis of dynamic structures (FADS) in the diagnosis of renal disease.

Authors:  M A Macleod; A S Houston
Journal:  Eur J Nucl Med       Date:  1989
View more
  3 in total

1.  Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality.

Authors:  Ines Njeh; Kalil Chtourou; Ahmed BenHamida
Journal:  J Healthc Eng       Date:  2020-05-26       Impact factor: 2.682

2.  Reference values for renal size obtained from MAG3 scintigraphy.

Authors:  Andrew T Taylor; Neeta Shenvi; Russell D Folks; Ernest V Garcia; Bital Savir Baruch; Amita Manatunga
Journal:  Clin Nucl Med       Date:  2013-01       Impact factor: 7.794

Review 3.  Computer-assisted diagnosis in renal nuclear medicine: rationale, methodology, and interpretative criteria for diuretic renography.

Authors:  Andrew T Taylor; Ernest V Garcia
Journal:  Semin Nucl Med       Date:  2014-03       Impact factor: 4.446

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.