Literature DB >> 32566114

Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality.

Ines Njeh1,2, Kalil Chtourou3, Ahmed BenHamida1,4.   

Abstract

The ectopic renal function estimation based on a manual region of interest (ROI) extraction could be considered as time consuming. It could also affect the clinical interpretation and thus deviate the therapeutic attitude. For this purpose, we propose an advanced tool to evaluate such function through the dimercaptosuccinic acid (DMSA) kidney scintigraphy scans. Methods. The proposed study has been performed on one hundred patients (fifty cases with normal kidneys and fifty cases with ectopic kidneys). We present our segmentation problems as several cost functions' optimization, each containing two terms: (i) a distribution matching prior, which evaluates a global similarity between distributions, and (ii) a smoothness prior to avoid the occurrence of small, isolated regions in the solution. Obtained following recent bound-relaxation results, the optima of the cost functions yield each kidney region in near real time. The Dice Metric (DM), the Jaccard Index (JI), and the correlation parameter have been adopted as validation parameters in order to evaluate the segmentation results. The obtained relative function of both kidneys has been then compared with that evaluated in clinical routine (planar projection) and then validated statistically by the Bland-Altman plots and the Interclass Correlation Coefficient (ICC). Results. Compared to the expert's manual kidney segmentation, the obtained results have been judged to be acceptable for clinical use with high Mean Dice Metric (MDM) value and high Jaccard Index (JI). The evaluated relative renal function has been different from those calculated by the projection planar method usually used in clinical routines. Conclusion. The proposed system could efficiently extract the renal region. The relative function estimation could be considered as more accurate. In fact, the background noise correction and the attenuation phenomenon, which could yield an error measure for renal ectopia, have been avoided. Our clinical staff members have validated the results and have suggested using such tool in their clinical routines.
Copyright © 2020 Ines Njeh et al.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32566114      PMCID: PMC7271057          DOI: 10.1155/2020/6092305

Source DB:  PubMed          Journal:  J Healthc Eng        ISSN: 2040-2295            Impact factor:   2.682


  21 in total

1.  Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest.

Authors:  Y Inoue; K Yoshikawa; N Yoshioka; T Watanabe; S Saegusa; Y Kaneko; I Yokoyama; K Ohtomo
Journal:  J Nucl Med       Date:  2000-12       Impact factor: 10.057

2.  Fully automatic region of interest selection in glomerular filtration rate estimation from 99mTc-DTPA renogram.

Authors:  Kun-Ju Lin; Jia-Yann Huang; Yung-Sheng Chen
Journal:  J Digit Imaging       Date:  2011-12       Impact factor: 4.056

3.  3D multimodal MRI brain glioma tumor and edema segmentation: a graph cut distribution matching approach.

Authors:  Ines Njeh; Lamia Sallemi; Ismail Ben Ayed; Khalil Chtourou; Stephane Lehericy; Damien Galanaud; Ahmed Ben Hamida
Journal:  Comput Med Imaging Graph       Date:  2014-10-28       Impact factor: 4.790

4.  A technique for analysis of geometric mean renography.

Authors:  John S Fleming
Journal:  Nucl Med Commun       Date:  2006-09       Impact factor: 1.690

5.  Background in the 99mTc DTPA renogram: analysis of intravascular and extravascular components.

Authors:  A M Peters; I Gordon; K Evans; A Todd-Pokropek
Journal:  Am J Physiol Imaging       Date:  1987

Review 6.  Correlation Coefficients: Appropriate Use and Interpretation.

Authors:  Patrick Schober; Christa Boer; Lothar A Schwarte
Journal:  Anesth Analg       Date:  2018-05       Impact factor: 5.108

7.  Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.

Authors:  Ernest V Garcia; Russell Folks; Samuel Pak; Andrew Taylor
Journal:  Nucl Med Commun       Date:  2010-05       Impact factor: 1.690

8.  A critical discussion of intraclass correlation coefficients.

Authors:  R Müller; P Büttner
Journal:  Stat Med       Date:  1994 Dec 15-30       Impact factor: 2.373

9.  Semi-automated renal region of interest selection method using the double-threshold technique: inter-operator variability in quantitating 99mTc-MAG3 renal uptake.

Authors:  Y Tomaru; T Inoue; N Oriuchi; K Takahashi; K Endo
Journal:  Eur J Nucl Med       Date:  1998-01

10.  Subtraction of extra-renal background in 99mTc-DTPA renography: comparison of various regions of interest.

Authors:  M Moonen; G Granerus
Journal:  Clin Physiol       Date:  1992-07
View more
  1 in total

Review 1.  Conventional uroradiology with excretory urography: a forgotten art?

Authors:  Prateek Kumar Madaan; Rohini Gupta Ghasi
Journal:  Br J Radiol       Date:  2022-01-07       Impact factor: 3.629

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.