Literature DB >> 10436196

Improved automatic separation of renal parenchyma and pelvis in dynamic renal scintigraphy using fuzzy regions of interest.

H Bergmann1, E Dworak, B König, A Mostbeck, M Sámal.   

Abstract

The aim of the study was to examine the physiological relevance of factors produced by a modified procedure for factor analysis of dynamic renal studies. Factor analysis has been applied locally to subsets of dynamic renal data which were well defined in both space and time domains. Optimised factor images resulting from different subsets were used as fuzzy regions of interest (ROIs) for the extraction of time-activity curves corresponding to renal parenchyma, renal pelvis, vascular and spatially homogeneous background. The original procedure employed the factor images of renal parenchyma and pelvis resulting from an analysis of the interval between the peaks of parenchymal and pelvic curves. In an attempt to improve the separation of renal parenchyma and pelvis, new fuzzy ROIs were used. They correspond to the factor image of renal uptake obtained from the analysis of the early phase of the study, and to the factor image of the renal pelvis obtained from the outflow phase. The curves generated with the new fuzzy ROIs were compared with those of the original procedure and tested for the presence of known artefacts inconsistent with the expected physiological behaviour. Unlike with the original procedure, no such artefacts were found. The most striking difference was that the pelvic factor curves did not start from zero time of the study but exhibited a physiologically correct initial horizontal zero segment the length of which correlated closely with the minimum parenchymal transit time (r=0.79, n=46, P<0.001). The new method permits easy and reliable application of factor analysis to dynamic renal studies. Problems which remain to be solved are user-independent identification of the optimum factors and suboptimal performance of the method under extreme conditions. Our results provide additional evidence that factor analysis can extract physiologically relevant information quantitatively from dynamic scintigraphic data.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10436196     DOI: 10.1007/s002590050457

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  2 in total

1.  Improved scatter correction with factor analysis for planar and SPECT imaging.

Authors:  Peter Knoll; Arman Rahmim; Selma Gültekin; Martin Šámal; Michael Ljungberg; Siroos Mirzaei; Paul Segars; Boguslaw Szczupak
Journal:  Rev Sci Instrum       Date:  2017-09       Impact factor: 1.523

2.  Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.

Authors:  Ernest V Garcia; Russell Folks; Samuel Pak; Andrew Taylor
Journal:  Nucl Med Commun       Date:  2010-05       Impact factor: 1.690

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.