Wear and oxidative degradation may limit the life span of UHMWPE implants. Cross-linking and stabilisation by vitamin E are proposed to overcome wear and degradation. The present investigation takes a close look to the oxidative behaviour of cross-linked and stabilised UHMWPE. First, the consolidated vitamin E stabilised UHMWPE was qualified in terms of microstructure and homogeneity of the distribution of the additive to be suitable for oxidation profiles over the entire section. Then cross-linked samples with five different concentrations of vitamin E (nil to 1.0%) underwent two different ageing protocols. The first was under pressurized oxygen at 70 degrees C, as defined in the ASTM F 2003 standard with a prolonged period of 60 days, the second was in 5% aqueous hydrogen peroxide solution with iron (III) chloride as catalyst at 50 degrees C. The first accelerated ageing protocol showed that a vitamin E concentration as low as 0.05% is effective to protect irradiated highly cross-linked UHMWPE against oxidation when exposed direct to oxygen. Vitamin E stabilised, highly cross-linked UHMWPE exhibits therefore no oxidation potential origination from the irradiation treatment. Analysis of samples treated by the second chemical ageing yielded, that vitamin E is effective to prolong initial stability against a supplementary attack of hydrogen peroxide and reactive radicals. The time period of stability against the aggressive hydrogen peroxide solution increases with increasing vitamin E content. However, even 0.05% have a marked stabilisation effect. Therefore, such small additions of vitamin E are effective to protect the UHMWPE material against a supplementary exposure to in vivo oxidation after the irradiation treatment. In conclusion, vitamin E shields cross-linked UHMWPE for orthopaedic application against oxidation in the heat of consolidation, during irradiation treatment and finally while implanted in the human body. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20144479     DOI: 10.1016/j.biomaterials.2010.01.076

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  13 in total

Review 1.  Vitamin E diffused, highly crosslinked UHMWPE: a review.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Int Orthop       Date:  2010-12-01       Impact factor: 3.075

2.  Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty.

Authors:  Hannah Spece; Jaclyn T Schachtner; Daniel W MacDonald; Gregg R Klein; Michael A Mont; Gwo-Chin Lee; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2019-07-18       Impact factor: 4.757

Review 3.  Vitamin E-stabilized UHMWPE for total joint implants: a review.

Authors:  Pierangiola Bracco; Ebru Oral
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  The elimination of free radicals in irradiated UHMWPEs with and without vitamin E stabilization by annealing under pressure.

Authors:  Ebru Oral; Bassem W Ghali; Orhun K Muratoglu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-02-24       Impact factor: 3.368

5.  Antioxidant impregnated ultra-high molecular weight polyethylene wear debris particles display increased bone remodeling and a superior osteogenic:osteolytic profile vs. conventional UHMWPE particles in a murine calvaria model.

Authors:  Yu Chen; Nadim J Hallab; Yen-Shuo Liao; Venkat Narayan; Edward M Schwarz; Chao Xie
Journal:  J Orthop Res       Date:  2015-11-23       Impact factor: 3.494

6.  Natural polyphenols enhance stability of crosslinked UHMWPE for joint implants.

Authors:  Jie Shen; Guorong Gao; Xincai Liu; Jun Fu
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

7.  The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty.

Authors:  Dirk Zajonz; Nora Lang; Cathleen Pönick; Melanie Edel; Robert Möbius; Harald Busse; Christoph Josten; Andreas Roth; Johannes K M Fakler
Journal:  Eur J Trauma Emerg Surg       Date:  2019-09-13       Impact factor: 3.693

Review 8.  Surface Texturing of Prosthetic Hip Implant Bearing Surfaces: A Review.

Authors:  Quentin Allen; Bart Raeymaekers
Journal:  J Tribol       Date:  2020-10-05       Impact factor: 2.045

Review 9.  Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review.

Authors:  Antonio Gigante; Carlo Bottegoni; Vincenza Ragone; Lorenzo Banci
Journal:  J Funct Biomater       Date:  2015-09-08

10.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.