Literature DB >> 20144406

Enhanced 911/global position system wizard: a telemedicine application for the prevention of severe hypoglycemia--monitor, alert, and locate.

Eyal Dassau1, Lois Jovanovic, Francis J Doyle, Howard C Zisser.   

Abstract

Intensive insulin therapy has an inherent risk of hypoglycemia that can lead to loss of consciousness, cardiac arrhythmia, seizure, and death ("dead-in-bed syndrome"). This risk of hypoglycemia is a major concern for patients, families, and physicians. The need for an automated system that can alert in the event of severe hypoglycemia is evident. In engineering systems, where there is a risk of malfunction of the primary control system, alert and safety mechanisms are implemented in layers of protection. This concept has been adopted in the proposed system that integrates a hypoglycemia prediction algorithm with a global position system (GPS) locator and short message service such that the current glucose value with the rate of change (ROC) and the location of the subject can be communicated to a predefined list. Furthermore, if the system is linked to the insulin pump, it can suspend the pump or decrease the basal insulin infusion rate to prevent the pending event. The system was evaluated on clinical datasets of glucose tracings from the DexCom Seven system. Glucose tracings were analyzed for hypoglycemia events and then a text message was broadcast to a predefined list of people who were notified with the glucose value, ROC, GPS coordinates, and a Google map of the location. In addition to providing a safety layer to a future artificial pancreas, this system also can be easily implemented in current continuous glucose monitors to help provide information and alerts to people with diabetes.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20144406      PMCID: PMC2787052          DOI: 10.1177/193229680900300632

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  21 in total

Review 1.  Role of diet and insulin treatment of diabetes in pregnancy.

Authors:  L Jovanovic
Journal:  Clin Obstet Gynecol       Date:  2000-03       Impact factor: 2.190

2.  Swiss teleradiology survey: present situation and future trends.

Authors:  Bernhard Lienemann; Juerg Hodler; Marcus Luetolf; Christian W A Pfirrmann
Journal:  Eur Radiol       Date:  2005-04-15       Impact factor: 5.315

Review 3.  Computer-assisted surgery and computer-assisted telesurgery in otorhinolaryngology.

Authors:  Ivica Klapan; Zeljko Vranjes; Ranko Risavi; Ljubimko Simicić; Drago Prgomet; Branko Glusac
Journal:  Ear Nose Throat J       Date:  2006-05       Impact factor: 1.697

4.  Using telemedicine to improve outcomes in diabetes--an emerging technology.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

5.  Dead-in-bed syndrome in diabetes mellitus.

Authors:  P J Weston; G V Gill
Journal:  Lancet       Date:  1997-10-04       Impact factor: 79.321

6.  Dead-in-bed syndrome in diabetes mellitus and hypoglycaemic unawareness.

Authors:  R Hanas
Journal:  Lancet       Date:  1997-08-16       Impact factor: 79.321

7.  Teleradiology in Croatia.

Authors:  S Vuletić
Journal:  J Telemed Telecare       Date:  2001       Impact factor: 6.184

8.  Modular artificial beta-cell system: a prototype for clinical research.

Authors:  Eyal Dassau; Howard Zisser; Cesar C Palerm; Bruce A Buckingham; Lois Jovanovic; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2008-09

9.  Use of digital camera imaging of eye fundus for telemedicine in children suspected of abusive head injury.

Authors:  M Saleh; S Schoenlaub; P Desprez; T Bourcier; D Gaucher; D Astruc; C Speeg-Schatz
Journal:  Br J Ophthalmol       Date:  2008-11-19       Impact factor: 4.638

10.  In silico evaluation platform for artificial pancreatic beta-cell development--a dynamic simulator for closed-loop control with hardware-in-the-loop.

Authors:  Eyal Dassau; Cesar C Palerm; Howard Zisser; Bruce A Buckingham; Lois Jovanovic; Francis J Doyle
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

View more
  16 in total

1.  Clinical hurdles and possible solutions in the implementation of closed-loop control in type 1 diabetes mellitus.

Authors:  Howard Zisser
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

2.  Improved outcomes from diabetes monitoring: the benefits of better adherence, therapy adjustments, patient education, and telemedicine support.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

3.  The role of technology and the chronic care model.

Authors:  Linda M Siminerio
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

Review 4.  Mobile remote-presence devices for point-of-care health care delivery.

Authors:  Ivar Mendez; Michiel C Van den Hof
Journal:  CMAJ       Date:  2013-06-17       Impact factor: 8.262

5.  Design and in silico evaluation of an intraperitoneal-subcutaneous (IP-SC) artificial pancreas.

Authors:  Justin J Lee; Eyal Dassau; Howard Zisser; Francis J Doyle
Journal:  Comput Chem Eng       Date:  2014-11-05       Impact factor: 3.845

6.  In silico evaluation of an artificial pancreas combining exogenous ultrafast-acting technosphere insulin with zone model predictive control.

Authors:  Justin J Lee; Eyal Dassau; Howard Zisser; Rebecca A Harvey; Lois Jovanovič; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

7.  Innovations in technology for the treatment of diabetes: clinical development of the artificial pancreas (an autonomous system).

Authors:  David C Klonoff; Charles L Zimliki; Lcdr Alan Stevens; Patricia Beaston; Arleen Pinkos; Sally Y Choe; Guillermo Arreaza-Rubín; William Heetderks
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

8.  Design of the health monitoring system for the artificial pancreas: low glucose prediction module.

Authors:  Rebecca A Harvey; Eyal Dassau; Howard Zisser; Dale E Seborg; Lois Jovanovič; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

Review 9.  Fault detection and safety in closed-loop artificial pancreas systems.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2014-07-21

10.  Real-Time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas.

Authors:  Eyal Dassau; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Howard Zisser; Lois Jovanovic; H Peter Chase; Darrell M Wilson; Bruce A Buckingham; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-06       Impact factor: 17.152

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.