Literature DB >> 19885271

Modular artificial beta-cell system: a prototype for clinical research.

Eyal Dassau1, Howard Zisser, Cesar C Palerm, Bruce A Buckingham, Lois Jovanovic, Francis J Doyle.   

Abstract

BACKGROUND: The quest toward an artificial beta-cell has been accelerating, propelled by recent technological advances in subcutaneous glucose sensors and insulin pumps. The development and clinical testing of algorithms involves several challenges: communication and data transfer between a sensor and a pump via computer, a human interface presenting real-time information to the physician, safety issues when an automated system is used to administer insulin, and an architecture that supports different sensors, pumps, and control algorithms. These challenges were addressed in the development of a modular artificial beta-cell system for clinical research.
METHODS: The developmental environment of MATLAB (The MathWorks, Inc., Natick, MA) allowed the flexible implementation of communication protocols for different sensors and pumps. The system has a plug-and-play option for the control algorithm and a human interface that presents and logs the data, enforces protocol safety rules, and facilitates physician oversight.
RESULTS: A novel platform for use in clinical research trials was realized as a bridge toward a portable unit. This prototype encapsulates communication between the control algorithm, the pump, and the sensors. Its intuitive human interface presents all the relevant patient information to the physician and allows events to be electronically logged. It facilitates subject safety by way of integrated interlocks, checklists, and alarms.
CONCLUSION: The modular design of the system allows for the robust testing of various sensors and pumps as well as feedback control, meal detection, predictive hypoglycemia alarms, and device-related algorithms to detect sensor or pump failure.

Entities:  

Keywords:  artificial pancreas; closed-loop control; type 1 diabetes mellitus

Year:  2008        PMID: 19885271      PMCID: PMC2769791          DOI: 10.1177/193229680800200518

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  4 in total

1.  Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

Authors:  Roman Hovorka; Valentina Canonico; Ludovic J Chassin; Ulrich Haueter; Massimo Massi-Benedetti; Marco Orsini Federici; Thomas R Pieber; Helga C Schaller; Lukas Schaupp; Thomas Vering; Malgorzata E Wilinska
Journal:  Physiol Meas       Date:  2004-08       Impact factor: 2.833

2.  Detection of a meal using continuous glucose monitoring: implications for an artificial beta-cell.

Authors:  Eyal Dassau; B Wayne Bequette; Bruce A Buckingham; Francis J Doyle
Journal:  Diabetes Care       Date:  2007-10-31       Impact factor: 19.112

Review 3.  A new approach to diabetic control: fuzzy logic and insulin pump technology.

Authors:  Paul Grant
Journal:  Med Eng Phys       Date:  2006-10-18       Impact factor: 2.242

4.  Computer-aided continuous drug infusion: setup and test of a mobile closed-loop system for the continuous automated infusion of insulin.

Authors:  Ralf Dudde; Thomas Vering; Gundula Piechotta; Rainer Hintsche
Journal:  IEEE Trans Inf Technol Biomed       Date:  2006-04
  4 in total
  48 in total

1.  Continuous glucose monitoring considerations for the development of a closed-loop artificial pancreas system.

Authors:  D Barry Keenan; Benyamin Grosman; Harry W Clark; Anirban Roy; Stuart A Weinzimer; Rajiv V Shah; John J Mastrototaro
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

2.  Stress Testing of an Artificial Pancreas System With Pizza and Exercise Leads to Improvements in the System's Fuzzy Logic Controller.

Authors:  Richard Mauseth; Sandra M Lord; Irl B Hirsch; Robert C Kircher; Don P Matheson; Carla J Greenbaum
Journal:  J Diabetes Sci Technol       Date:  2015-09-14

3.  Evaluation of an Artificial Pancreas with Enhanced Model Predictive Control and a Glucose Prediction Trust Index with Unannounced Exercise.

Authors:  Jordan E Pinsker; Alejandro J Laguna Sanz; Joon Bok Lee; Mei Mei Church; Camille Andre; Laura E Lindsey; Francis J Doyle; Eyal Dassau
Journal:  Diabetes Technol Ther       Date:  2018-07       Impact factor: 6.118

4.  Juvenile diabetes research foundation artificial pancreas consortium update.

Authors:  Aaron Kowalski; John W Lum
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

5.  Control to range for diabetes: functionality and modular architecture.

Authors:  Boris Kovatchev; Stephen Patek; Eyal Dassau; Francis J Doyle; Lalo Magni; Giuseppe De Nicolao; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

6.  First clinical evaluation of a new percutaneous optical fiber glucose sensor for continuous glucose monitoring in diabetes.

Authors:  Achim Josef Müller; Monika Knuth; Katharina Sibylle Nikolaus; Roland Krivánek; Frank Küster; Christoph Hasslacher
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

7.  Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2016-06-01       Impact factor: 5.944

8.  Real-Time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas.

Authors:  Eyal Dassau; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Howard Zisser; Lois Jovanovic; H Peter Chase; Darrell M Wilson; Bruce A Buckingham; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-06       Impact factor: 17.152

9.  MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes.

Authors:  Eran Atlas; Revital Nimri; Shahar Miller; Eli A Grunberg; Moshe Phillip
Journal:  Diabetes Care       Date:  2010-02-11       Impact factor: 19.112

10.  Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension.

Authors:  Bruce Buckingham; H Peter Chase; Eyal Dassau; Erin Cobry; Paula Clinton; Victoria Gage; Kimberly Caswell; John Wilkinson; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-03-03       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.