BACKGROUND: The objective of this study was to investigate the performance of a newly proposed insulin titrating algorithm to achieve tight glycemic control in the critically ill. METHODS: A simulation environment with 10 critically ill virtual subjects was employed to evaluate the "I, Pancreas" algorithm proposed by Braithwaite et al. and described in an article in this issue of Journal of Diabetes Science and Technology. The algorithm was coded in MATLAB and was "plugged in" to a simulation environment to provide glucose control in a 48-hour-long simulated study. RESULTS: Mean blood glucose was 6.5 +/- 0.4 mmol/liter (118 +/- 7.8 mg/dl), percentage of time spent in the target glucose range was 38% (32-44%), and the hyperglycemic index was 0.6 (0.4 -1.0) mmol/liter [11.1 (7.7-18.1) mg/dl]. A single episode of mild hypoglycemia at 3.8 mmol/liter (69 mg/dl) was observed during 480 hours of glucose control. CONCLUSION: In this initial in silico evaluation, the "I, Pancreas" algorithm provided a safe control of glucose in the simulated study and achieved tight glycemic control 38% of the time. Copyright 2009 Diabetes Technology Society.
BACKGROUND: The objective of this study was to investigate the performance of a newly proposed insulin titrating algorithm to achieve tight glycemic control in the critically ill. METHODS: A simulation environment with 10 critically ill virtual subjects was employed to evaluate the "I, Pancreas" algorithm proposed by Braithwaite et al. and described in an article in this issue of Journal of Diabetes Science and Technology. The algorithm was coded in MATLAB and was "plugged in" to a simulation environment to provide glucose control in a 48-hour-long simulated study. RESULTS: Mean blood glucose was 6.5 +/- 0.4 mmol/liter (118 +/- 7.8 mg/dl), percentage of time spent in the target glucose range was 38% (32-44%), and the hyperglycemic index was 0.6 (0.4 -1.0) mmol/liter [11.1 (7.7-18.1) mg/dl]. A single episode of mild hypoglycemia at 3.8 mmol/liter (69 mg/dl) was observed during 480 hours of glucose control. CONCLUSION: In this initial in silico evaluation, the "I, Pancreas" algorithm provided a safe control of glucose in the simulated study and achieved tight glycemic control 38% of the time. Copyright 2009 Diabetes Technology Society.
Authors: G van den Berghe; P Wouters; F Weekers; C Verwaest; F Bruyninckx; M Schetz; D Vlasselaers; P Ferdinande; P Lauwers; R Bouillon Journal: N Engl J Med Date: 2001-11-08 Impact factor: 91.245
Authors: Roman Kulnik; Johannes Plank; Christoph Pachler; Malgorzata E Wilinska; Andrea Groselj-Strele; Doris Röthlein; Matthias Wufka; Norman Kachel; Karl Heinz Smolle; Sabine Perl; Thomas Rudolf Pieber; Roman Hovorka; Martin Ellmerer Journal: J Diabetes Sci Technol Date: 2008-11
Authors: Christoph Pachler; Johannes Plank; Heinz Weinhandl; Ludovic J Chassin; Malgorzata E Wilinska; Roman Kulnik; Peter Kaufmann; Karl-Heinz Smolle; Ernst Pilger; Thomas R Pieber; Martin Ellmerer; Roman Hovorka Journal: Intensive Care Med Date: 2008-02-23 Impact factor: 17.440
Authors: Philip A Goldberg; Mark D Siegel; Robert S Sherwin; Joshua I Halickman; Michelle Lee; Valerie A Bailey; Sandy L Lee; James D Dziura; Silvio E Inzucchi Journal: Diabetes Care Date: 2004-02 Impact factor: 19.112
Authors: Jan Blaha; Petr Kopecky; Michal Matias; Roman Hovorka; Jan Kunstyr; Tomas Kotulak; Michal Lips; David Rubes; Martin Stritesky; Jaroslav Lindner; Michal Semrad; Martin Haluzik Journal: Diabetes Care Date: 2009-02-05 Impact factor: 17.152
Authors: Jan Wernerman; Thomas Desaive; Simon Finfer; Luc Foubert; Anthony Furnary; Ulrike Holzinger; Roman Hovorka; Jeffrey Joseph; Mikhail Kosiborod; James Krinsley; Dieter Mesotten; Stanley Nasraway; Olav Rooyackers; Marcus J Schultz; Tom Van Herpe; Robert A Vigersky; Jean-Charles Preiser Journal: Crit Care Date: 2014-06-13 Impact factor: 9.097