Literature DB >> 18297268

Tight glycaemic control by an automated algorithm with time-variant sampling in medical ICU patients.

Christoph Pachler1, Johannes Plank, Heinz Weinhandl, Ludovic J Chassin, Malgorzata E Wilinska, Roman Kulnik, Peter Kaufmann, Karl-Heinz Smolle, Ernst Pilger, Thomas R Pieber, Martin Ellmerer, Roman Hovorka.   

Abstract

OBJECTIVE: Tight glycaemic control (TGC) in critically ill patients improves clinical outcome, but is difficult to establish The primary objective of the present study was to compare glucose control in medical ICU patients applying a computer-based enhanced model predictive control algorithm (eMPC) extended to include time-variant sampling against an implemented glucose management protocol.
DESIGN: Open randomised controlled trial.
SETTING: Nine-bed medical intensive care unit (ICU) in a tertiary teaching hospital. PATIENTS AND PARTICIPANTS: Fifty mechanically ventilated medical ICU patients.
INTERVENTIONS: Patients were included for a study period of up to 72 h. Patients were randomised to the control group (n = 25), treated by an implemented insulin algorithm, or to the eMPC group (n = 25), using the laptop-based algorithm. Target range for blood glucose (BG) was 4.4-6.1 mM. Efficacy was assessed by mean BG, hyperglycaemic index (HGI) and BG sampling interval. Safety was assessed by the number of hypoglycaemic-episodes < 2.2 mM. Each participating nurse filled-in a questionnaire regarding the usability of the algorithm.
MEASUREMENTS AND MAIN RESULTS: BG and HGI were significantly lower in the eMPC group [BG 5.9 mM (5.5-6.3), median (IQR); HGI 0.4 mM (0.2-0.9)] than in control patients [BG 7.4 mM (6.9-8.6), p < 0.001; HGI 1.6 mM (1.1-2.4), p < 0.001]. One hypoglycaemic episode was detected in the eMPC group; no such episodes in the control group. Sampling interval was significantly shorter in the eMPC group [eMPC 117[Symbol: see text]min (+/- 34), mean (+/- SD), vs 174 min (+/- 27); p < 0.001]. Thirty-four nurses filled-in the questionnaire. Thirty answered the question of whether the algorithm could be applied in daily routine in the affirmative.
CONCLUSIONS: The eMPC algorithm was effective in maintaining tight glycaemic control in severely ill medical ICU patients.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18297268     DOI: 10.1007/s00134-008-1033-8

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  28 in total

1.  Hypoglycaemia: the limiting factor in the glycaemic management of the critically ill?

Authors:  P E Cryer
Journal:  Diabetologia       Date:  2006-08       Impact factor: 10.122

2.  Predisposing factors for hypoglycemia in the intensive care unit.

Authors:  Titia M Vriesendorp; Susanne van Santen; J Hans DeVries; Evert de Jonge; Frits R Rosendaal; Marcus J Schultz; Joost B L Hoekstra
Journal:  Crit Care Med       Date:  2006-01       Impact factor: 7.598

Review 3.  Intensive insulin therapy in critical care: a review of 12 protocols.

Authors:  Mark Wilson; Jane Weinreb; Guy W Soo Hoo
Journal:  Diabetes Care       Date:  2007-01-09       Impact factor: 19.112

4.  Failure to achieve glycemic control despite intensive insulin therapy in a medical ICU: incidence and influence on ICU mortality.

Authors:  Jean-Claude Lacherade; Patricia Jabre; Sylvie Bastuji-Garin; David Grimaldi; Pascal Fangio; Valerie Théron; Hervé Outin; Bernard De Jonghe
Journal:  Intensive Care Med       Date:  2007-03-13       Impact factor: 17.440

5.  Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients.

Authors:  Johannes Plank; Jan Blaha; Jeremy Cordingley; Malgorzata E Wilinska; Ludovic J Chassin; Cliff Morgan; Stephen Squire; Martin Haluzik; Jaromir Kremen; Stepan Svacina; Wolfgang Toller; Andreas Plasnik; Martin Ellmerer; Roman Hovorka; Thomas R Pieber
Journal:  Diabetes Care       Date:  2006-02       Impact factor: 19.112

6.  Closing the loop: the adicol experience.

Authors:  Roman Hovorka; Ludovic J Chassin; Malgorzata E Wilinska; Valentina Canonico; Joyce Akwe Akwi; Marco Orsini Federici; Massimo Massi-Benedetti; Ivo Hutzli; Claudio Zaugg; Heiner Kaufmann; Marcel Both; Thomas Vering; Helga C Schaller; Lukas Schaupp; Manfred Bodenlenz; Thomas R Pieber
Journal:  Diabetes Technol Ther       Date:  2004-06       Impact factor: 6.118

7.  Continuous insulin infusion reduces mortality in patients with diabetes undergoing coronary artery bypass grafting.

Authors:  Anthony P Furnary; Guangqiang Gao; Gary L Grunkemeier; YingXing Wu; Kathryn J Zerr; Stephen O Bookin; H Storm Floten; Albert Starr
Journal:  J Thorac Cardiovasc Surg       Date:  2003-05       Impact factor: 5.209

8.  Glycemic control in the ICU: a multicenter survey.

Authors:  Joseph McMullin; Jan Brozek; Roman Jaeschke; Cindy Hamielec; Vinay Dhingra; Graeme Rocker; Andreas Freitag; James Gibson; Deborah Cook
Journal:  Intensive Care Med       Date:  2004-03-30       Impact factor: 17.440

9.  Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group.

Authors: 
Journal:  Lancet       Date:  1998-09-12       Impact factor: 79.321

10.  Standardization of intravenous insulin therapy improves the efficiency and safety of blood glucose control in critically ill adults.

Authors:  Salmaan Kanji; Avinder Singh; Michael Tierney; Hilary Meggison; Lauralyn McIntyre; Paul C Hebert
Journal:  Intensive Care Med       Date:  2004-03-20       Impact factor: 17.440

View more
  32 in total

1.  AP@home: a novel European approach to bring the artificial pancreas home.

Authors:  Lutz Heinemann; Carsten Benesch; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

2.  The metrics of glycaemic control in critical care.

Authors:  Iain M J Mackenzie; Tony Whitehouse; Peter G Nightingale
Journal:  Intensive Care Med       Date:  2011-01-06       Impact factor: 17.440

Review 3.  Diabetes Technology in the Inpatient Setting for Management of Hyperglycemia.

Authors:  Georgia M Davis; Rodolfo J Galindo; Alexandra L Migdal; Guillermo E Umpierrez
Journal:  Endocrinol Metab Clin North Am       Date:  2020-03       Impact factor: 4.741

4.  Barriers and facilitators to the use of computer-based intensive insulin therapy.

Authors:  Thomas R Campion; Lemuel R Waitman; Nancy M Lorenzi; Addison K May; Cynthia S Gadd
Journal:  Int J Med Inform       Date:  2011-10-21       Impact factor: 4.046

5.  An evaluation of "I, Pancreas" algorithm performance in silico.

Authors:  Malgorzata E Wilinska; Marianna Nodale
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

6.  Evaluation of implementation of a fully automated algorithm (enhanced model predictive control) in an interacting infusion pump system for establishment of tight glycemic control in medical intensive care unit patients.

Authors:  Roman Kulnik; Johannes Plank; Christoph Pachler; Malgorzata E Wilinska; Andrea Groselj-Strele; Doris Röthlein; Matthias Wufka; Norman Kachel; Karl Heinz Smolle; Sabine Perl; Thomas Rudolf Pieber; Roman Hovorka; Martin Ellmerer
Journal:  J Diabetes Sci Technol       Date:  2008-11

7.  Tight glycemic control in the hospital.

Authors:  Martin Ellmerer; Christoph Pachler; Johannes Plank
Journal:  J Diabetes Sci Technol       Date:  2008-07

Review 8.  Health technology assessment review: Computerized glucose regulation in the intensive care unit--how to create artificial control.

Authors:  Miriam Hoekstra; Mathijs Vogelzang; Evgeny Verbitskiy; Maarten W N Nijsten
Journal:  Crit Care       Date:  2009-10-16       Impact factor: 9.097

9.  Comparison of three protocols for tight glycemic control in cardiac surgery patients.

Authors:  Jan Blaha; Petr Kopecky; Michal Matias; Roman Hovorka; Jan Kunstyr; Tomas Kotulak; Michal Lips; David Rubes; Martin Stritesky; Jaroslav Lindner; Michal Semrad; Martin Haluzik
Journal:  Diabetes Care       Date:  2009-02-05       Impact factor: 17.152

10.  Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time.

Authors:  Rattan Juneja; Corbin P Roudebush; Stanley A Nasraway; Adam A Golas; Judith Jacobi; Joni Carroll; Deborah Nelson; Victor J Abad; Samuel J Flanders
Journal:  Crit Care       Date:  2009-10-12       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.