Literature DB >> 20142184

A third generation ultra-thin strut cobalt chromium stent: histopathological evaluation in porcine coronary arteries.

Refat Jabara1, Sarah Geva, Henrique B Ribeiro, Jack P Chen, Dongming Hou, Jinsheng Li, Spencer B King, Nicolas Chronos, Keith A Robinson.   

Abstract

AIMS: The present study was designed to evaluate a novel third generation bare-metal stent (BMS) comprised of an ultra-thin-strut, cobalt-chromium platform with fixed geometry, uniform cell size, and superior surface finish in a porcine coronary artery model. METHODS AND
RESULTS: A total of 47 BMS of two types were implanted in pig coronary arteries using QCA to optimise stent apposition: a commercially available cobalt alloy thin-strut stent (91 microm) as control (Driver; n=17), and an ultra-thin-strut (65 microm) cobalt-chromium stent (Protea; n=18). Animals underwent angiographic restudy and termination one week and one month post-implant for coronary artery histology. In addition, 12 overlapping Protea stents were analysed at one month. At one week, comparable thin neointima and mild inflammation were observed in both groups. At one month, Protea demonstrated significantly lower angiographic % stenosis (2+/-1% vs. 17+/-5%, p=0.006), intimal thickness (0.11+/-0.01 mm vs. 0.23+/-0.03 mm, p=0.003), and histologic % area stenosis (19+/-2% vs. 32+/-3%, p=0.003). Mean stent strut injury scores were low and similar between groups. Angiographic % stenosis, intimal thickness, and histologic % area stenosis of overlapping Protea stents were 3+/-1%, 0.13+/-0.01 mm, and 22+/-2%, respectively, and similar to the single Protea group. Stable fibrocellular neointimal incorporation, with complete endothelialisation and minimal inflammation, were observed at one month in all stents, including overlapped Protea segments.
CONCLUSIONS: When compared to a commercially available cobalt alloy BMS, the new third generation Protea stent demonstrated favourable coronary arterial response with significant reduction of neointimal formation in the porcine model. Our results showed how seemingly trivial improvements to the BMS technology can result in substantial biological responses. Future, long-term investigations are needed to ascertain the clinical applicability and implications of these findings.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20142184     DOI: 10.4244/eijv5i5a99

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  6 in total

1.  Low-dose sirolimus-eluting hydroxyapatite coating on stents does not increase platelet activation and adhesion ex vivo.

Authors:  Carlos L Alviar; Armando Tellez; Michael Wang; Pamela Potts; Doug Smith; Manus Tsui; Wladyslaw Budzynski; Albert E Raizner; Neal S Kleiman; Eli I Lev; Juan F Granada; Greg L Kaluza
Journal:  J Thromb Thrombolysis       Date:  2012-07       Impact factor: 2.300

2.  Four-year clinical follow-up of the first-in-man randomized comparison of a novel sirolimus eluting stent with abluminal biodegradable polymer and ultra-thin strut cobalt-chromium alloy: the INSPIRON-I trial.

Authors:  Marcos Danillo Peixoto Oliveira; Expedito E Ribeiro; Carlos M Campos; Henrique B Ribeiro; Bruno L R Faillace; Augusto C Lopes; Rodrigo B Esper; George X Meirelles; Marco A Perin; Alexandre Abizaid; Pedro A Lemos
Journal:  Cardiovasc Diagn Ther       Date:  2015-08

3.  Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease.

Authors:  Luciano Maurício de Abreu Filho; Antonio Artur da Cruz Forte; Marcos Kiyoshi Sumita; Desidério Favarato; George Cesar Ximenes Meireles
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

4.  Ultra-thin strut cobalt chromium bare metal stent usage in a complex real-world setting. (SOLSTICE registry).

Authors:  M J Suttorp; P R Stella; J Dens; J M McKenzie; K S Park; P Frambach
Journal:  Neth Heart J       Date:  2015-02       Impact factor: 2.380

5.  Preliminary Evaluation of Clinical and Angiographic Outcomes with Biodegradable Polymer Coated Sirolimus-Eluting Stent in De Novo Coronary Artery Disease: Results of the MANIPAL-FLEX Study.

Authors:  Ranjan Shetty; Jayesh Prajapati; Umesh Pai; Kiran Shetty
Journal:  Scientifica (Cairo)       Date:  2016-08-14

6.  Prospective evaluation of an ultrathin strut biodegradable polymer-coated sirolimus-eluting stent: 12 months' results from the S-FLEX UK registry.

Authors:  Anirban Choudhury; Scot Garg; Jamie Smith; Andrew Sharp; Sergio Nabais de Araujo; Anoop Chauhan; Nikhil Patel; Benjamin Wrigley; Sudipta Chattopadhyay; Azfar G Zaman
Journal:  BMJ Open       Date:  2019-10-11       Impact factor: 2.692

  6 in total