Literature DB >> 20135690

In vitro investigation of friction under edge-loading conditions for ceramic-on-ceramic total hip prosthesis.

Elhadi Sariali1, Todd Stewart, Zhongming Jin, John Fisher.   

Abstract

Edge-loading generates higher wear rates in ceramic-on-ceramic total hip prosthesis (THP). To investigate the friction coefficient (FC) in these conditions, three alumina ceramic (Biolox Forte) 32 mm-diameter components were tested using a hip friction simulator. The cup was positioned with a 75 degrees abduction angle to achieve edge-loading conditions. The motion was first applied along the edge and then across the edge of the cup. First, tests were conducted under lubricated conditions with 25% bovine serum. Next, to simulate an extremely high contact pressure, the tests were run with the addition of a third body alumina ceramic chip inserted between the edge of the cup and the head. Engineering blue was used to analyze the contact area. Reference values were determined using a 0 degrees cup abduction angle. Edge loading was achieved. The FC increased by three- to sixfold when the motion was applied along the edge, and by 70% when the motion was applied across the edge. However, the FC value was still low (about 0.1), which is similar to metal-on-metal THP. With the third body alumina ceramic particle inserted, the FC was 26 times higher than in the ideal conditions and intermittent squeaking occurred. High cup abduction angles may generate edge-loading and an increase in the friction coefficient for ceramic THP. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20135690     DOI: 10.1002/jor.21100

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  9 in total

1.  Predicting long-term wear performance of hard-on-hard bearing couples: effect of cup orientation.

Authors:  S Shankar; K Gowthaman; M S Uddin
Journal:  Med Biol Eng Comput       Date:  2015-12-30       Impact factor: 2.602

2.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

3.  What factors affect posterior dislocation distance in THA?

Authors:  Jim Nevelos; Aaron Johnson; Christopher Heffernan; James Macintyre; David C Markel; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

4.  Does acetabular inclination angle affect survivorship of alumina-ceramic articulations?

Authors:  Henning R Johansson; Aaron J Johnson; Michael G Zywiel; Marybeth Naughton; Michael A Mont; Peter M Bonutti
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

5.  The lubrication performance of the ceramic-on-ceramic hip implant under starved conditions.

Authors:  Qingen Meng; Jing Wang; Peiran Yang; Zhongmin Jin; John Fisher
Journal:  J Mech Behav Biomed Mater       Date:  2015-06-10

6.  Arthroscopic evaluation and treatment of a squeaking hip. A case report.

Authors:  Jonathan Bellity; Marc Elkaïm; Didier Hannouche; Rémy Nizard
Journal:  BMC Musculoskelet Disord       Date:  2020-12-03       Impact factor: 2.362

7.  Analysis of Chemisorbed Tribo-Film for Ceramic-on-Ceramic Hip Joint Prostheses by Raman Spectroscopy.

Authors:  Risha Rufaqua; Martin Vrbka; Dušan Hemzal; Dipankar Choudhury; David Rebenda; Ivan Křupka; Martin Hartl
Journal:  J Funct Biomater       Date:  2021-05-01

Review 8.  Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty.

Authors:  Guo-Liang Wu; Wei Zhu; Yan Zhao; Qi Ma; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

9.  Three-dimensional templating in hip arthroplasty: the basis for template-directed instrumentation?

Authors:  P Savov; S Budde; S Tsamassiotis; H Windhagen; M Klintschar; M Ettinger
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-10       Impact factor: 3.067

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.