Literature DB >> 20135204

Effect of povidone-iodine addition on the corrosion behavior of cp-Ti in normal saline.

Rahul Bhola1, Shaily M Bhola, Brajendra Mishra, David L Olson.   

Abstract

The effect of various concentrations of povidone-iodine (PI) on the corrosion behavior of a commercially pure titanium alloy (Ti-1) has been investigated in normal saline solution to simulate the povidone-iodine addition in an oral environment. The open circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization measurements have been used to characterize the electrochemical phenomena occurring on the alloy surface. The open circuit potential values for Ti-1 in various concentrations of PI shift considerably towards noble direction as compared to pure normal saline. In the potentiodynamic polarization curve for Ti-1 in various solutions, the cathodic current density has increased for all concentrations of PI and the anodic current density has decreased. Only the 0.1% PI concentration is able to inhibit corrosion of Ti-1 in normal saline and the other higher concentrations studied, accelerate corrosion. The EIS data for Ti-1 in normal saline and in various concentrations of PI follows a one time constant circuit, suggesting the formation of a single passive film on Ti-1 which is not altered by the addition of PI to normal saline.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20135204     DOI: 10.1007/s10856-010-4001-0

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  5 in total

1.  Effects of chlorhexidine and povidone-iodine mouth rinses on the bond strength of an orthodontic composite.

Authors:  Abdullah Demir; Siddik Malkoc; Abdulkadir Sengun; Alp Erdin Koyuturk; Yagmur Sener
Journal:  Angle Orthod       Date:  2005-05       Impact factor: 2.079

2.  Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution.

Authors:  I C Lavos-Valereto; S Wolynec; I Ramires; A C Guastaldi; I Costa
Journal:  J Mater Sci Mater Med       Date:  2004-01       Impact factor: 3.896

3.  Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.

Authors:  N T C Oliveira; A C Guastaldi
Journal:  Acta Biomater       Date:  2008-07-25       Impact factor: 8.947

4.  Clinical application of povidone-iodine oral antiseptic 1% (Betadine mouthwash) and povidone-iodine skin antiseptic 10% (Betadine solution) for the management of odontogenic and deep fascial space infection.

Authors:  Lucia Sarmiento Valderrama
Journal:  Dermatology       Date:  2006       Impact factor: 5.366

5.  Comparison of 5% povidone-iodine solution against 1% povidone-iodine solution in preoperative cataract surgery antisepsis: a prospective randomised double blind study.

Authors:  A W Ferguson; J A Scott; J McGavigan; R A Elton; J McLean; U Schmidt; R Kelkar; B Dhillon
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

  5 in total
  2 in total

1.  Povidone-iodine as a corrosion inhibitor towards a low modulus beta Ti-45Nb implant alloy in a simulated body fluid.

Authors:  S M Bhola; R Bhola; B Mishra; D L Olson
Journal:  J Mater Sci Mater Med       Date:  2011-03-19       Impact factor: 3.896

2.  Povidone-iodine irrigation reduces infection after total hip and knee arthroplasty.

Authors:  Mashael Muwanis; Bardia Barimani; Lucy Luo; Casey K Wang; Ronald Dimentberg; Anthony Albers
Journal:  Arch Orthop Trauma Surg       Date:  2022-04-30       Impact factor: 3.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.