Literature DB >> 21424214

Povidone-iodine as a corrosion inhibitor towards a low modulus beta Ti-45Nb implant alloy in a simulated body fluid.

S M Bhola1, R Bhola, B Mishra, D L Olson.   

Abstract

Povidone-iodine and various bactericidal agents used in dental procedures may affect the corrosion response of an implant/prosthesis in the oral environment. The effect of various concentrations of povidone-iodine (PI) on the corrosion behavior of a low modulus beta titanium alloy, Ti-45Nb, has been investigated in normal saline solution. The open circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization measurements have been used to assess the electrochemical response of the alloy surface on PI addition so as to effectively predict the prosthetic treatment outcome. As the concentration of PI is increased, the corrosion rate decreases, suggested by decreased R(p) values. Povidone-iodine acts as an anodic inhibitor by adsorbing on the anodic sites of the alloy. Addition of PI to a simulated body fluid such as normal saline leads to a decrease in corrosion rate of Ti-45Nb alloy.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21424214     DOI: 10.1007/s10856-011-4268-9

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  6 in total

1.  Corrosion rates of stainless-steel files in different irrigating solutions.

Authors:  M Dartar Oztan; A A Akman; L Zaimoglu; S Bilgiç
Journal:  Int Endod J       Date:  2002-08       Impact factor: 5.264

2.  Effects of chlorhexidine and povidone-iodine mouth rinses on the bond strength of an orthodontic composite.

Authors:  Abdullah Demir; Siddik Malkoc; Abdulkadir Sengun; Alp Erdin Koyuturk; Yagmur Sener
Journal:  Angle Orthod       Date:  2005-05       Impact factor: 2.079

3.  Effect of povidone-iodine addition on the corrosion behavior of cp-Ti in normal saline.

Authors:  Rahul Bhola; Shaily M Bhola; Brajendra Mishra; David L Olson
Journal:  J Mater Sci Mater Med       Date:  2010-02-05       Impact factor: 3.896

4.  Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr.

Authors:  Mitsuo Niinomi
Journal:  Biomaterials       Date:  2003-07       Impact factor: 12.479

5.  Biocompatibility of beta-stabilizing elements of titanium alloys.

Authors:  E Eisenbarth; D Velten; M Müller; R Thull; J Breme
Journal:  Biomaterials       Date:  2004-11       Impact factor: 12.479

6.  Comparison of 5% povidone-iodine solution against 1% povidone-iodine solution in preoperative cataract surgery antisepsis: a prospective randomised double blind study.

Authors:  A W Ferguson; J A Scott; J McGavigan; R A Elton; J McLean; U Schmidt; R Kelkar; B Dhillon
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.