Literature DB >> 15338591

Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution.

I C Lavos-Valereto1, S Wolynec, I Ramires, A C Guastaldi, I Costa.   

Abstract

The influence of potential on electrochemical behavior of Ti-6Al-7Nb alloy under simulated physiological conditions was investigated by electrochemical impedance spectroscopy (EIS). The experimental results were compared with those obtained by potentiodynamic polarization curves. All measurements were carried out in Hank's aerated solution at 25 degrees C, at pH 7.8 and at different potentials (corrosion potential, 0 mV(SCE), 1000 mV(SCE), and 2000 mV(SCE)). The EIS spectra exhibited a two-step or a two-time constant system, suggesting the formation of a two-layer oxide film on the metal surface. The high corrosion resistance, displayed by this alloy in electrochemical polarization tests, is due to the dense inner layer, while its osseointegration ability can be ascribed to the presence of the outer porous layer.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15338591     DOI: 10.1023/b:jmsm.0000010097.86245.74

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  7 in total

1.  Electrochemical corrosion of titanium and titanium-based alloys.

Authors:  C Kuphasuk; Y Oshida; C J Andres; S T Hovijitra; M T Barco; D T Brown
Journal:  J Prosthet Dent       Date:  2001-02       Impact factor: 3.426

2.  A study of histological responses from Ti-6Al-7Nb alloy dental implants with and without plasma-sprayed hydroxyapatite coating in dogs.

Authors:  I C Lavos-Valereto; B König; C Rossa; E Marcantonio; A C Zavaglia
Journal:  J Mater Sci Mater Med       Date:  2001-03       Impact factor: 3.896

3.  Electrochemical characterization of cast titanium alloys.

Authors:  Zhuo Cai; Ty Shafer; Ikuya Watanabe; Martha E Nunn; Toru Okabe
Journal:  Biomaterials       Date:  2003-01       Impact factor: 12.479

4.  Structural and electrochemical examinations of PACVD TiO2 films in Ringer solution.

Authors:  J Głuszek; J Masalski; P Furman; K Nitsch
Journal:  Biomaterials       Date:  1997-06       Impact factor: 12.479

5.  The effect of nitrogen diffusion hardening on the surface chemistry and scratch resistance of Ti-6A1-4V alloy.

Authors:  R Venugopalan; J J Weimer; M A George; L C Lucas
Journal:  Biomaterials       Date:  2000-08       Impact factor: 12.479

6.  The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating in Hank's solution.

Authors:  I C Lavos-Valereto; I Costa; S Wolynec
Journal:  J Biomed Mater Res       Date:  2002

7.  Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide.

Authors:  J Pan; D Thierry; C Leygraf
Journal:  J Biomed Mater Res       Date:  1994-01
  7 in total
  18 in total

1.  In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy.

Authors:  E Vasilescu; P Drob; D Raducanu; V D Cojocaru; I Cinca; D Iordachescu; R Ion; M Popa; C Vasilescu
Journal:  J Mater Sci Mater Med       Date:  2010-03-25       Impact factor: 3.896

2.  Electrochemical and mechanical behavior of laser processed Ti-6Al-4V surface in Ringer's physiological solution.

Authors:  Raghuvir Singh; S K Tiwari; Suman K Mishra; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2011-06-10       Impact factor: 3.896

3.  Effect of povidone-iodine addition on the corrosion behavior of cp-Ti in normal saline.

Authors:  Rahul Bhola; Shaily M Bhola; Brajendra Mishra; David L Olson
Journal:  J Mater Sci Mater Med       Date:  2010-02-05       Impact factor: 3.896

4.  Electrochemical behavior and corrosion resistance of Ti-15Mo alloy in naturally-aerated solutions, containing chloride and fluoride ions.

Authors:  A V Rodrigues; N T C Oliveira; M L dos Santos; A C Guastaldi
Journal:  J Mater Sci Mater Med       Date:  2015-01-11       Impact factor: 3.896

5.  Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.

Authors:  F Rosalbino; S Delsante; G Borzone; G Scavino
Journal:  J Mater Sci Mater Med       Date:  2012-03-02       Impact factor: 3.896

6.  The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions.

Authors:  S Radice; J Yao; J Babauta; M P Laurent; M A Wimmer
Journal:  Materialia (Oxf)       Date:  2019-05-10

7.  Corrosion behaviour of β-Ti20Mo alloy in artificial saliva.

Authors:  Daniel Mareci; Romeu Chelariu; Ioan Dan; Doina-Margareta Gordin; Thierry Gloriant
Journal:  J Mater Sci Mater Med       Date:  2010-08-15       Impact factor: 3.896

8.  An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications.

Authors:  B Bozzini; P Carlino; L D'Urzo; V Pepe; C Mele; F Venturo
Journal:  J Mater Sci Mater Med       Date:  2008-06-27       Impact factor: 3.896

9.  The biocompatibility of titanium in a buffer solution: compared effects of a thin film of TiO2 deposited by MOCVD and of collagen deposited from a gel.

Authors:  Simona Popescu; Ioana Demetrescu; Christos Sarantopoulos; Alain N Gleizes; Dana Iordachescu
Journal:  J Mater Sci Mater Med       Date:  2007-06-12       Impact factor: 3.896

10.  Testing the Test: A Comparative Study of Marine Microbial Corrosion under Laboratory and Field Conditions.

Authors:  Camila Canales; Carlos Galarce; Francisca Rubio; Fabiola Pineda; Javiera Anguita; Ramón Barros; Mirtala Parragué; Leslie K Daille; Javiera Aguirre; Francisco Armijo; Gonzalo E Pizarro; Magdalena Walczak; Rodrigo De la Iglesia; Sergio A Navarrete; Ignacio T Vargas
Journal:  ACS Omega       Date:  2021-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.