Literature DB >> 20131358

Validation of multi-detector computed tomography as a non-invasive method for measuring ovarian volume in macaques (Macaca fascicularis).

Jeryl C Jones1, Susan E Appt, Stephen R Werre, Joshua C Tan, Jay R Kaplan.   

Abstract

The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non-invasive technique for measuring the ovarian volume in macaques.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20131358      PMCID: PMC3741054          DOI: 10.1002/ajp.20807

Source DB:  PubMed          Journal:  Am J Primatol        ISSN: 0275-2565            Impact factor:   2.371


  41 in total

Review 1.  Examining test-retest reliability: an intra-class correlation approach.

Authors:  Miaofen Yen; Li-Hua Lo
Journal:  Nurs Res       Date:  2002 Jan-Feb       Impact factor: 2.381

2.  The reliability and validity of three dimensional ultrasound volumetric measurements using an in vitro balloon and in vivo uterine model.

Authors:  T Farrell; J R Leslie; P F Chien; P Agustsson
Journal:  BJOG       Date:  2001-06       Impact factor: 6.531

3.  Ovarian volume related to age.

Authors:  E J Pavlik; P D DePriest; H H Gallion; F R Ueland; M B Reedy; R J Kryscio; J R van Nagell
Journal:  Gynecol Oncol       Date:  2000-06       Impact factor: 5.482

4.  Multidetector row CT: principles and clinical applications.

Authors:  Karen M Horton; Sheila Sheth; Frank Corl; Elliot K Fishman
Journal:  Crit Rev Comput Tomogr       Date:  2002

5.  CT appearance of pediatric ovaries and uterus.

Authors:  C K Rigsby; M J Siegel
Journal:  J Comput Assist Tomogr       Date:  1994 Jan-Feb       Impact factor: 1.826

6.  Accuracy of volume measurements of computed tomography and magnetic resonance imaging phantoms by three-dimensional reconstruction and preliminary clinical application.

Authors:  D G Disler; D S Marr; D I Rosenthal
Journal:  Invest Radiol       Date:  1994-08       Impact factor: 6.016

7.  CT assessment of tumour response to treatment: comparison of linear, cross-sectional and volumetric measures of tumour size.

Authors:  S A Sohaib; B Turner; J A Hanson; M Farquharson; R T Oliver; R H Reznek
Journal:  Br J Radiol       Date:  2000-11       Impact factor: 3.039

8.  Computed tomography, diagnosis, staging and follow-up of pure granulosa cell tumour of the ovary.

Authors:  J E MacSweeney; D M King
Journal:  Clin Radiol       Date:  1994-04       Impact factor: 2.350

9.  Age-related changes in ovarian volume, antral follicle counts and basal follicle stimulating hormone levels: comparison between fertile and infertile women.

Authors:  M Erdem; A Erdem; K Biberoglu; M Arslan
Journal:  Gynecol Endocrinol       Date:  2003-06       Impact factor: 2.260

10.  Comparison of the accuracy of CT volume calculated by circumscription to prolate ellipsoid volume (bidimensional measurement multiplied by coronal long axis).

Authors:  Ali M Rkein; Chivonne Harrigal; Arnold C Friedman; Daniel Persky; Elizabeth Krupinski
Journal:  Acad Radiol       Date:  2009-02       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.