Literature DB >> 20129579

Use of balloon aortic valvuloplasty to size the aortic annulus before implantation of a balloon-expandable transcatheter heart valve.

Vasilis C Babaliaros1, Zahid Junagadhwalla, Stamatios Lerakis, Vinod Thourani, David Liff, Edward Chen, Thomas Vassiliades, Clay Chappell, Nathan Gross, Ateet Patel, Sharon Howell, Jacob T Green, Emir Veledar, Robert Guyton, Peter C Block.   

Abstract

OBJECTIVES: Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size.
BACKGROUND: Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implantation.
METHODS: Twenty-seven patients underwent sizing of the aortic annulus by BAV and TEE. We implanted the minimal THV size that was greater than the annulus measured by BAV.
RESULTS: The annulus measured by TEE was 21.3 +/- 1.6 mm and by BAV was 22.6 +/- 1.8 mm (p < 0.001). The number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). Fourteen patients (52%) required upsizing of the initial balloon suggested by TEE; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). No change in aortic insufficiency or hemodynamic instability occurred with BAV. Fifteen patients (56%) received a 23-mm THV; 12 patients a 26-mm THV. No coronary occlusion, annular damage, or THV embolization occurred. Paravalvular leak was grade <or=1 in all patients. In 7 patients (26%), balloon sizing resulted in selection of a specific THV size that could not be done by TEE alone.
CONCLUSIONS: BAV sizing of the aortic annulus is safe and is an important adjunct to TEE when selecting THV size. Implanting the minimal THV greater than the BAV annulus size resulted in no adverse events. These data suggest that use of BAV for THV selection may improve the safety and efficacy of THV implantation. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20129579     DOI: 10.1016/j.jcin.2009.09.017

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  12 in total

1.  Transcatheter resection of the native aortic valve prior to endovalve implantation - A rational approach to reduce TAVI-induced complications.

Authors:  Parla Astarci; Pierre-Yves Etienne; Benoit Raucent; Xavier Bollen; Kahn Tranduy; David Glineur; Laurent Dekerchove; Philippe Noirhomme; Gébrine Elkhoury
Journal:  Ann Cardiothorac Surg       Date:  2012-07

2.  Sizing the aortic annulus.

Authors:  Alfredo G Cerillo; Massimiliano Mariani; Sergio Berti; Mattia Glauber
Journal:  Ann Cardiothorac Surg       Date:  2012-07

3.  Time to revisit role of transcatheter balloon aortic valvuloplasty: a bridge-therapy to subsequent treatment case report.

Authors:  Akira Furuta; Hideyuki Shimizu; Takashi Hachiya; Yohei Ohno; Hiroyuki Kawajiri; Akio Kawamura; Kiyokazu Kokaji; Ryohei Yozu; Keiichi Fukuda
Journal:  Heart Vessels       Date:  2012-07-25       Impact factor: 2.037

4.  Valvular leak after transcatheter aortic valve implantation: a clinician update on epidemiology, pathophysiology and clinical implications.

Authors:  Giuseppe Tarantini; Valeria Gasparetto; Massimo Napodano; Chiara Fraccaro; Gino Gerosa; Giambattista Isabella
Journal:  Am J Cardiovasc Dis       Date:  2011-09-10

5.  Two-in-one aortic valve sizing and valvuloplasty conductance balloon catheter.

Authors:  Mark C Svendsen; Anjan K Sinha; Zachary C Berwick; William Combs; Shawn D Teague; Thierry Lefevre; Vasilis Babaliaros; Ghassan Kassab
Journal:  Catheter Cardiovasc Interv       Date:  2015-01-30       Impact factor: 2.692

6.  Balloon sizing during transcatheter aortic valve implantation : Comparison of different valve morphologies.

Authors:  Y-N Xu; T-Y Xiong; Y-J Li; Y-B Liao; Z-G Zhao; X Wei; Y Feng; M Chen
Journal:  Herz       Date:  2018-06-05       Impact factor: 1.443

Review 7.  Multi-modality imaging of the aortic valve in the era of transcatheter aortic valve replacement: a guide for patient selection, valve selection, and valve delivery.

Authors:  Michael Ragosta
Journal:  J Cardiovasc Transl Res       Date:  2013-08-14       Impact factor: 4.132

Review 8.  Role of Echocardiography Before Transcatheter Aortic Valve Implantation (TAVI).

Authors:  Sveeta Badiani; Sanjeev Bhattacharyya; Guy Lloyd
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

9.  CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI)-predictive value and optimal thresholds for major anatomic parameters.

Authors:  Florian Schwarz; Philipp Lange; Dominik Zinsser; Martin Greif; Peter Boekstegers; Christoph Schmitz; Maximilian F Reiser; Christian Kupatt; Hans C Becker
Journal:  PLoS One       Date:  2014-08-01       Impact factor: 3.240

10.  Numerical model of a valvuloplasty balloon: in vitro validation in a rapid-prototyped phantom.

Authors:  Benedetta Biffi; Giorgia M Bosi; Valentina Lintas; Rod Jones; Spyros Tzamtzis; Gaetano Burriesci; Francesco Migliavacca; Andrew M Taylor; Silvia Schievano; Giovanni Biglino
Journal:  Biomed Eng Online       Date:  2016-04-12       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.