Literature DB >> 20124668

In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays.

S Negi1, R Bhandari, L Rieth, F Solzbacher.   

Abstract

Neural interfaces connect signal processing electronics to the nervous system via implanted microelectrode arrays such as the Utah electrode array (UEA). The active sites of the UEA are coated with thin films of either platinum (Pt) or iridium oxide (IrOx). Pt and IrOx have attracted attention as a stimulating or recording material due to their ability to transfer between ionic and electronic current and to resist corrosion. The physical, mechanical, chemical, electrical and optical properties of thin films depend on the method and deposition parameters used to deposit the films. In this work, surface morphology, impedance and charge capacity of Pt and sputtered iridium oxide film (SIROF) were investigated and compared with each other. UEAs with similar electrode area and shape were employed in this study. DC sputtering was used to deposit Pt films and pulsed-dc reactive sputtering was used to deposit SIROF. The electrodes coated with SIROF and Pt were characterized by scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and potential transient measurements to measure charge injection capacity (CIC). SIROF and Pt selectively deposited on the electrode tip had dendrite and granular microstructure, respectively. The CIC of unbiased SIROF and Pt was 2 and 0.3 mC cm(-2), respectively. The average impedance at 1 kHz, of SIROF and Pt electrodes, was 6 kOmega and 125 kOmega, respectively. Low impedance and high CIC make SIROF promising stimulation/recording material for neural prosthetic applications.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20124668     DOI: 10.1088/1748-6041/5/1/015007

Source DB:  PubMed          Journal:  Biomed Mater        ISSN: 1748-6041            Impact factor:   3.715


  38 in total

1.  Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex.

Authors:  Sungshin Kim; Thierri Callier; Gregg A Tabot; Robert A Gaunt; Francesco V Tenore; Sliman J Bensmaia
Journal:  Proc Natl Acad Sci U S A       Date:  2015-10-26       Impact factor: 11.205

2.  Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation.

Authors:  Xiliang Luo; Cassandra L Weaver; David D Zhou; Robert Greenberg; Xinyan T Cui
Journal:  Biomaterials       Date:  2011-05-20       Impact factor: 12.479

3.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

4.  Zebrafish needle EMG: a new tool for high-throughput drug screens.

Authors:  Sung-Joon Cho; Tai-Seung Nam; Donghak Byun; Seok-Yong Choi; Myeong-Kyu Kim; Sohee Kim
Journal:  J Neurophysiol       Date:  2015-07-15       Impact factor: 2.714

5.  The effect of chronic intracortical microstimulation on the electrode-tissue interface.

Authors:  Kevin H Chen; John F Dammann; Jessica L Boback; Francesco V Tenore; Kevin J Otto; Robert A Gaunt; Sliman J Bensmaia
Journal:  J Neural Eng       Date:  2014-02-06       Impact factor: 5.379

6.  Continuous Direct Current Nerve Block Using Multi Contact High Capacitance Electrodes.

Authors:  Tina Vrabec; Niloy Bhadra; Gustaf Van Acker; Narendra Bhadra; Kevin Kilgore
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2016-07-09       Impact factor: 3.802

7.  A computational model that predicts behavioral sensitivity to intracortical microstimulation.

Authors:  Sungshin Kim; Thierri Callier; Sliman J Bensmaia
Journal:  J Neural Eng       Date:  2016-12-15       Impact factor: 5.379

8.  Chronic in vivo stability assessment of carbon fiber microelectrode arrays.

Authors:  Paras R Patel; Huanan Zhang; Matthew T Robbins; Justin B Nofar; Shaun P Marshall; Michael J Kobylarek; Takashi D Y Kozai; Nicholas A Kotov; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2016-10-05       Impact factor: 5.379

9.  A Wafer-Scale Etching Technique for High Aspect Ratio Implantable MEMS Structures.

Authors:  R Bhandari; S Negi; L Rieth; F Solzbacher
Journal:  Sens Actuators A Phys       Date:  2010-07-01       Impact factor: 3.407

10.  Excimer laser deinsulation of Parylene-C on iridium for use in an activated iridium oxide film-coated Utah electrode array.

Authors:  Je-Min Yoo; Sandeep Negi; Prashant Tathireddy; Florian Solzbacher; Jong-In Song; Loren W Rieth
Journal:  J Neurosci Methods       Date:  2013-02-28       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.