Literature DB >> 23990118

Successful repair of aortic annulus rupture during transcatheter aortic valve replacement using extracorporeal membrane oxygenation support.

Smita I Negi1, Jay Patel, Manish Patel, Pranav Loyalka, Biswajit Kar, Igor Gregoric.   

Abstract

Aortic annular rupture is a rare and much dreaded complication of transcatheter aortic valve replacement. Device oversizing to prevent post-procedural paravalvular leak is the most commonly identified cause of this complication. However, mechanical stress in a heavily calcified non-compliant vessel can also lead to annular rupture in this older population. We describe a case of aortic annular rupture with involvement of right coronary artery ostium leading to cardiac tamponade and cardiac arrest, successfully managed by extracorporeal membrane oxygenation support, open drainage of the pericardial space, pericardial patching of the defect and bypass of the affected vessel with excellent post-procedural results.

Entities:  

Mesh:

Year:  2013        PMID: 23990118     DOI: 10.1007/s11748-013-0312-7

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  8 in total

1.  Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients.

Authors:  Rüdiger Lange; Sabine Bleiziffer; Nicolo Piazza; Domenico Mazzitelli; Andrea Hutter; Peter Tassani-Prell; Jean-Claude Laborde; Robert Bauernschmitt
Journal:  Eur J Cardiothorac Surg       Date:  2011-04-22       Impact factor: 4.191

2.  Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium.

Authors:  Martin B Leon; Nicolo Piazza; Eugenia Nikolsky; Eugene H Blackstone; Donald E Cutlip; Arie Pieter Kappetein; Mitchell W Krucoff; Michael Mack; Roxana Mehran; Craig Miller; Marie-angéle Morel; John Petersen; Jeffrey J Popma; Johanna J M Takkenberg; Alec Vahanian; Gerrit-Anne van Es; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys
Journal:  J Am Coll Cardiol       Date:  2011-01-07       Impact factor: 24.094

Review 3.  Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.

Authors:  Jean-Bernard Masson; Jan Kovac; Gerhard Schuler; Jian Ye; Anson Cheung; Samir Kapadia; Murat E Tuzcu; Susheel Kodali; Martin B Leon; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

4.  True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: impact of learning curve on vascular complications.

Authors:  Kentaro Hayashida; Thierry Lefèvre; Bernard Chevalier; Thomas Hovasse; Mauro Romano; Philippe Garot; Darren Mylotte; Jhonathan Uribe; Arnaud Farge; Patrick Donzeau-Gouge; Erik Bouvier; Bertrand Cormier; Marie-Claude Morice
Journal:  JACC Cardiovasc Interv       Date:  2012-02       Impact factor: 11.195

5.  Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation.

Authors:  David Messika-Zeitoun; Jean-Michel Serfaty; Eric Brochet; Gregory Ducrocq; Laurent Lepage; Delphine Detaint; Fabien Hyafil; Dominique Himbert; Nicoletta Pasi; Jean-Pierre Laissy; Bernard Iung; Alec Vahanian
Journal:  J Am Coll Cardiol       Date:  2010-01-19       Impact factor: 24.094

6.  Palliative percutaneous aortic balloon valvuloplasty before noncardiac operations and invasive diagnostic procedures.

Authors:  S N Hayes; D R Holmes; R A Nishimura; G S Reeder
Journal:  Mayo Clin Proc       Date:  1989-07       Impact factor: 7.616

7.  Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure.

Authors:  Stefan Toggweiler; Ronen Gurvitch; Jonathon Leipsic; David A Wood; Alexander B Willson; Ronald K Binder; Anson Cheung; Jian Ye; John G Webb
Journal:  J Am Coll Cardiol       Date:  2012-01-10       Impact factor: 24.094

8.  Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium.

Authors:  Martin B Leon; Nicolo Piazza; Eugenia Nikolsky; Eugene H Blackstone; Donald E Cutlip; Arie Pieter Kappetein; Mitchell W Krucoff; Michael Mack; Roxana Mehran; Craig Miller; Marie-Angèle Morel; John Petersen; Jeffrey J Popma; Johanna J M Takkenberg; Alec Vahanian; Gerrit-Anne van Es; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys
Journal:  Eur Heart J       Date:  2011-01-06       Impact factor: 29.983

  8 in total
  1 in total

1.  Use of extracorporeal membrane oxygenation in complicated transcatheter aortic valve replacement.

Authors:  Kyokun Uehara; Kenji Minakata; Naritatsu Saito; Masao Imai; Hiroki Daijo; Taro Nakatsu; Kazuhisa Sakamoto; Kazuhiro Yamazaki; Takeshi Kimura; Ryuzo Sakata
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-02-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.