Literature DB >> 22710987

Comparison of aortic root measurements in patients undergoing transapical aortic valve implantation (TA-AVI) using three-dimensional rotational angiography (3D-RA) and multislice computed tomography (MSCT): differences and variability.

Lukas H J Lehmkuhl1, Konstantin von Aspern, Borek Foldyna, Matthias Grothoff, Stefan Nitzsche, Joerg Kempfert, Ardawan Rastan, Axel Linke, Friedrich W Mohr, Alois Noettling, Thomas Walther, Matthias Gutberlet.   

Abstract

To evaluate for the first time the degree of compliance between conventional multislice computed tomography (MSCT) and three-dimensional rotational angiography (3D-RA) in measuring relevant dimensions of the aortic annulus, the aortic root and the thoracic aorta in patients undergoing TA-AVI. Twenty-seven patients (82 ± 11 years) with severe aortic stenosis received contrast enhanced ECG gated MSCT prior to TA-AVI and intra-procedural rotational angiography. The aortic annulus size, the distance to the coronary ostia and diameters of the aortic root and the thoracic aorta were measured with both methods by two observers blinded to each other. Linear regression and Bland-Altman analysis were performed to determine the degree of compliance between both methods. The limits of agreement were within two standard deviations for all measurements and with high correlation especially for the supra-annular dimensions. Sizing of the aortic annulus revealed lower interobserver variability for MSCT than for 3D-RA with a maximum deviation of 2.1 ± 2.5 and 1.7 ± 2.8 mm for diameter measurements and for the effective diameter, respectively. With current protocols intra-procedural 3D-RA provides good image quality especially for structures above the aortic annulus. Due to a lower interobserver variability in sizing the aortic annulus MSCT remains more suitable for aortic root assessment prior to TA-AVI.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22710987     DOI: 10.1007/s10554-012-0081-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  19 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

Review 2.  [Effects of aging on kidney function and implications for medical practice].

Authors:  M Rainfray; S Richard-Harston; N Salles-Montaudon; J P Emeriau
Journal:  Presse Med       Date:  2000 Jul 8-15       Impact factor: 1.228

3.  Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method.

Authors:  Philipp Blanke; Matthias Siepe; Jochen Reinöhl; Manfred Zehender; Friedhelm Beyersdorf; Christian Schlensak; Mathias Langer; Gregor Pache
Journal:  Eur J Cardiothorac Surg       Date:  2010-05-15       Impact factor: 4.191

4.  Automatic aorta segmentation and valve landmark detection in C-arm CT: application to aortic valve implantation.

Authors:  Yefeng Zheng; Matthias John; Rui Liao; Jan Boese; Uwe Kirschstein; Bogdan Georgescu; S Kevin Zhou; Jörg Kempfert; Thomas Walther; Gernot Brockmann; Dorin Comaniciu
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

5.  System to guide transcatheter aortic valve implantations based on interventional C-arm CT imaging.

Authors:  Matthias John; Rui Liao; Yefeng Zheng; Alois Nöttling; Jan Boese; Uwe Kirschstein; Jörg Kempfert; Thomas Walther
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

Review 6.  Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve.

Authors:  Nicoló Piazza; Peter de Jaegere; Carl Schultz; Anton E Becker; Patrick W Serruys; Robert H Anderson
Journal:  Circ Cardiovasc Interv       Date:  2008-08       Impact factor: 6.546

7.  Dyna-CT during minimally invasive off-pump transapical aortic valve implantation.

Authors:  Jörg Kempfert; Volkmar Falk; Gerhard Schuler; Axel Linke; Denis Merk; Friedrich W Mohr; Thomas Walther
Journal:  Ann Thorac Surg       Date:  2009-12       Impact factor: 4.330

8.  Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.

Authors:  Arnold C T Ng; Victoria Delgado; Frank van der Kley; Miriam Shanks; Nico R L van de Veire; Matteo Bertini; Gaetano Nucifora; Rutger J van Bommel; Laurens F Tops; Arend de Weger; Giuseppe Tavilla; Albert de Roos; Lucia J Kroft; Dominic Y Leung; Joanne Schuijf; Martin J Schalij; Jeroen J Bax
Journal:  Circ Cardiovasc Imaging       Date:  2009-11-17       Impact factor: 7.792

9.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?

Authors:  Carl J Schultz; Adriaan Moelker; Nicolo Piazza; Apostolos Tzikas; Amber Otten; Rutger J Nuis; Lisan A Neefjes; Robert J van Geuns; Pim de Feyter; Gabriel Krestin; Patrick W Serruys; Peter P T de Jaegere
Journal:  Eur Heart J       Date:  2009-12-07       Impact factor: 29.983

10.  Initial observations of endovascular aneurysm repair using Dyna-CT.

Authors:  Kari Ravn Eide; Asbjørn Ødegård; Hans Olav Myhre; Olav Haraldseth
Journal:  J Endovasc Ther       Date:  2007-02       Impact factor: 3.487

View more
  3 in total

1.  Editorial comment.

Authors:  Volkmar Falk
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-30       Impact factor: 2.357

2.  Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.

Authors:  K von Aspern; B Foldyna; C D Etz; A Hoyer; F Girrbach; D Holzhey; C Lücke; M Grothoff; A Linke; F W Mohr; M Gutberlet; L Lehmkuhl
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-28       Impact factor: 2.357

3.  Determinants of image quality of rotational angiography for on-line assessment of frame geometry after transcatheter aortic valve implantation.

Authors:  Ramón Rodríguez-Olivares; Nahid El Faquir; Zouhair Rahhab; Anne-Marie Maugenest; Nicolas M Van Mieghem; Carl Schultz; Guenter Lauritsch; Peter P T de Jaegere
Journal:  Int J Cardiovasc Imaging       Date:  2016-05-02       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.