Literature DB >> 20100639

Clinical applications of volumetric modulated arc therapy.

Martha M Matuszak1, Di Yan, Inga Grills, Alvaro Martinez.   

Abstract

PURPOSE: To present treatment planning case studies for several treatment sites for which volumetric modulated arc therapy (VMAT) could have a positive impact; and to share an initial clinical experience with VMAT for stereotactic body radiotherapy (SBRT). METHODS AND MATERIALS: Four case studies are presented to show the potential benefit of VMAT compared with conformal and intensity-modulated radiotherapy (IMRT) techniques in pediatric cancer, bone marrow-sparing whole-abdominopelvic irradiation (WAPI), and SBRT of the lung and spine. Details of clinical implementation of VMAT for SBRT are presented. The VMAT plans are compared with conventional techniques in terms of dosimetric quality and delivery efficiency.
RESULTS: Volumetric modulated arc therapy reduced the treatment time of spine SBRT by 37% and improved isodose conformality. Conformal and VMAT techniques for lung SBRT had similar dosimetric quality, but VMAT had improved target coverage and took 59% less time to deliver, although monitor units were increased by 5%. In a complex pediatric pelvic example, VMAT reduced treatment time by 78% and monitor units by 25% compared with IMRT. A double-isocenter VMAT technique for WAPI can spare bone marrow while maintaining good delivery efficiency.
CONCLUSIONS: Volumetric modulated arc therapy is a new technology that may benefit different patient populations, including pediatric cancer patients and those undergoing concurrent chemotherapy and WAPI. Volumetric modulated arc therapy has been used and shown to be beneficial for significantly improving delivery efficiency of lung and spine SBRT. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20100639     DOI: 10.1016/j.ijrobp.2009.08.032

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  40 in total

Review 1.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

2.  Effect of photon-beam energy on VMAT and IMRT treatment plan quality and dosimetric accuracy for advanced prostate cancer.

Authors:  Marlies Pasler; Dietmar Georg; Holger Wirtz; Johannes Lutterbach
Journal:  Strahlenther Onkol       Date:  2011-11-29       Impact factor: 3.621

3.  Single fraction spine stereotactic ablative body radiotherapy with volumetric modulated arc therapy.

Authors:  Matthew M Gestaut; Nitika Thawani; Sangroh Kim; Veera R Gutti; Sameer Jhavar; Niloyjyoti Deb; Andrew Morrow; Russell A Ward; Jason H Huang; Mehul Patel
Journal:  J Neurooncol       Date:  2017-04-13       Impact factor: 4.130

4.  Penalization of aperture complexity in inversely planned volumetric modulated arc therapy.

Authors:  Kelly C Younge; Martha M Matuszak; Jean M Moran; Daniel L McShan; Benedick A Fraass; Donald A Roberts
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Volumetric modulated arc radiotherapy for limited osteosclerotic myeloma.

Authors:  Aurélie Robles; Antonin Levy; Coralie Moncharmont; Lamine Farid; Jean-Baptiste Guy; Nadia Malkoun; Lysian Cartier; Cyrus Chargari; Isabelle Guichard; Jean-Noël Talabard; Guy de Laroche; Nicolas Magné
Journal:  World J Radiol       Date:  2013-04-28

Review 6.  Influence of segment width on plan quality for volumetric modulated arc based stereotactic body radiotherapy.

Authors:  Karthikeyan Nithiyanantham; Ganesh Kadirampatti Mani; Vikraman Subramani; Karrthick Karukkupalayam Palaniappan; Mohanraj Uthiran; Sennniandavar Vellengiri; Sambasivaselli Raju; Sanjay S Supe; Tejinder Kataria
Journal:  Rep Pract Oncol Radiother       Date:  2014-04-16

Review 7.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

8.  Analyzing the performance of ArcCHECK diode array detector for VMAT plan.

Authors:  Rajesh Thiyagarajan; Arunai Nambiraj; Sujit Nath Sinha; Girigesh Yadav; Ashok Kumar; Vikraman Subramani
Journal:  Rep Pract Oncol Radiother       Date:  2015-12-02

9.  Automated volumetric modulated Arc therapy treatment planning for stage III lung cancer: how does it compare with intensity-modulated radio therapy?

Authors:  Enzhuo M Quan; Joe Y Chang; Zhongxing Liao; Tingyi Xia; Zhiyong Yuan; Hui Liu; Xiaoqiang Li; Cody A Wages; Radhe Mohan; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-09-01       Impact factor: 7.038

10.  Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment.

Authors:  Barbara Dobler; Karin Weidner; Oliver Koelbl
Journal:  Radiat Oncol       Date:  2010-10-25       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.