Literature DB >> 20098635

SPECT Imaging of Teboroxime during Myocardial Blood Flow Changes.

E V R Di Bella1, H S Khare, D J Kadrmas, G T Gullberg.   

Abstract

Kinetic parameters and static images from dynamic SPECT imaging of (99m)Tc-teboroxime have been shown to reflect blood flow in dogs and in humans at rest and during adenosine stress. When compartment modeling is used, steady-state physiological conditions are assumed. With standard adenosine stress protocols, imaging of teboroxime would likely involve significant changes in flow, even if performed only for five minutes. These flow changes may significantly bias the kinetic parameter estimates. On the other hand, when static imaging is performed, large flow changes during acquisition may improve contrast between normal and occluded regions. Computer simulations were performed to determine the effect of changing flows on kinetic parameter estimation and on static (average tissue uptake) images. Two canine studies were also performed in which adenosine was given with a standard protocol, and then imaging was repeated with adenosine infusion held constant. The simulations predicted biases on the order of 7% for kinetic washin parameter estimation and 18% for the washout parameter. Contrast for static studies was found to depend critically on the time-activity behavior of the distribution as well as on the stress protocol. The differences in washin contrast from the standard and continous adenosine dog studies was slightly larger than predicted from the simulations. Optimal imaging of teboroxime with adenosine using compartment modeling will require non-standard adenosine stress protocols, although sub-optimal imaging may still be useful clinically.

Entities:  

Year:  2000        PMID: 20098635      PMCID: PMC2809426          DOI: 10.1109/23.856535

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  8 in total

1.  Experimental verification of technetium 99m-labeled teboroxime kinetic parameters in the myocardium with dynamic single-photon emission computed tomography: reproducibility, correlation to flow, and susceptibility to extravascular contamination.

Authors:  A M Smith; G T Gullberg; P E Christian
Journal:  J Nucl Cardiol       Date:  1996 Mar-Apr       Impact factor: 5.952

2.  Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow.

Authors:  R E Stewart; M Schwaiger; G D Hutchins; P C Chiao; K P Gallagher; N Nguyen; N A Petry; W L Rogers
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

3.  Effects of adenosine on human coronary arterial circulation.

Authors:  R F Wilson; K Wyche; B V Christensen; S Zimmer; D D Laxson
Journal:  Circulation       Date:  1990-11       Impact factor: 29.690

4.  Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: comparison with static thallium-201 in a canine model.

Authors:  E V Di Bella; S G Ross; D J Kadrmas; H S Khare; P E Christian; S McJames; A G Gullberg
Journal:  Invest Radiol       Date:  2001-03       Impact factor: 6.016

5.  Compartmental analysis of technetium-99m-teboroxime kinetics employing fast dynamic SPECT at rest and stress.

Authors:  P C Chiao; E P Ficaro; F Dayanikli; W L Rogers; M Schwaiger
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

6.  Measurement of myocardial blood flow using a co-injection technique for technetium-99m-teboroxime, technetium-96-sestamibi and thallium-201.

Authors:  R J Di Rocco; W L Rumsey; B L Kuczynski; K E Linder; J P Pirro; R K Narra; A D Nunn
Journal:  J Nucl Med       Date:  1992-06       Impact factor: 10.057

7.  The relationship between myocardial retention of technetium-99m teboroxime and myocardial blood flow.

Authors:  R Beanlands; O Muzik; N Nguyen; N Petry; M Schwaiger
Journal:  J Am Coll Cardiol       Date:  1992-09       Impact factor: 24.094

8.  Myocardial technetium-99m-teboroxime uptake during adenosine-induced hyperemia in dogs with either a critical or mild coronary stenosis: comparison to thallium-201 and regional blood flow.

Authors:  D K Glover; M Ruiz; E E Bergmann; J P Simanis; W H Smith; D D Watson; G A Beller
Journal:  J Nucl Med       Date:  1995-03       Impact factor: 10.057

  8 in total
  2 in total

1.  Simultaneous assessment of cardiac perfusion and function using 5-dimensional imaging with Tc-99m teboroxime.

Authors:  Bing Feng; P Hendrik Pretorius; Troy H Farncombe; Seth T Dahlberg; Manoj V Narayanan; Miles N Wernick; Anna M Celler; Jeffrey A Leppo; Michael A King
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

2.  Static Versus Dynamic Teboroxime Myocardial Perfusion SPECT in Canines.

Authors:  D J Kadrmas; E V R Di Bella; H S Khare; P E Christian; G T Gullberg
Journal:  IEEE Trans Nucl Sci       Date:  2000-06-01       Impact factor: 1.679

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.