Literature DB >> 20096617

Accuracy of real-time MR temperature mapping in the brain: a comparison of fast sequences.

A Kickhefel1, Jörg Roland, Clifford Weiss, Fritz Schick.   

Abstract

PURPOSE: To compare magnetic resonance (MR) thermometry based on the proton resonance frequency (PRF) method using a single shot echoplanar imaging (ss EPI) sequence to both of the standard sequences, gradient echo (GRE) and segmented echoplanar imaging (seg EPI) in the in vivo human brain, at 1.5T and 3T.
MATERIAL AND METHODS: Repetitive MR thermometry was performed on the brain of six volunteers using GRE, seg EPI, and ss EPI sequences on whole-body 1.5T and 3T clinical systems using comparable acquisition parameters. Phase stability and temperature data precision in the human head were determined over 12 min for the three sequences at both field strengths. An ex-vivo swine skeletal muscle model was used to evaluate temperature accuracy of the ss EPI sequence during heating by high intensity focused ultrasound (HIFU).
RESULTS: In-vivo examinations of brain revealed an average temperature precision of 0.37 °C/0.39 °C/0.16 °C at 3T for the GRE/seg EPI/ss EPI sequences. At 1.5T, a precision of 0.58 °C/0.63 °C/0.21 °C was achieved. In the ex-vivo swine model, a strong correlation of temperature data derived using ss EPI and GRE sequences was found with a temperature deviation <1 °C.
CONCLUSION: The ss EPI sequence was the fastest and the most precise sequence for MR thermometry, with significantly higher accuracy compared to GRE.
Copyright © 2009 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20096617     DOI: 10.1016/j.ejmp.2009.11.006

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  26 in total

1.  The influence of Nd:YAG laser irradiation on Fluoroptic® temperature measurement: an experimental evaluation.

Authors:  Frank Hübner; Babak Bazrafshan; Jörg Roland; Antje Kickhefel; Thomas Josef Vogl
Journal:  Lasers Med Sci       Date:  2012-04-04       Impact factor: 3.161

2.  Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array.

Authors:  A Payne; R Merrill; E Minalga; U Vyas; J de Bever; N Todd; R Hadley; E Dumont; L Neumayer; D Christensen; R Roemer; D Parker
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

3.  Experimental validation of a high-resolution diffuse optical imaging modality: photomagnetic imaging.

Authors:  Farouk Nouizi; Alex Luk; Dave Thayer; Yuting Lin; Seunghoon Ha; Gultekin Gulsen
Journal:  J Biomed Opt       Date:  2016-01       Impact factor: 3.170

4.  Fast PRF-based MR thermometry using double-echo EPI: in vivo comparison in a clinical hyperthermia setting.

Authors:  Tetiana Dadakova; Johanna Gellermann; Otilia Voigt; Jan Gerrit Korvink; John Matthew Pavlina; Jürgen Hennig; Michael Bock
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

5.  Model predictive filtering MR thermometry: Effects of model inaccuracies, k-space reduction factor, and temperature increase rate.

Authors:  Henrik Odéen; Nick Todd; Christopher Dillon; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-02-25       Impact factor: 4.668

6.  Laser-induced photo-thermal magnetic imaging.

Authors:  David A Thayer; Yuting Lin; Alex Luk; Gultekin Gulsen
Journal:  Appl Phys Lett       Date:  2012-08-23       Impact factor: 3.791

7.  Temperature imaging of laser-induced thermotherapy (LITT) by MRI: evaluation of different sequences in phantom.

Authors:  Babak Bazrafshan; Frank Hübner; Parviz Farshid; Renate Hammerstingl; Jijo Paul; Vitali Vogel; Werner Mäntele; Thomas J Vogl
Journal:  Lasers Med Sci       Date:  2013-03-28       Impact factor: 3.161

8.  Alleviating artifacts in 1H MRI thermometry by single scan spatiotemporal encoding.

Authors:  Rita Schmidt; Lucio Frydman
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310

9.  An accelerated photo-magnetic imaging reconstruction algorithm based on an analytical forward solution and a fast Jacobian assembly method.

Authors:  F Nouizi; H Erkol; A Luk; M Marks; M B Unlu; G Gulsen
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

10.  Lateral ventricular cerebrospinal fluid diffusivity as a potential neuroimaging marker of brain temperature in multiple sclerosis: a hypothesis and implications.

Authors:  Khader M Hasan; John A Lincoln; Flavia M Nelson; Jerry S Wolinsky; Ponnada A Narayana
Journal:  Magn Reson Imaging       Date:  2014-12-05       Impact factor: 2.546

View more