Literature DB >> 20096524

Quantitative analysis of spatial distortions of diffusion techniques at 3T.

Duan Xu1, Michael C Lee, Julio Carballido-Gamio, Matthew Barkovich, Sharmila Majumdar, Daniel B Vigneron, Sarah J Nelson.   

Abstract

Diffusion has been widely adopted in the clinical setting to study the microstructural tissue changes in conjunction with anatomic imaging and metabolic imaging to offer insights on the status of the tissue injury or lesion. However, geometric distortions caused by magnetic susceptibility effects, eddy currents and gradient imperfections greatly affect the clinical utility of the diffusion images. Several diffusion methods have been proposed in the recent years to obtain diffusion parameters with increased accuracy. In most cases, the comparisons to the clinical standard echo-planar imaging (EPI) diffusion are done visually without quantitative measurements. In this study, we present three simple, complementary quantitative methods of nonrigid image registration and shape analyses for evaluating spatial distortions on magnetic resonance images with application in comparing single-shot fast spin-echo (SSFSE) and EPI based diffusion measurements. These methods have confirmed the SSFSE based diffusion method is less distorted than the EPI based one, which is generally accepted through visual inspection. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20096524      PMCID: PMC2842007          DOI: 10.1016/j.mri.2009.11.008

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  16 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

3.  Navigator motion correction of diffusion weighted 3D SSFP imaging.

Authors:  E Bosak; P R Harvey
Journal:  MAGMA       Date:  2001-05       Impact factor: 2.310

4.  Single-shot fast spin-echo diffusion tensor imaging of the brain and spine with head and phased array coils at 1.5 T and 3.0 T.

Authors:  Duan Xu; Roland G Henry; Pratik Mukherjee; Lucas Carvajal; Steven P Miller; A James Barkovich; Daniel B Vigneron
Journal:  Magn Reson Imaging       Date:  2004-07       Impact factor: 2.546

5.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

Review 6.  The role of diffusion tensor imaging in the evaluation of ischemic brain injury - a review.

Authors:  Christopher H Sotak
Journal:  NMR Biomed       Date:  2002 Nov-Dec       Impact factor: 4.044

7.  Estimating tissue deformation between functional images induced by intracranial electrode implantation using anatomical MRI.

Authors:  C Studholme; E Novotny; I G Zubal; J S Duncan
Journal:  Neuroimage       Date:  2001-04       Impact factor: 6.556

Review 8.  Multiparametric magnetic resonance imaging in prostate cancer: present and future.

Authors:  John Kurhanewicz; Daniel Vigneron; Peter Carroll; Fergus Coakley
Journal:  Curr Opin Urol       Date:  2008-01       Impact factor: 2.309

9.  Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI.

Authors:  G K Rohde; A S Barnett; P J Basser; S Marenco; C Pierpaoli
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

Review 10.  Fast robust automated brain extraction.

Authors:  Stephen M Smith
Journal:  Hum Brain Mapp       Date:  2002-11       Impact factor: 5.038

View more
  2 in total

1.  The impact of susceptibility correction on diffusion metrics in adolescents.

Authors:  Katri Lahti; Riitta Parkkola; Päivi Jääsaari; Leena Haataja; Virva Saunavaara
Journal:  Pediatr Radiol       Date:  2021-04-24

2.  Development of a hybrid magnetic resonance and ultrasound imaging system.

Authors:  Victoria Sherwood; John Civale; Ian Rivens; David J Collins; Martin O Leach; Gail R ter Haar
Journal:  Biomed Res Int       Date:  2014-08-07       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.