Improved dose regimen in pediatric PET.

Roberto Accorsi1, Joel S Karp, Suleman Surti.   

Abstract

UNLABELLED: PET image quality depends strongly on patient weight and habitus, decreasing for increasing weight and body mass index. Common adult injection rules prescribe either a dose proportional to weight or a fixed dose. In light patients, image quality may improve for decreasing weight more than by inverse proportion. If better quality than in average-adult studies does not justify the associated dose burden, attractive options are to reduce scan time, reduce dose, or any combination of the 2. The objective of this study was to determine quantitative injection rules for pediatric PET allowing clinical implementation of these trade-offs.
METHODS: Literature methods combining phantom with clinical data were followed to derive patient-specific noise-equivalent count rate density (NECRD) curves as a function of injected dose. From these, it was possible to estimate retrospectively for each patient the scan time that would have been sufficient for the same NECRD as in a 70-kg reference adult; the reduced dose sufficient for constant NECRD and scan time; and a general relationship among scan time, dose, and NECRD. Correlation to the patient statistic giving highest correlation, which was found to be weight, provided rules applicable prospectively. Data from 73 patients (weight, 11.5-91.4 kg; mean, 45.4 kg) were acquired and analyzed.
RESULTS: Following the clinical injection rule, which was proportional to weight, the NECRD increased linearly with decreasing weight. The expression exp[0.019 x (weight [kg] - 70)] for the time reduction possible with the current dose at constant NECRD correlated well with data (R(2) = 0.86). The dose (in MBq) necessary for constant NECRD that should be injected 60 min before imaging is predicted well by 14.8 x exp[0.046 x weight (kg)] (R(2) = 0.88) with the current scan time. A more complex expression to convert NECRD in whole or part to both dose and time savings was also derived. Comparison to common pediatric injection rules showed reasonable agreement with Clark's rule, albeit not at all weights.
CONCLUSION: Results suggest that pediatric PET of constant image quality (in an NECRD sense) can be performed with time or dose savings, up to 50% for the lightest patients (10-20 kg).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20080887     DOI: 10.2967/jnumed.109.066332

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

1.  An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid.

Authors:  George Sgouros; Eric C Frey; Wesley E Bolch; Michael B Wayson; Andres F Abadia; S Ted Treves
Journal:  J Nucl Med       Date:  2011-12       Impact factor: 10.057

2.  Estimated cumulative radiation dose from PET/CT in children with malignancies.

Authors:  Michael J Gelfand; Susan E Sharp; S Ted Treves; Frederic H Fahey; Marguerite T Parisi; Adam M Alessio
Journal:  Pediatr Radiol       Date:  2010-08-13

3.  Image quality and lesion detectability in low-dose pediatric 18F-FDG scans using total-body PET/CT.

Authors:  Yu-Mo Zhao; Ying-He Li; Tao Chen; Wei-Guang Zhang; Lin-Hao Wang; Jiatai Feng; Chenwei Li; Xu Zhang; Wei Fan; Ying-Ying Hu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-03-18       Impact factor: 9.236

4.  Paediatric radiopharmaceutical administration: harmonization of the 2007 EANM paediatric dosage card (version 1.5.2008) and the 2010 North American consensus guidelines.

Authors:  Michael Lassmann; S Ted Treves
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-06       Impact factor: 9.236

5.  Evaluation of pediatric malignancies using total-body PET/CT with half-dose [18F]-FDG.

Authors:  Wanqi Chen; Lei Liu; Yinghe Li; Shatong Li; Zhijian Li; Weiguang Zhang; Xu Zhang; Runze Wu; Debin Hu; Hongyan Sun; Yun Zhou; Wei Fan; Yumo Zhao; Yizhuo Zhang; Yingying Hu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-05       Impact factor: 10.057

Review 6.  Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects.

Authors:  Nicolas A Karakatsanis; Eleni Fokou; Charalampos Tsoumpas
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

7.  A dedicated paediatric [18F]FDG PET/CT dosage regimen.

Authors:  Christina P W Cox; Daniëlle M E van Assema; Frederik A Verburg; Tessa Brabander; Mark Konijnenberg; Marcel Segbers
Journal:  EJNMMI Res       Date:  2021-07-19       Impact factor: 3.138

8.  Investigating Low-Dose Image Quality in Whole-Body Pediatric 18F-FDG Scans Using Time-of-Flight PET/MRI.

Authors:  Jeffrey P Schmall; Suleman Surti; Hansel J Otero; Sabah Servaes; Joel S Karp; Lisa J States
Journal:  J Nucl Med       Date:  2020-06-01       Impact factor: 11.082

9.  Optimized dose regimen for whole-body FDG-PET imaging.

Authors:  Eleonore H de Groot; Nieky Post; Ronald Boellaard; Nils Rl Wagenaar; Antoon Tm Willemsen; Jorn A van Dalen
Journal:  EJNMMI Res       Date:  2013-08-12       Impact factor: 3.138

10.  Select the optimized effective dose to reduce nuclear radiations in pediatric nuclear medicine.

Authors:  Ying Bai; Dali Wang
Journal:  World J Nucl Med       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.