Uwe Walschus1, Andreas Hoene, Maciej Patrzyk, Birgit Finke, Martin Polak, Silke Lucke, Barbara Nebe, Karsten Schroeder, Andreas Podbielski, Lutz Wilhelm, Michael Schlosser.
Abstract
Surface modification of Titanium (Ti) by low-temperature plasma influences cell-material interactions. Therefore, this study aimed at examining serum cytokine levels and associations after intramuscular implantation (n = 8 rats/group) of Ti-plates with Plasma Polymerized Allyl Amine (Ti-PPAAm), Plasma Polymerized Acrylic Acid (Ti-PPAAc), and without such layers (Ti-Controls). Pro-inflammatory (IL-2, IFNγ, IL-6) and anti-inflammatory (IL-4, IL-10, IL-13) cytokines were measured weekly for 56 days. Ti-PPAAm caused increased IL-2 (d7-14, d35), increased IFNγ (d35) and decreased IL-10 (d35, d49-56). Ti-PPAAc induced divergent anti-inflammatory cytokine changes with increased IL-4 (d28-56) and decreased IL-10 (d42-56). Ti-Controls elicited increased IL-2 (d42) and IFNγ (d35-42, d56). IL-6 was not detected and IL-13 only in three samples, thus they do not influence the response against these Ti implants. Correlation analysis revealed surface-dependent associations between cytokines indicating the involvement of different inflammatory cell populations. Concluding, different plasma modifications induce specific serum cytokine profiles and associations indicating distinct inflammatory responses.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22402792 DOI: 10.1007/s10856-012-4600-z
Source DB: PubMed Journal: J Mater Sci Mater Med ISSN: 0957-4530 Impact factor: 3.896