Literature DB >> 20070279

One year follow-up of contrast sensitivity following conventional laser in situ keratomileusis and laser epithelial keratomileusis.

Deirdre Townley1, Caitriona Kirwan, Michael O'Keefe.   

Abstract

PURPOSE: To determine the effect of conventional laser in situ keratomileusis (LASIK) and laser epithelial keratomileusis (LASEK) for myopia on contrast sensitivity (CS) using the Pelli-Robson and Vector Vision CSV-1000E CS tests.
METHODS: A prospective, comparative study was conducted on 36 eyes of 36 patients with myopia undergoing LASIK (18 eyes) and LASEK (18 eyes). Surgery was performed using the Technolas 217z laser (Bausch & Lomb). CS was recorded preoperatively and at 3, 6 and 12 months postoperatively.
RESULTS: No statistically significant difference was found in LogMAR uncorrected visual acuity post-LASIK (-0.02 ± 0.16) and LASEK (-0.04 ± 0.14). Using the Pelli-Robson, CS was significantly lower in the LASIK group 3 and 6 months postoperatively. No significant postoperative reduction in CS was observed in either treatment group. Using the CSV-1000E test, CS was significantly reduced post-LASIK at 3 (p = 0.05) and 6 (p = 0.05) cycles/degree under photopic conditions. No significant postoperative change occurred in the LASEK group under photopic or scotopic conditions. There was no significant difference in postoperative CS between the LASIK and LASEK groups at 3, 6, 12 or 18 cycles/degree using the CSV-1000E test.
CONCLUSION: One year postoperatively, there was no difference in CS between both treatment groups using the Pelli-Robson and CSV-1000E tests. CS was reduced postoperatively in the LASIK group at the lower spatial frequencies under photopic conditions. No postoperative change was detected in CS following LASIK or LASEK using the Pelli-Robson test.
© 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

Entities:  

Mesh:

Year:  2010        PMID: 20070279     DOI: 10.1111/j.1755-3768.2009.01822.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  4 in total

1.  Visual performance after conventional LASIK and wavefront-guided LASIK with iris-registration: results at 1 year.

Authors:  Jing Zhang; Yue-Hua Zhou; Rui Li; Lei Tian
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

2.  Comparison of contrast sensitivity based on the surgical results for intermittent exotropia.

Authors:  Hae Rang Kim; Soo Jung Lee
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

3.  Comparison of postoperative visual quality after SMILE and LASEK for high myopia: A 1-year outcome.

Authors:  Xiaoyu Zhu; Leilei Zou; Manrong Yu; Chen Qiu; Minjie Chen; Jinhui Dai
Journal:  PLoS One       Date:  2017-08-03       Impact factor: 3.240

4.  Reversal of Myopic Correction for Patients Intolerant to LASIK.

Authors:  Amr A Gab-Alla
Journal:  J Ophthalmol       Date:  2021-12-15       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.