Literature DB >> 20058470

Reduction and stabilization of lumbar and thoracolumbar spine fractures with Louis' plates and internal fixator: a comparative study.

P Zangger1, T Pache.   

Abstract

In this retrospective study, 28 patients who presented isolated fractures from T11 to L4 were surgically treated using a posterior approach. The fractures were reduced and stabilized in half of the cases with Louis' plates and in the other half with an internal fixator. Twelve patients had partial neurological deficits on admission. They were reviewed after a mean period of 24 months from time of injury, and 10 months after implant removal. The kyphosis of the fractured vertebral body was measured, and showed a mean value of 18 degrees before surgery and 10.3 degrees at the last visit. The regional statics of the spine were also studied. The residual mobility of the fixated and neighbouring spinal units was assessed, comparing "long" segment fixation (plates) with "sh ort" segment fixation (internal fixator). The residual mobility of the adjacent, non-fixed segments was significantly better when the internal fixator had been used than with the Louis' plates. Of the 12 patients with neurological involvement, 11 had increased their Frankel score by one grade. Results were evaluated by clinical parameters (pain, neurological deficit, occupational disability); scores were as follows: 32% good, 57% satisfactory and 11% poor. There was no significant difference in clinical score between the two treatment modalities.

Entities:  

Mesh:

Year:  1993        PMID: 20058470     DOI: 10.1007/bf00301415

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  10 in total

1.  Vertebral motion measured using biplanar radiography before and after Harrington rod removal for unstable thoracolumbar fractures of the spine.

Authors:  C A Dodd; C M Fergusson; M J Pearcy; G R Houghton
Journal:  Spine (Phila Pa 1976)       Date:  1986-06       Impact factor: 3.468

2.  Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system. Indications, techniques, and first results of treatment.

Authors:  M Aebi; C Etter; T Kehl; J Thalgott
Journal:  Spine (Phila Pa 1976)       Date:  1987 Jul-Aug       Impact factor: 3.468

3.  The value of postural reduction in the initial management of closed injuries of the spine with paraplegia and tetraplegia. I.

Authors:  H L Frankel; D O Hancock; G Hyslop; J Melzak; L S Michaelis; G H Ungar; J D Vernon; J J Walsh
Journal:  Paraplegia       Date:  1969-11

4.  Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine.

Authors:  A D Steffee; R S Biscup; D J Sitkowski
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

5.  Stabilization of the lower thoracic and lumbar spine with external skeletal fixation.

Authors:  F P Magerl
Journal:  Clin Orthop Relat Res       Date:  1984-10       Impact factor: 4.176

6.  Anterior fixation for fractures of the thoracic and lumbar spine with or without neurologic involvement.

Authors:  J P Kostuik
Journal:  Clin Orthop Relat Res       Date:  1984-10       Impact factor: 4.176

7.  The fixateur interne in the reduction and stabilization of thoracolumbar spine fractures in patients with neurologic deficit.

Authors:  R W Lindsey; W Dick
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

8.  The three column spine and its significance in the classification of acute thoracolumbar spinal injuries.

Authors:  F Denis
Journal:  Spine (Phila Pa 1976)       Date:  1983 Nov-Dec       Impact factor: 3.468

9.  A new device for internal fixation of thoracolumbar and lumbar spine fractures: the 'fixateur interne'.

Authors:  W Dick; P Kluger; F Magerl; O Woersdörfer; G Zäch
Journal:  Paraplegia       Date:  1985-08

10.  Internal fixation of the lumbar spine with pedicle screw plating.

Authors:  R Roy-Camille; G Saillant; C Mazel
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.