Literature DB >> 20035922

Wavefront analysis, contrast sensitivity, and depth of focus after cataract surgery with aspherical intraocular lens implantation.

Marcony R Santhiago1, Marcelo V Netto, Jackson Barreto, Beatriz A F Gomes, Adriana Mukai, Ana Paula Calil Guermandi, Newton Kara-Junior.   

Abstract

PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus.
DESIGN: Double-blinded, randomized, prospective study.
METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus.
RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at 1 and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups.
CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20035922     DOI: 10.1016/j.ajo.2009.09.019

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.

Authors:  Xian-Hui Gong; Qin-Xiang Zheng; Na Wang; Ding Chen; Juan Zhao; Jin Li; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

2.  Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics.

Authors:  Mohammad Taher Rajabi; Sara Korouji; Mahgol Farjadnia; Mohammad Naderan; Mohammad Bagher Rajabi; Bahram Khosravi; Seyed Mehdi Tabatabaie
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

3.  Clinical study of customized aspherical intraocular lens implants.

Authors:  Lie-Xi Jia; Zhao-Hui Li
Journal:  Int J Ophthalmol       Date:  2014-10-18       Impact factor: 1.779

4.  Contrast sensitivity and spherical aberration in eyes implanted with AcrySof IQ and AcrySof Natural intraocular lens: the results of a meta-analysis.

Authors:  Jianping Liu; Jiangyue Zhao; Liwei Ma; Guangcong Liu; Di Wu; Jinsong Zhang
Journal:  PLoS One       Date:  2013-10-18       Impact factor: 3.240

5.  Normal range of cambridge low contrast test; a population based study.

Authors:  Hadi Ostadimoghaddam; Akbar Fotouhi; Hassan Hashemi; Abbas Ali Yekta; Javad Heravian; Tahereh Abdolahinia; Reza Norouzi Rad; Soheila Asgari; Mehdi Khabazkhoob
Journal:  J Ophthalmic Vis Res       Date:  2014-01

6.  A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.

Authors:  Hamid Gharaee; Masoud Zabihifard; Alireza Eslampour; Samira Hassanzadeh; Masoud Shafiee
Journal:  J Curr Ophthalmol       Date:  2016-03-28

7.  Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista).

Authors:  Mark Packer; Luther Fry; Kevin T Lavery; Robert Lehmann; James McDonald; Louis Nichamin; Brian Bearie; Jon Hayashida; Griffith E Altmann; Omid Khodai
Journal:  Clin Ophthalmol       Date:  2013-09-24

8.  Safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (enVista®) - results of a European and Asian-Pacific study.

Authors:  Peter Heiner; Edoardo Ligabue; Alex Fan; Dennis Lam
Journal:  Clin Ophthalmol       Date:  2014-03-27

Review 9.  Clinical applications of wavefront refraction.

Authors:  Adrian S Bruce; Louis J Catania
Journal:  Optom Vis Sci       Date:  2014-10       Impact factor: 1.973

10.  Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses.

Authors:  Michael Lasta; Kata Miháltz; Illés Kovács; Pia Veronika Vécsei-Marlovits
Journal:  J Ophthalmol       Date:  2017-08-16       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.