Literature DB >> 20031985

The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics.

Chun Chen1, Bin Zhao, Weilin Cui, Lei Dong, Na An, Xiangying Ouyang.   

Abstract

Dental healthcare workers (DHCWs) are at high risk of occupational exposure to droplets and aerosol particles emitted from patients' mouths during treatment. We evaluated the effectiveness of an air cleaner in reducing droplet and aerosol contamination by positioning the device in four different locations in an actual dental clinic. We applied computational fluid dynamics (CFD) methods to solve the governing equations of airflow, energy and dispersion of different-sized airborne droplets/aerosol particles. In a dental clinic, we measured the supply air velocity and temperature of the ventilation system, the airflow rate and the particle removal efficiency of the air cleaner to determine the boundary conditions for the CFD simulations. Our results indicate that use of an air cleaner in a dental clinic may be an effective method for reducing DHCWs' exposure to airborne droplets and aerosol particles. Further, we found that the probability of droplet/aerosol particle removal and the direction of airflow from the cleaner are both important control measures for droplet and aerosol contamination in a dental clinic. Thus, the distance between the air cleaner and droplet/aerosol particle source as well as the relative location of the air cleaner to both the source and the DHCW are important considerations for reducing DHCWs' exposure to droplets/aerosol particles emitted from the patient's mouth during treatments.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20031985      PMCID: PMC2880082          DOI: 10.1098/rsif.2009.0516

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  24 in total

1.  Microbial aerosols in general dental practice.

Authors:  A M Bennett; M R Fulford; J T Walker; D J Bradshaw; M V Martin; P D Marsh
Journal:  Br Dent J       Date:  2000-12-23       Impact factor: 1.626

2.  Quantitative microbial monitoring in a dental office.

Authors:  L Cellini; E Di Campli; M Di Candia; G Chiavaroli
Journal:  Public Health       Date:  2001-07       Impact factor: 2.427

3.  Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms.

Authors:  William J Riley; Thomas E McKone; Alvin C K Lai; William W Nazaroff
Journal:  Environ Sci Technol       Date:  2002-01-15       Impact factor: 9.028

4.  Microbial aerosol contamination of dental healthcare workers' faces and other surfaces in dental practice.

Authors:  Emilia Prospero; Sandra Savini; Isidoro Annino
Journal:  Infect Control Hosp Epidemiol       Date:  2003-02       Impact factor: 3.254

5.  Computational fluid dynamics and room air movement.

Authors:  P V Nielsen
Journal:  Indoor Air       Date:  2004       Impact factor: 5.770

6.  Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation.

Authors:  C Chen; B Zhao
Journal:  Indoor Air       Date:  2009-09-24       Impact factor: 5.770

7.  Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.

Authors:  Y Li; X Huang; I T S Yu; T W Wong; H Qian
Journal:  Indoor Air       Date:  2005-04       Impact factor: 5.770

8.  Infectious diseases and the dental office.

Authors:  P L Anders; A J Drinnan; T J Thines
Journal:  N Y State Dent J       Date:  1998-04

9.  The numbers and the sites of origin of the droplets expelled during expiratory activities.

Authors:  J P DUGUID
Journal:  Edinb Med J       Date:  1945-11

10.  Toward understanding the risk of secondary airborne infection: emission of respirable pathogens.

Authors:  Mark Nicas; William W Nazaroff; Alan Hubbard
Journal:  J Occup Environ Hyg       Date:  2005-03       Impact factor: 2.155

View more
  21 in total

1.  Role of two-way airflow owing to temperature difference in severe acute respiratory syndrome transmission: revisiting the largest nosocomial severe acute respiratory syndrome outbreak in Hong Kong.

Authors:  Chun Chen; Bin Zhao; Xudong Yang; Yuguo Li
Journal:  J R Soc Interface       Date:  2010-11-10       Impact factor: 4.118

2.  Effectiveness of facemasks to reduce exposure hazards for airborne infections among general populations.

Authors:  A C K Lai; C K M Poon; A C T Cheung
Journal:  J R Soc Interface       Date:  2011-09-21       Impact factor: 4.118

3.  Emergency management in dental clinic during the Coronavirus Disease 2019 (COVID-19) epidemic in Beijing.

Authors:  Chao Wang; Li Miao; Zhigang Wang; Yanjie Xiong; Yang Jiao; Hongchen Liu
Journal:  Int Dent J       Date:  2020-10-07       Impact factor: 2.512

Review 4.  A rapid review of the use of face mask in preventing the spread of COVID-19.

Authors:  Mary Abboah-Offei; Yakubu Salifu; Bisi Adewale; Jonathan Bayuo; Rasheed Ofosu-Poku; Edwina Beryl Addo Opare-Lokko
Journal:  Int J Nurs Stud Adv       Date:  2020-12-05

5.  Optimization of nebulized delivery of linezolid, daptomycin, and vancomycin aerosol.

Authors:  Paul Zarogoulidis; Ioannis Kioumis; Sofia Lampaki; John Organtzis; Konstantinos Porpodis; Dionysios Spyratos; Georgia Pitsiou; Dimitris Petridis; Athanasia Pataka; Haidong Huang; Qiang Li; Lonny Yarmus; Wolfgang Hohenforst-Schmidt; Nikolaos Pezirkianidis; Konstantinos Zarogoulidis
Journal:  Drug Des Devel Ther       Date:  2014-08-12       Impact factor: 4.162

6.  Modelling levels of nitrous oxide exposure for healthcare professionals during EMONO usage.

Authors:  Marine Pichelin; Catherine Billoet; Georges Caillibotte
Journal:  Ann Occup Environ Med       Date:  2016-07-07

7.  Nursing strategies for COVID-19 prevention and control in a selected dental clinic.

Authors:  Jiali Zheng; Xiaojun Ni; Weijun Yuan; Lili Hou
Journal:  Int Nurs Rev       Date:  2021-06       Impact factor: 2.871

8.  Pandemic preparedness of dentists against coronavirus disease: A Saudi Arabian experience.

Authors:  Khalifa S Al-Khalifa; Rasha AlSheikh; Abdullah S Al-Swuailem; Muneera S Alkhalifa; Mahmoud H Al-Johani; Saud A Al-Moumen; Zainab I Almomen
Journal:  PLoS One       Date:  2020-08-19       Impact factor: 3.240

9.  A hybrid model for investigating transient particle transport in enclosed environments.

Authors:  Chun Chen; Wei Liu; Fei Li; Chao-Hsin Lin; Junjie Liu; Jingjing Pei; Qingyan Chen
Journal:  Build Environ       Date:  2013-02-01       Impact factor: 6.456

10.  Role of air changes per hour (ACH) in possible transmission of airborne infections.

Authors:  Farhad Memarzadeh; Weiran Xu
Journal:  Build Simul       Date:  2011-12-22       Impact factor: 3.751

View more