Literature DB >> 20002792

Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation.

C Chen1, B Zhao.   

Abstract

This study employs a numerical model to investigate the dispersion characteristics of human exhaled droplets in ventilation rooms. The numerical model is validated by two different experiments prior to the application for the studied cases. Some typical questions on studying dispersion of human exhaled droplets indoors are reviewed and numerical study using the normalized evaporation time and normalized gravitational sedimentation time was performed to obtain the answers. It was found that modeling the transient process from a droplet to a droplet nucleus due to evaporation can be neglected when the normalized evaporation time is <0.051. When the normalized gravitational sedimentation time is <0.005, the influence of ventilation rate could be neglected. However, the influence of ventilation pattern and initial exhaled velocity on the exhaled droplets dispersion is dominant as the airflow decides the droplets dispersion significantly. Besides, the influence of temperature and relative humidity on the dispersion of droplets can be neglected for the droplet with initial diameter <200 microm; while droplet nuclei size plays an important role only for the droplets with initial diameter within the range of 10 microm-100 microm. Practical Implications Dispersion of human exhaled droplets indoor is a key issue when evaluating human exposure to infectious droplets. Results from detailed numerical studies in this study reveal how the evaporation of droplets, ventilation rate, airflow pattern, initial exhaled velocity, and particle component decide the droplet dispersion indoor. The detailed analysis of these main influencing factors on droplet dispersion in ventilation rooms may help to guide (1) the selection of numerical approach, e.g., if the transient process from a droplet to a droplet nucleus due to evaporation should be incorporated to study droplet dispersion, and (2) the selection of ventilation system to minimize the spread of pathogen-laden droplets in an indoor environment.

Entities:  

Mesh:

Year:  2009        PMID: 20002792     DOI: 10.1111/j.1600-0668.2009.00626.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  38 in total

1.  Role of two-way airflow owing to temperature difference in severe acute respiratory syndrome transmission: revisiting the largest nosocomial severe acute respiratory syndrome outbreak in Hong Kong.

Authors:  Chun Chen; Bin Zhao; Xudong Yang; Yuguo Li
Journal:  J R Soc Interface       Date:  2010-11-10       Impact factor: 4.118

2.  Modeling of occupational exposure to accidentally released manufactured nanomaterials in a production facility and calculation of internal doses by inhalation.

Authors:  Marika Pilou; Celina Vaquero-Moralejo; María Jaén; Jesús Lopez De Ipiña Peña; Panagiotis Neofytou; Christos Housiadas
Journal:  Int J Occup Environ Health       Date:  2016-09-27

3.  Transmission of pathogen-laden expiratory droplets in a coach bus.

Authors:  Xia Yang; Cuiyun Ou; Hongyu Yang; Li Liu; Tie Song; Min Kang; Hualiang Lin; Jian Hang
Journal:  J Hazard Mater       Date:  2020-04-12       Impact factor: 10.588

4.  Molecular Communications in Viral Infections Research: Modeling, Experimental Data, and Future Directions.

Authors:  Michael Taynnan Barros; Mladen Veletic; Masamitsu Kanada; Massimiliano Pierobon; Seppo Vainio; Ilangko Balasingham; Sasitharan Balasubramaniam
Journal:  IEEE Trans Mol Biol Multiscale Commun       Date:  2021-04-15

5.  Comparison between fully resolved and time-averaged simulations of particle cloud dispersion produced by a violent expiratory event.

Authors:  Akim Lavrinenko; Alexandre Fabregat; Jordi Pallares
Journal:  Acta Mech Sin       Date:  2022-04-25       Impact factor: 2.910

6.  The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics.

Authors:  Chun Chen; Bin Zhao; Weilin Cui; Lei Dong; Na An; Xiangying Ouyang
Journal:  J R Soc Interface       Date:  2009-12-23       Impact factor: 4.118

7.  Numerical evaluation of face masks for prevention of COVID-19 airborne transmission.

Authors:  Jiaxing Liu; Ming Hao; Shulei Chen; Yang Yang; Jian Li; Qi Mei; Xin Bian; Kun Liu
Journal:  Environ Sci Pollut Res Int       Date:  2022-02-09       Impact factor: 5.190

8.  Mitigating COVID-19 infection disease transmission in indoor environment using physical barriers.

Authors:  Chen Ren; Chang Xi; Junqi Wang; Zhuangbo Feng; Fuzhan Nasiri; Shi-Jie Cao; Fariborz Haghighat
Journal:  Sustain Cities Soc       Date:  2021-07-14       Impact factor: 7.587

9.  Novel measurement system for respiratory aerosols and droplets in indoor environments.

Authors:  Michael Lommel; Vera Froese; Moritz Sieber; Marvin Jentzsch; Tim Bierewirtz; Ümit Hasirci; Tim Rese; Josef Seefeldt; Sebastian Schimek; Ulrich Kertzscher; Christian Oliver Paschereit
Journal:  Indoor Air       Date:  2021-06-07       Impact factor: 6.554

10.  Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward.

Authors:  Xiangfei Kong; Chenli Guo; Zhang Lin; Shasha Duan; Junjie He; Yue Ren; Jianlin Ren
Journal:  Sustain Cities Soc       Date:  2021-06-17       Impact factor: 7.587

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.