Literature DB >> 15737151

Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.

Y Li1, X Huang, I T S Yu, T W Wong, H Qian.   

Abstract

UNLABELLED: Severe acute respiratory syndrome (SARS) is primarily transmitted by bio-aerosol droplets or direct personal contacts. This paper presents a detailed study of environmental evidence of possible airborne transmission in a hospital ward during the largest nosocomial SARS outbreak in Hong Kong in March 2003. Retrospective on-site inspections and measurements of the ventilation design and air distribution system were carried out on July 17, 2003. Limited on-site measurements of bio-aerosol dispersion were also carried out on July 22. Computational fluid dynamics simulations were performed to analyze the bio-aerosol dispersion in the hospital ward. We attempted to predict the air distribution during the time of measurement in July 2003 and the time of exposure in March 2003. The predicted bio-aerosol concentration distribution in the ward seemed to agree fairly well with the spatial infection pattern of SARS cases. Possible improvement to air distribution in the hospital ward was also considered. PRACTICAL IMPLICATIONS: Our study revealed the need for the development of improved ventilation and air-conditioning systems in an isolation ward or a general hospital ward for infectious respiratory diseases. The outbreak in Ward 8A, which was in a general hospital and could house nearly 40 patients, demonstrated the cross-infection risks of respiratory infectious diseases in hospitals if a potential highly infectious patient was not identified and isolated. Our example simulation, which extended the SARS Busters' design for an isolation room to Ward 8A, demonstrated that there was room for improvement to minimize cross-infection in large general hospital wards.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15737151     DOI: 10.1111/j.1600-0668.2004.00317.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  108 in total

1.  Role of two-way airflow owing to temperature difference in severe acute respiratory syndrome transmission: revisiting the largest nosocomial severe acute respiratory syndrome outbreak in Hong Kong.

Authors:  Chun Chen; Bin Zhao; Xudong Yang; Yuguo Li
Journal:  J R Soc Interface       Date:  2010-11-10       Impact factor: 4.118

2.  Characterizations of particle size distribution of the droplets exhaled by sneeze.

Authors:  Z Y Han; W G Weng; Q Y Huang
Journal:  J R Soc Interface       Date:  2013-09-11       Impact factor: 4.118

Review 3.  Methods for sampling of airborne viruses.

Authors:  Daniel Verreault; Sylvain Moineau; Caroline Duchaine
Journal:  Microbiol Mol Biol Rev       Date:  2008-09       Impact factor: 11.056

4.  Personalized ventilation as a control measure for airborne transmissible disease spread.

Authors:  Jovan Pantelic; Gin Nam Sze-To; Kwok Wai Tham; Christopher Y H Chao; Yong Chuan Mike Khoo
Journal:  J R Soc Interface       Date:  2009-10-07       Impact factor: 4.118

5.  Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards.

Authors:  Catherine J Noakes; P Andrew Sleigh
Journal:  J R Soc Interface       Date:  2009-10-07       Impact factor: 4.118

6.  Exhaled droplets due to talking and coughing.

Authors:  Xiaojian Xie; Yuguo Li; Hequan Sun; Li Liu
Journal:  J R Soc Interface       Date:  2009-10-07       Impact factor: 4.118

Review 7.  Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.

Authors:  Hua Qian; Xiaohong Zheng
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

8.  Centralized air-conditioning and transmission of novel coronavirus.

Authors:  Ruqaiyyah Siddiqui; Naveed Ahmed Khan
Journal:  Pathog Glob Health       Date:  2020-05-13       Impact factor: 2.894

9.  Hospital design for better infection control.

Authors:  Fatimah Lateef
Journal:  J Emerg Trauma Shock       Date:  2009-09

10.  A schlieren optical study of the human cough with and without wearing masks for aerosol infection control.

Authors:  Julian W Tang; Thomas J Liebner; Brent A Craven; Gary S Settles
Journal:  J R Soc Interface       Date:  2009-10-08       Impact factor: 4.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.