Literature DB >> 20027985

Pupil size, white-to-white corneal diameter, and anterior chamber depth in patients with myopia.

José F Alfonso1, Teresa Ferrer-Blasco, José M González-Méijome, M García-Manjarres, Sofia C Peixoto-de-Matos, Robert Montés-Micó.   

Abstract

PURPOSE: To evaluate anatomical parameters in a population of patients with myopia.
METHODS: Nine hundred sixty-four myopic eyes (-3.00 to -20.00 diopters [D] spherical equivalent refraction) were evaluated to measure mesopic and photopic pupil size with an infrared pupillometer; anterior chamber depth and white-to-white corneal diameter were obtained with Orbscan II (Bausch & Lomb). Correlation analysis was performed to evaluate the relationships among anatomical parameters of the anterior segment of the eye.
RESULTS: Average change in pupil size between mesopic and photopic conditions shows a uniform gap of 1.5 mm in patients aged 18 to 62 years with a slight insignificant trend to decrease with age. Photopic and mesopic pupil size were highly correlated (r=0.694, P<.001) and the difference between both measures was positively correlated with mesopic pupil size (r=0.207, P<.001) and inversely correlated with photopic pupil size (r=0.561, P<.001). Anterior chamber depth and white-to-white corneal diameter were positively correlated (r=0.389, P<.001). White-to-white corneal diameter and anterior chamber depth were not correlated with age (r=-0.096, P<.001) or anterior chamber depth (r=-0.183, P<.001-0.183) as a function of age.
CONCLUSIONS: Average difference between photopic and mesopic pupil size remained constant across the range of ages included in this cohort. A positive correlation was noted between anterior segment dimensions, and anterior chamber depth decreased with age. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2009        PMID: 20027985     DOI: 10.3928/1081597X-20091209-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  10 in total

1.  Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCT.

Authors:  Jose F Alfonso; L Fernández-Vega; C Lisa; P Fernandes; J González-Meijome; R Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-28       Impact factor: 3.117

2.  Evaluation of myopic corneal diameter with the Orbscan II Topography System.

Authors:  Yi Zha; Wangqiang Feng; Xiaohui Han; Jianqiu Cai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-02       Impact factor: 3.117

3.  Characteristics of higher-order aberrations and anterior segment tomography in patients with pathologic myopia.

Authors:  Kaori Kasahara; Naoyuki Maeda; Takashi Fujikado; Makoto Tomita; Muka Moriyama; Mutsumi Fuchihata; Kyoko Ohno-Matsui
Journal:  Int Ophthalmol       Date:  2016-11-28       Impact factor: 2.031

4.  White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Masoud Shafiee; Asieh Ehsaei
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

5.  Refractive error and ocular parameters: comparison of two SD-OCT systems.

Authors:  Lisa A Ostrin; Jill Yuzuriha; Christine F Wildsoet
Journal:  Optom Vis Sci       Date:  2015-04       Impact factor: 1.973

6.  Photopic pupil size change in myopic orthokeratology and its influence on axial length elongation.

Authors:  Meng-Jun Zhu; Li Ding; Lin-Lin Du; Jun Chen; Xian-Gui He; Shan-Shan Li; Hai-Dong Zou
Journal:  Int J Ophthalmol       Date:  2022-08-18       Impact factor: 1.645

7.  Central corneal thickness and anterior chamber depth measurement by Sirius(®) Scheimpflug tomography and ultrasound.

Authors:  J Jorge; Jl Rosado; Ja Díaz-Rey; Jm González-Méijome
Journal:  Clin Ophthalmol       Date:  2013-02-26

8.  The Role of Back Optic Zone Diameter in Myopia Control with Orthokeratology Lenses.

Authors:  Jaume Pauné; Silvia Fonts; Lina Rodríguez; Antonio Queirós
Journal:  J Clin Med       Date:  2021-01-18       Impact factor: 4.241

9.  Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes.

Authors:  Ling Wei; Wenwen He; Jiaqi Meng; Dongjin Qian; Yi Lu; Xiangjia Zhu
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-01-04       Impact factor: 4.799

10.  Refractive error and biometrics of anterior segment of eyes of healthy young university students in Japan.

Authors:  Kumiko Kato; Mineo Kondo; Maki Takeuchi; Koji Hirano
Journal:  Sci Rep       Date:  2019-10-25       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.