Literature DB >> 20010400

Intraoperative computed tomography with integrated navigation system in spinal stabilizations.

Stefan Zausinger1, Ben Scheder, Eberhard Uhl, Thomas Heigl, Dominik Morhard, Joerg-Christian Tonn.   

Abstract

STUDY DESIGN.: A prospective interventional case-series study plus a retrospective analysis of historical patients for comparison of data. OBJECTIVE.: To evaluate workflow, feasibility, and clinical outcome of navigated stabilization procedures with data acquisition by intraoperative computed tomography. SUMMARY OF BACKGROUND DATA.: Routine fluoroscopy to assess pedicle screw placement is not consistently reliable. Our hypothesis was that image-guided spinal navigation using an intraoperative CT-scanner can improve the safety and precision of spinal stabilization surgery. METHODS.: CT data of 94 patients (thoracolumbar [n = 66], C1/2 [n = 12], cervicothoracic instability [n = 16]) were acquired after positioning the patient in the final surgical position. A sliding gantry 40-slice CT was used for image acquisition. Data were imported to a frameless infrared-based neuronavigation workstation. Intraoperative CT was obtained to assess the accuracy of instrumentation and, if necessary, the extent of decompression. All patients were clinically evaluated by Odom-criteria after surgery and after 3 months. RESULTS.: Computed accuracy of the navigation system reached <2 mm (0.95 +/- 0.3 mm) in all cases. Additional time necessary for the preoperative image acquisition including data transfer was 14 +/- 5 minutes. The duration of interrupting the surgical process for iCT until resumption of surgery was 9 +/- 2.5 minutes. Control-iCT revealed incorrect screw position >/=2 mm without persistent neurologic or vascular damage in 20/414 screws (4.8%) leading to immediate correction of 10 screws (2.4%). Control-iCT changed the course of surgery in 8 cases (8.5% of all patients). The overall revision rate was 8.5% (4 wound revisions, 2 CSF fistulas, and 2 epidural hematomas). There was no reoperation due to implant malposition. According to Odom-criteria all patients experienced a clinical improvement. A retrospective analysis of 182 patients with navigated thoracolumbar transpedicular stabilizations in the preiCT era revealed an overall revision rate of 10.4% with 4.4% of patients requiring screw revision. CONCLUSION.: Intraoperative CT in combination with neuronavigation provides high accuracy of screw placement and thus safety for patients undergoing spinal stabilization. Reoperations due to implant malpositions could be completely avoided. The system can be installed into a pre-existing operating environment without need for special surgical instruments. The procedure is rapid and easy to perform without restricted access to the patient and-by replacing pre- and postoperative imaging-is not associated with an additional exposure to radiation. Multidisciplinary use increases utilization of the system and thus improves cost-efficiency relation.

Entities:  

Mesh:

Year:  2009        PMID: 20010400     DOI: 10.1097/BRS.0b013e3181b77b19

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  28 in total

1.  Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study.

Authors:  Sébastien Ruatti; C Dubois; E Chipon; G Kerschbaumer; M Milaire; A Moreau-Gaudry; J Tonetti; Ph Merloz
Journal:  Eur Spine J       Date:  2015-07-26       Impact factor: 3.134

Review 2.  Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis.

Authors:  Xiao-Tong Meng; Xiao-Fei Guan; Hai-Long Zhang; Shi-Sheng He
Journal:  Neurosurg Rev       Date:  2015-12-19       Impact factor: 3.042

3.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

4.  Accuracy and workflow of navigated spinal instrumentation with the mobile AIRO(®) CT scanner.

Authors:  Nils Hecht; Marije Kamphuis; Marcus Czabanka; Bernd Hamm; Susanne König; Johannes Woitzik; Michael Synowitz; Peter Vajkoczy
Journal:  Eur Spine J       Date:  2015-02-22       Impact factor: 3.134

5.  Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sections.

Authors:  Horst Balling; Thomas R Blattert
Journal:  Eur Spine J       Date:  2017-05-27       Impact factor: 3.134

6.  CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws.

Authors:  Albrecht Waschke; Jan Walter; Pedro Duenisch; Rupert Reichart; Rolf Kalff; Christian Ewald
Journal:  Eur Spine J       Date:  2012-09-23       Impact factor: 3.134

7.  Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques.

Authors:  Yasser Allam; J Silbermann; F Riese; R Greiner-Perth
Journal:  Eur Spine J       Date:  2012-09-25       Impact factor: 3.134

Review 8.  Techniques and accuracy of thoracolumbar pedicle screw placement.

Authors:  Varun Puvanesarajah; Jason A Liauw; Sheng-Fu Lo; Ioan A Lina; Timothy F Witham
Journal:  World J Orthop       Date:  2014-04-18

9.  Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging.

Authors:  Dimitri Tkatschenko; Paul Kendlbacher; Marcus Czabanka; Georg Bohner; Peter Vajkoczy; Nils Hecht
Journal:  Eur Spine J       Date:  2019-12-09       Impact factor: 3.134

10.  Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique.

Authors:  Yue Pan; G H Lü; Lei Kuang; Bing Wang
Journal:  Eur Spine J       Date:  2017-12-12       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.